Panasonic WJ-RT208 manual RS485 setup RS485 Setup, Data port setup Data Port Setup

Page 41

RS485 setup (RS485 SETUP)

Refer to the step (7) in 2.5.

Data port setup (DATA PORT SETUP)

The settings relating to the serial data communication can be configured on "DATA PORT SETUP" of "COMMUNICA- TION SETUP" on the "WJ-RT208 SETUP MENU".

(1)Press the [MENU] button. The "WJ-RT208 SETUP MENU" will be displayed.

WJ-RT208 SETUP MENU

SYSTEM MANAGEMENT

SEARCH

REC&EVENT SETUP

PTZ SETUP

CAMERA SETUP

COMMUNICATION SETUP

REPORT

USER INFORMATION

DATA MANAGEMENT

(2)Move the cursor onto "COMMUNICATION SETUP" and press the [SET] button.

The "COMMUNICATION SETUP" menu will be dis- played.

COMMUNICATION SETUP

NETWORK SETUP

RS485 SETUP

DATA PORT SETUP

(3)Move the cursor onto "DATA PORT SETUP" and press the [SET] button.

The "DATA PORT SETUP" menu will be displayed.

 

DATA PORT SETUP

 

 

 

 

 

 

 

 

 

 

 

Unit Address (System)

 

001

 

 

 

 

 

 

 

Baud Rate

 

 

 

9600

 

 

 

 

 

 

 

 

Data Bit

 

 

 

8

 

 

 

 

 

 

 

Parity

 

 

 

None

 

 

 

 

 

 

 

 

Stop Bit

 

 

 

1

 

 

 

 

 

 

 

Retry Timing

 

 

 

Off

 

 

 

 

 

 

Alarm Data

 

 

 

1s

 

 

 

 

 

 

Channel No.

 

 

 

Set

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OK

 

Cancel

 

 

 

 

 

 

 

 

 

(4) Configure the following setup items.

"Unit Address (System)"

A unit address (System) is a unique number assigning to PS·Data devices. The addresses must be unique to identify system devices when connecting multiple devices compatible with PS·Data.

Numbers, "001"-"099", are to be assigned as the unit addresses to the system devices.

"Baud Rate"

Select the communication speed for data transmission with a connected device from the following.

2400/4 800/9 600/19 200/38 400 bps

"Data Bit"

It is impossible to change the value for this setting.

8(bit)

"Parity"

Select a method to check a transmission error at com- munication from the following.

"None": No parity check

"Even": Even parity

"Odd": Odd parity

"Stop Bit"

Select a stop bit from the following.

1bit/2 bit

"Retry Timing"

Select a retransmission interval for when data reception is not confirmed from the following.

OFF/100 ms/200 ms/400 ms/1 000 ms

"Alarm Data"

Select a method to inform the connected controller of an event occurrence from the following.

"Off": Does not function.

"0s": Informs the controller every time an event is detected.

"1s/5s": Informs the controller when a specified time has passed after detecting an event.

"Channel No."

It is possible to assign a number to each camera chan- nel to operate cameras using the controller compatible with PS·Data.

Do the following to assign numbers to the camera chan- nels.

(1)Move the cursor onto "Channel No." and press the [SET] button.

The "Channel No." menu will be displayed.

41

Image 41
Contents Operating Instructions Lightning flash with arrowhead symbol Important Safety Instructions Limitation of Liability Disclaimer of WarrantyAbout These Operating Instructions PrecautionsTrademarks and Registered Trademarks Contents Preface FeaturesFront View Major Operating Controls & Their Functions@6Copy Connector Copy 6Cancel Button ESC↓ Down button ← Left buttonRear View Installing the Hard Disk InstallationPlaces to avoid About mountingMaster HDD of IDE port HDD connected to IDE port Slave HDD Page Basic System System Composition and ConnectionsExample for Basic System Connections Basic ConnectionWJ-RT208 Connection with RS485 CameraNetwork System Connection with External HDD For Data BackupExample for Network System Connection Direct PC ConnectionUser type Connections with any Existing Network SystemConnections with a Broadband WAN Network Connection with PS·Data systems When connecting a single unit with a controllerWhen connecting multiple units with a controller When using WJ-MP204 When using WJ-SX150RS485 Connection Pin No Signal Operation RemarksDIP Switch Setting Turning the Power On Setup ProceduresPreparation User RegistrationBasic Operation of the Menu Main menu Submenu Example Menu type2005-01-28 Cancel Turning the Power OffModification of the System Time Time & Date YYYY-MM-DD HhmmssScreen Operation OperationManual Recording Playback of Recorded ImagePlayback the record Operations for EventsEvent type Action at an eventCamera Control Cancellation of alarmPTZ Setup PTZ Select Preset Information Panning/Tilting RS485 SetupAuto function Auto Pan, etc PanasonicTo display the camera setting menu To register preset position of camerasZoom FocusOutlined functions Computer configurationControl this Unit with a PC Setting Item Description SetupSystem Management System MAN Operation for Various SettingsNtsc Picture adjustment Picture Adjust Reboot system Reboot SystemDisk information Disk Information Time & date Time & DateTimer recording Timer REC Recording & event setup REC & EventRecord search Search Terminal recording Terminal RECVideo motion detector recording VMD REC Time Per File 015 Min Cancel VMD Area Setup Area SetupSetup enabled range 005 Record length Record LengthCamera setup Camera Setup PTZ setup PTZ SetupPreset position information Preset INFORMA- Tion PTZ selection PTZ SelectTCP Communication setup CommunicaNetwork setup Network Setup Data port setup Data Port Setup RS485 setup RS485 SetupReport System LOG Event LOG Oldest Data Information Report ReportSystem log System LOG User information User Information User level setup User Level SetupEvent log Event LOG Oldest data information Oldest Data InforDo you really want to lock keyboard ? Cancel Password PasswordData management Data MANAGE- Ment Online user information Online User INFORMA- TionSearch and Playback Backup by External HDDChannel No Start End Event Only 2004-10-22 2004-10-272004-10-10 Data Management Factory Default BackupDisk Management All data will be deleted Will you continue ? CancelHDD formatting Disk FormatRecovery of hard disk index Returning the Configuration to the Default SettingsScreen in a certain channel System Screen ExplanationsOrdinary screen 9-split screen System Management System Management Setup Menu Parameters and Initial Setup ValuesTimer Recording Timer REC Recording & Event Setup REC & EventRecording Search Search Terminal Recording Terminal RECPTZ Setup PTZ Setup Communication Setup Communication Setup Camera Setup Camera SetupNetwork Setup Network Setup RS485 Setup RS485 SetupSystem Log System LOG Report ReportEvent Log Event LOG Oldest Data Information Oldest Data InformationData Management Data Management User Information User InformationOperation using the WV-CU650 Operation using the system controllerAvailable only during playback Problem Check item/remedy TroubleshootingBasic Specifications SpecificationsGeneral Input/OutputTable of Recording Length Standard AccessoriesPage Ns0306-1046 3TR004320BAA