Reference Data

Specifications

Control/remote — keypad

Extron remote key pad control .. (2) 3.5 mm, 3-pole captive screw connectors

General

External power supply

100 VAC to 240 VAC, 50/60 Hz, external,

 

autoswitchable; to 12 VDC, 1 A, regulated

Power input requirements

12 VDC, 350 mA

Temperature/humidity

Storage: -40 to +158 °F (-40 to +70 °C) /

 

10% to 90%, noncondensing

 

Operating: +32 to +122 °F (0 to +50 °C) /

 

10% to 90%, noncondensing

Rack mount

No, but furniture/wall mountable in a

 

wall box

Enclosure type

Metal

Enclosure dimensions

 

Plate

4.5" H x 4.6" W x 0.1" D (2 gang)

 

(11.4 cm H x 11.7 cm W x 0.3 cm D)

Enclosure

2.7" H x 3.4" W x 2.0" D

 

(6.7 cm H x 8.6 cm W x 5.1 cm D)

 

Allow at least 1" (2.5 cm) D for connectors

 

and cable.

 

(Depth excludes connectors.)

Product weight

0.4 lbs (0.2 kg)

Shipping weight

2 lbs (1 kg)

Vibration

ISTA 1A in carton (International Safe

 

Transit Association)

Listings

UL, CUL

Compliances

CE, FCC Class A, VCCI, AS/NZS, ICES

MTBF

30,000 hours

Warranty

3 years parts and labor

All nominal levels are at ±10%.

Specifications are subject to change without notice.

Part Numbers

MKP 2000 Remote Control Panel

Part number

 

 

MKP 2000, black

60-682-02

 

 

MKP 2000, white

60-682-03

MKP 2000, RAL 9010 (off white)

60-682-05

Included parts

These items are included in each order for an MKP 2000:

Included parts

Part number

 

 

MKP 2000

 

 

 

12 VDC, 1A external power supply

70-055-01

MKP 2000 user’s guide

 

 

 

Two-gang mounting bracket/mud ring

 

(black, white, RAL 9010 [off white])

70-086-11, 21, 51

 

 

Installation accessories

Accessories

Part number

Two-gang “J” box 2.5” deep

980084

 

 

Cables

Cables

 

Part number

 

 

 

Comm-Link Cable:

Cut lengths:

 

 

50 feet (15.2 m)

26-461-01

 

 

 

 

100 feet (30 m)

26-461-02

 

200 feet (60 m)

26-461-03

 

 

 

 

400 feet (120 m)

26-461-04

 

Bulk spools:

 

 

500 feet (152 m)

22-119-02

 

 

 

1,000 feet (305 m) 22-119-03

 

 

 

A-2

MKP 2000 Remote Control Panel • Reference Data

MKP 2000 Remote Control Panel • Reference Data

A-3

Image 33
Contents MKP Remote Control PanelExtron’s Warranty PrecautionsQuick Start Guide MKP Table of Contents Table of Contents, cont’d MKP 2000 Remote Control PanelOne IntroductionRS-232 connection to the switcher About the MKP 2000 Remote Control PanelEthernet connection to the switcher MKP 2000 Remote Control Panel IntroductionTwo InstallationMKP Installation Overview InstallationUL Requirements for Wall Box Installation Installation ProceduresPreparing the site, installing the mud ring or wall box Installation, cont’dInstalled in a wall box To meet the UL listing requirements, this device must beDetail a Mounting the MKP to the mud ring or wall boxRear Panel and Side Panel Connections SwitchRS-232 cable termination Control connectionsTP cable termination 11 RJ-45 connector and pinout tablesPower supply wiring ThreeLocal Operation Local Operation MKP 2000 Remote Control Panel Local OperationFront Panel Controls and Indications Front Panel OperationsViewing and configuring the IP and MKP set-up parameters Local Operation, cont’dViewing the last input or output tied from the MKP Input Output Take Host control port setting and pass-through communicationsRear Panel Resets Control panel security lockout executive modePerforming soft resets Performing a hard reset FourSIS Operation RS-232 Links SIS OperationEthernet Link Host-to-MKP InstructionsMKP Error Responses Using the Command/Response TableSIS Operation, cont’d Symbol definitions for MKP SIS commands Xxx.xxWhere Command/response table for MKP SIS commands SIS Operation Cont’dMKP Html Operation FiveMKP 2000 Remote Control Panel Html Operation Html OperationDownload the Startup Html Operation, cont’d System Status System SettingsIP Settings section Switcher Settings sectionHtml Operation, cont’d Date/Time Settings fields Port RS-232 SettingsFront panel configuration lock Authorized inputs and authorized outputsFirmware Upgrade Html Operation, cont’d PasswordsFile Management AAppendix a Reference DataHtml Operation, cont’d Special Characters Specifications Reference DataPart Numbers Electrical box cutout Reference Data, cont’d Mounting and Cabling SpecificationsPanel mount cutout template Drawn to scale may be used as a templateExtron Comm-Link cable Reference Data, cont’d