HTML Operation, cont’d

Authorized inputs and authorized outputs

You can use the Authorized Inputs and Authorized Outputs drop boxes to narrow the number of inputs and outputs that are controllable from the MKP.

When creating ties from the front panel, if an input or output outside the available range for this MKP or the connected matrix switcher is selected, the LED display shows N-A.

Front panel configuration lock

Click the appropriate radio button to select the Unlocked or Locked to disable or enable the MKP control panel.

Date/Time Settings fields

The Date/Time Settings fields provide a location for viewing and setting the time functions.

If setting the time, set the local time. The Zone variable allows you to then enter the offset from Greenwich Mean Time (GMT).

The Zone field identifies the standard time zone selected and displays the amount of time, in hours and minutes, that the local time varies from the GMT international time reference.

When daylight savings time is turned on, the switcher automatically updates its internal clock between Standard Time and Daylight Savings Time in the spring and fall on the date that the time change occurs in the United States of America, Brazil, or Europe (depending on the radio button selected). When Daylight Savings Time is turned off, the switcher does not adjust its time reference.

Port (RS-232) Settings Page

The Port Settings page (figure 5-4) allows you to configure the MKP’s two (Host and Switch) RS-232 ports. Access the Port Settings page by clicking the Configuration tab and then the Port Settings link on the left side of the System Settings page.

System (IP)

Settings

Passwords

Firmware

Upgrade

Figure 5-4 — Port Settings page

The Serial Port 1 radio button selects the Host RS-232 port and the Serial Port 2 radio button selects the Switch RS-232 port. All changes made on the Port Settings must be confirmed by clicking the Submit button. Clicking the Cancel button abandons the changes.

The Extron defaults are shown below, but many switcher models have configurable ports. Extron default RS-232 port settings are:

9600 baud

no parity

8 data bits

1 stop bit

no flow control

5-8

MKP 2000 Remote Control Panel • HTML Operation

MKP 2000 Remote Control Panel • HTML Operation

5-9

Image 29
Contents MKP Remote Control PanelExtron’s Warranty PrecautionsQuick Start Guide MKP Table of Contents Table of Contents, cont’d MKP 2000 Remote Control PanelOne IntroductionRS-232 connection to the switcher About the MKP 2000 Remote Control PanelEthernet connection to the switcher MKP 2000 Remote Control Panel IntroductionTwo InstallationMKP Installation Overview InstallationUL Requirements for Wall Box Installation Installation ProceduresPreparing the site, installing the mud ring or wall box Installation, cont’dInstalled in a wall box To meet the UL listing requirements, this device must beDetail a Mounting the MKP to the mud ring or wall boxRear Panel and Side Panel Connections SwitchRS-232 cable termination Control connectionsTP cable termination 11 RJ-45 connector and pinout tablesLocal Operation Power supply wiringThree Local Operation MKP 2000 Remote Control Panel Local OperationFront Panel Controls and Indications Front Panel OperationsViewing the last input or output tied from the MKP Viewing and configuring the IP and MKP set-up parametersLocal Operation, cont’d Input Output Take Host control port setting and pass-through communicationsPerforming soft resets Rear Panel ResetsControl panel security lockout executive mode SIS Operation Performing a hard resetFour RS-232 Links SIS OperationEthernet Link Host-to-MKP InstructionsSIS Operation, cont’d MKP Error ResponsesUsing the Command/Response Table Where Symbol definitions for MKP SIS commandsXxx.xx Command/response table for MKP SIS commands MKP SIS OperationCont’d Html Operation FiveDownload the Startup MKP 2000 Remote Control Panel Html OperationHtml Operation Html Operation, cont’d System Status System SettingsHtml Operation, cont’d IP Settings sectionSwitcher Settings section Date/Time Settings fields Port RS-232 SettingsFront panel configuration lock Authorized inputs and authorized outputsFirmware Upgrade Html Operation, cont’d PasswordsFile Management Html Operation, cont’d Special Characters AAppendix aReference Data Part Numbers SpecificationsReference Data Electrical box cutout Reference Data, cont’d Mounting and Cabling SpecificationsPanel mount cutout template Drawn to scale may be used as a templateExtron Comm-Link cable Reference Data, cont’d