5. Camera Setup (CAMERA SETUP)
Setting item | Default setting | Available values |
"Channel No." | 1 | 1 - 8 |
|
|
|
"CH Enable" | "On" | "Off/On" |
|
|
|
"Mask Area" | – | – |
|
|
|
"Mask Enable" | "Off" | "Off/On" |
|
|
|
"PTZ Protocol" | "PANASONIC" | "PANASONIC/TYPE 1/TYPE 2/TYPE 3/TYPE 4" |
|
|
|
"Rec. Reserve" | 000 | 000 - 200 |
|
|
|
"Channel Name" | "CH1" | "en: 10 letters, em: 5 letters" |
|
|
|
Note: The parameters for this unit can be defined for each channel.
6. Communication Setup (COMMUNICATION SETUP)
6.1 Network Setup (NETWORK SETUP)
Setting item | Default setting | Available values |
"IP Address" | 192.168.000.088 | 001.000.000.000 - 255.255.255.255 |
|
|
|
"Subnet Mask" | 255.255.255.000 | 000.000.000.000 - 255.255.255.254 |
|
|
|
"Gateway" | 192.168.000.001 | 001.000.000.000 - 255.255.255.255 |
|
|
|
"Server Port" | 2000 | 1024 - 9999 |
|
|
|
"Protocol" | "TCP" | "TCP/UDP/MCAST" |
|
|
|
"Alarm Center IP" | 192.168.000.188 | 001.000.000.000 - 255.255.255.255 |
|
|
|
"Alarm Port" | 4000 | 1024 - 9999 |
|
|
|
"Alarm Enable" | "Off" | "Off/On" |
|
|
|
"Line Speed" | "Auto Mode" | "Auto Mode/10M Half/10M Full/100M Half/100M Full" |
|
|
|
6.2 RS485 Setup (RS485 SETUP)
Setting item | Default setting | Available values | |
"Baud Rate" | 19200 | 2400/4800/9600/19200/38400 | |
|
|
|
|
"Data Bit" | 8 | – | (FIX) |
|
|
|
|
"Parity" | "None" | – | (FIX) |
|
|
|
|
"Stop Bit" | 1 | – | (FIX) |
|
|
|
|
6.3 Data port setup (DATA PORT SETUP)
Setting item | Default setting | Available values |
"Unit Address (System)" | 001 | 001 - 099 |
|
|
|
"Baud Rate" | 9600 | 2400/4800/9600/19200/38400 |
|
|
|
"Data Bit" | 8 | – (FIX) |
|
|
|
"Parity" | "None" | "None/Even/Odd" |
|
|
|
"Stop Bit" | 1 | 1/2 |
|
|
|
"Retry Timing" | "Off" | "Off/100ms/200ms/400ms/1000ms" |
|
|
|
"Alarm Data" | "1s" | "Off/0s/1s/5s" |
|
|
|
"Channel No." | - | - |
|
|
|