| TERMINAL REC |
| |
Terminal Input | 1 |
|
|
Alarm Output | 0 |
|
|
Alarm Time | 030 | Sec |
|
Rec. Interval | 060 | Sec |
|
PTZ Preset | 000 |
|
|
Rec. Channel | 1 |
|
|
Rec. Quality | Normal | Full | CBR |
Period1 | 00: 00 | 24: 00 | Off |
Period2 | 00: 00 | 24: 00 | On |
All | OK | Cancel |
Terminal input connector: 1 - 8
Default: 1
Alarm output connector: 0 - 3
Default: 0 (0 indicates that there is no alarm signal output.)
Alarm time: 000 - 999 Default: 030
Rec. Interval: 030 - 999
Default: 060
Camera preset position: 000 - 256
Default: 000
Recording channel: 0 - 8
Default: 1
Picture quality: "SP Fine/Fine/Good/Normal/Extended" Default: "Normal"
Frame rate: "Full, 1/2F, 1/4F, 1/8F, 1/16F" Default: "Full"
Stream type: "CBR/VBR"
Default: "CBR" (If screen changes seem extreme, the setting made at "VBR" is preferable.)
Period: "Period1/Period2" Default: 00: 00 - 24:00
When "On" is selected for "Period1" and/or "Period2", alarm detection will be validated in the set period.
Notes:
1.When setting is completed, set "Period1" and/or "Period2" at "On".
2.For [All] operation and functions, refer to the timer recording explanation.
(4)When setting is completed, move the cursor to [OK] and press the [SET] button.
Note: When trying to stop the recording by changing the settings in the process of the terminal recording, recording will not stop immediately. The terminal recording will not stop unless time set for "Rec. Interval" has been passed. To stop the terminal recording, stop recording manually after changing the settings for the terminal recording.
Video motion detector recording (VMD REC)
(1)Press the [MENU] button.
REC & EVENT
TIMER REC
TERMINAL REC
VMD REC
RECORD LENGTH
AUDIO SELECT
(2)Move the cursor to "VMD REC" and press the [SET] but- ton.
| VMD REC |
|
|
Channel No. | 1 |
|
|
Sensitivity | 10 |
|
|
Area Setup | Set |
|
|
Alarm Output | 0 | 030 | Sec |
Rec. Interval | 060 | Sec |
|
PTZ Preset | 000 |
|
|
Rec. Quality | Normal | Full | CBR |
Period1 | 00: 00 | 24: 00 | Off |
Period2 | 00: 00 | 24: 00 | Off |
All | OK | Cancel |
Camera ID: 1-8
Default: 1
Sensitivity: 01 - 99 (01 corresponds to the maximum sensitivity.)
Default: 10
Area setup: 140 grid areas can be established inde- pendently.
Default: All areas are not selected. Alarm output connector:
Default: 0 (0 indicates that there is no alarm signal output.)
Alarm time:
Default: 030
Rec. Interval:
Default: 060
Camera preset position: 000-256
Default: 000
Picture quality: "SP Fine/Fine/Good/Normal/Extended" Default: "Normal"
37