Panasonic WJ-RT208 manual Communication setup Communica, Network setup Network Setup, Tcp

Page 40

Channel Name: Indicates the correlation between the camera title and serial number. Channel name can be changed using the provided software.

Cautions: For the [All] operation and functions, refer to the timer recording explanation.

Notes:

1."CH Enable" of channel 1 cannot be set at "Off". During playback in channel 1, it is impossible to set up its masking area.

Mask Enable:

"On": Used to enable masking area setup. The masked area will not be displayed and recorded (Black screen will be recorded.).

"Off": The masking function is not effective.

2.During operation in sequence mode, "CH Enable" can- not be set up.

3.When the setup value for "Rec. Reserve" exceeds one day, the screen data for a maximum of "preset number of days + 4 hours" can be reserved.

4."Mask Area" can be set up with the procedures speci- fied below.

Move the cursor to "Set" of "Mask Area" and press the [SET] button. The masking area setup screen is then opened.

Mask area

Start position

End position

a)The red cursor in the above diagram indicates the starting position and the black cursor indicates the ending position. When the direction button is used, it is possible to move both the red and black cur- sors simultaneously throughout the area. It is also possible to move the black cursor only to adjust the area size. Determine if you make a control mode changeover by pressing the [SET] button, moving the red and black cursors at the same time, or mov- ing the black cursor only.

b)When Numeral 1 is pressed, the profile of the mask- ing area is displayed. When 2 is pressed, all the area is embedded.

3.1.6Communication setup (COMMUNICA-

TION SETUP)

Network setup (NETWORK SETUP)

Move the cursor to "COMMUNICATION SETUP" on "WJ- RT208 SETUP MENU" and press the [SET] button.

COMMUNICATION SETUP

NETWORK SETUP

RS485 SETUP

DATA PORT SETUP

Move the cursor to "NETWORK SETUP" and press the [SET] button.

 

NETWORK SETUP

 

 

 

 

 

IP Address

192.168.000.088

 

 

 

 

 

 

 

 

Subnet Mask

255.255.255.000

 

 

 

 

 

 

 

 

Gateway

192.168.000.088

 

 

 

 

 

 

 

 

 

 

 

Server Port

2000

 

 

 

 

 

 

 

 

Protocol

 

TCP

 

 

 

 

 

 

Alarm Center IP

192.168.000.188

 

 

 

 

 

 

 

 

Alarm Port

4000

 

 

 

 

 

 

 

 

Alarm Enable

 

Off

 

 

 

 

Line Speed

Auto Mode

 

 

 

 

 

 

 

 

 

 

 

OK

 

 

Cancel

 

 

 

 

 

 

 

 

 

 

 

IP Address: IP address given to this unit

Subnet Mask: Subnet mask for this unit

Gateway: Gateway address for this unit

Server Port: Port number of this unit

Protocol: Communication protocol

Alarm Center IP: IP address of the PC on which the Alarm Center is installed

Alarm Port: Communication port number of the alarm center, 1024 - 9999

Default: [4000] Alarm Enable: "On" or "Off"

Default: "Off"

Line Speed: Communication speed of the network card is set up to match network communications.

Notes:

1.In regard to initial setting and setup enabled range, refer to "Parameters and initial setup values for the setup menu."

2.It is necessary to restart the unit after changing the set- tings.

40

Image 40
Contents Operating Instructions Lightning flash with arrowhead symbol Important Safety Instructions Disclaimer of Warranty Limitation of LiabilityTrademarks and Registered Trademarks PrecautionsAbout These Operating Instructions Contents Features PrefaceMajor Operating Controls & Their Functions Front View6Cancel Button ESC @6Copy Connector Copy↓ Down button ← Left buttonRear View Installation Installing the Hard DiskPlaces to avoid About mountingMaster HDD of IDE port HDD connected to IDE port Slave HDD Page System Composition and Connections Basic SystemExample for Basic System Connections Basic ConnectionConnection with RS485 Camera WJ-RT208Connection with External HDD For Data Backup Network SystemExample for Network System Connection Direct PC ConnectionConnections with a Broadband WAN Network Connections with any Existing Network SystemUser type When connecting multiple units with a controller When connecting a single unit with a controllerConnection with PS·Data systems When using WJ-SX150 When using WJ-MP204Pin No Signal Operation Remarks RS485 ConnectionDIP Switch Setting Setup Procedures Turning the Power OnPreparation User RegistrationBasic Operation of the Menu Menu type Main menu Submenu ExampleTurning the Power Off 2005-01-28 CancelModification of the System Time Time & Date YYYY-MM-DD HhmmssOperation Screen OperationManual Recording Playback of Recorded ImageOperations for Events Playback the recordEvent type Action at an eventPTZ Setup PTZ Select Preset Information Cancellation of alarmCamera Control RS485 Setup Panning/TiltingAuto function Auto Pan, etc PanasonicTo register preset position of cameras To display the camera setting menuZoom FocusControl this Unit with a PC Computer configurationOutlined functions Setup Setting Item DescriptionOperation for Various Settings System Management System MANNtsc Reboot system Reboot System Picture adjustment Picture AdjustDisk information Disk Information Time & date Time & DateRecording & event setup REC & Event Timer recording Timer RECRecord search Search Terminal recording Terminal RECVideo motion detector recording VMD REC VMD Area Setup Area Setup Time Per File 015 Min CancelSetup enabled range 005 Record length Record LengthPTZ setup PTZ Setup Camera setup Camera SetupPreset position information Preset INFORMA- Tion PTZ selection PTZ SelectNetwork setup Network Setup Communication setup CommunicaTCP RS485 setup RS485 Setup Data port setup Data Port SetupSystem log System LOG Report ReportReport System LOG Event LOG Oldest Data Information User level setup User Level Setup User information User InformationEvent log Event LOG Oldest data information Oldest Data InforPassword Password Do you really want to lock keyboard ? CancelData management Data MANAGE- Ment Online user information Online User INFORMA- TionBackup by External HDD Search and PlaybackChannel No Start End Event Only 2004-10-22 2004-10-27Data Management Factory Default Backup 2004-10-10All data will be deleted Will you continue ? Cancel Disk ManagementHDD formatting Disk FormatReturning the Configuration to the Default Settings Recovery of hard disk indexOrdinary screen 9-split screen System Screen ExplanationsScreen in a certain channel Setup Menu Parameters and Initial Setup Values System Management System ManagementRecording & Event Setup REC & Event Timer Recording Timer RECRecording Search Search Terminal Recording Terminal RECPTZ Setup PTZ Setup Camera Setup Camera Setup Communication Setup Communication SetupNetwork Setup Network Setup RS485 Setup RS485 SetupReport Report System Log System LOGEvent Log Event LOG Oldest Data Information Oldest Data InformationUser Information User Information Data Management Data ManagementOperation using the system controller Operation using the WV-CU650Available only during playback Troubleshooting Problem Check item/remedySpecifications Basic SpecificationsGeneral Input/OutputStandard Accessories Table of Recording LengthPage Ns0306-1046 3TR004320BAA