Extron electronic MKP 2000 user manual Local Operation, cont’d

Page 16

Local Operation, cont’d

When an input or output outside the available range for this MKP or the connected matrix switcher is selected, the LED display shows N-A.

Viewing the last input or output tied from the MKP

Press either the Input button or the Output button.

The Input or Output LED lights.

The LED display shows the last tied input or output (depending on which LED, Input or Output, is lit).

The LED display shows the most recent input or output number entered on the numeric keys only. Ties created using other devices (other MKPs, a PC or control system, or the matrix switcher’s front panel) are not shown in the LED display.

Viewing and configuring the IP and MKP set-up parameters

To configure the MKP to operate in your LAN system, one or more of the following IP addresses and the host control port setting may need to be changed:

The MKP’s IP address (default = 192.168.254.253)

The MKP’s subnet address (default = 255.255.0.0)

The MKP’s gateway address (default = 0.0.0.0)

The target matrix switcher’s IP address (default = 0.0.0.0)

Host control port setting (pass-through or no pass- through) (default = no pass-through)

MKP’s connection setting

Primary — Controls the switcher directly.

Secondary — Controls the switcher through another MKP and its Switcher RS-232 port.

Valid IP addresses consist of four 1-, 2-, or 3-digit numeric subfields (octets) separated by dots (periods). Each octet can be numbered from 000 through 255. Leading zeroes, up to 3 digits total per octet, are optional. Values of 256 and above are invalid.

If any of the default address conflict with other equipment at your installation, you can change the IP address(es) to any valid value.

Editing the Extron IP address and other parameters while connected via the LAN port can immediately disconnect the user from the MKP. Extron recommends editing this field using the front panel or the RS-232 link

and protecting the Ethernet access to these parameters by assigning an administrator’s password to qualified and knowledgeable personnel only.

Edit these addresses and set the host control setting as follows:

1. Simultaneously press and hold the Input, Output, and Take buttons for approximately 2 seconds until the LED display changes and then release the buttons.

• The LED display shows the most-significant (left-most) octet of the MKP’s IP address (figure 3-2 on page 3-6).

• Pressing the Input button changes the IP address shown in the LED display, cycling through the various IP addresses, and then selects the host control setting, as shown in figure 3-2.

 The Input LED is lit and the Output LED is unlit when the MKP’s IP address is displayed.

 The Input LED is unlit and the Output LED is lit when the MKP’s subnet mask is displayed.

 The Input LED is blinking and the Output LED is unlit when the MKP’s gateway IP address is displayed.

 The Input LED is unlit and the Output LED is blinking when the MKP’s target matrix switcher’s IP address is displayed.

 Both the Input LED and the Output LED are lit when the host control setting is displayed.

 Both the Input LED and the Output LED are blinking when the connection priority is displayed.

• Pressing the Output button changes the octet of the selected IP address that is shown in the LED display, cycling through the four octets as shown in figure 3-2.

 No dot (period) appears in the LED display when the most-significant octet is shown.

 A dot (period) appears to the right of the left- most digit in the LED display when the second octet is shown.

 A dot (period) appears to the right of the second digit in the LED display when the third octet is shown.

 A dot (period) appears to the right of the right- most digit in the LED display when the least- significant octet is shown.

3-4

MKP 2000 Remote Control Panel • Local Operation

MKP 2000 Remote Control Panel • Local Operation

3-5

Image 16
Contents Remote Control Panel MKPPrecautions Extron’s WarrantyQuick Start Guide MKP Table of Contents MKP 2000 Remote Control Panel Table of Contents, cont’dOne IntroductionAbout the MKP 2000 Remote Control Panel RS-232 connection to the switcherEthernet connection to the switcher MKP 2000 Remote Control Panel IntroductionInstallation TwoInstallation MKP Installation OverviewUL Requirements for Wall Box Installation Installation ProceduresInstallation, cont’d Preparing the site, installing the mud ring or wall boxInstalled in a wall box To meet the UL listing requirements, this device must beMounting the MKP to the mud ring or wall box Detail aSwitch Rear Panel and Side Panel ConnectionsControl connections RS-232 cable termination11 RJ-45 connector and pinout tables TP cable terminationThree Power supply wiringLocal Operation MKP 2000 Remote Control Panel Local Operation Local OperationFront Panel Controls and Indications Front Panel OperationsLocal Operation, cont’d Viewing and configuring the IP and MKP set-up parametersViewing the last input or output tied from the MKP Host control port setting and pass-through communications Input Output TakeControl panel security lockout executive mode Rear Panel ResetsPerforming soft resets Four Performing a hard resetSIS Operation SIS Operation RS-232 LinksEthernet Link Host-to-MKP InstructionsUsing the Command/Response Table MKP Error ResponsesSIS Operation, cont’d Xxx.xx Symbol definitions for MKP SIS commandsWhere Command/response table for MKP SIS commands Cont’d SIS OperationMKP Five Html OperationHtml Operation MKP 2000 Remote Control Panel Html OperationDownload the Startup System Settings Html Operation, cont’d System StatusSwitcher Settings section IP Settings sectionHtml Operation, cont’d Port RS-232 Settings Date/Time Settings fieldsFront panel configuration lock Authorized inputs and authorized outputsHtml Operation, cont’d Passwords Firmware UpgradeFile Management Reference Data AAppendix aHtml Operation, cont’d Special Characters Reference Data SpecificationsPart Numbers Reference Data, cont’d Mounting and Cabling Specifications Electrical box cutoutPanel mount cutout template Drawn to scale may be used as a templateReference Data, cont’d Extron Comm-Link cable