HTML Operation, cont’d
IP Settings section
Unit Name field
The Unit Name field contains the
The following characters are invalid in the unit name: + ~ , @ = ‘ [ ] { } < > ’ “ ; : \ and ?.
DHCP radio buttons
The DHCP On radio button directs the MKP to ignore any entered IP addresses and to obtain its IP address from a Dynamic Host Configuration Protocol (DHCP) server (if the network is DHCP capable). The DHCP Off radio button turns DHCP off. Contact the local system administrator.
IP Address field
The IP Address field contains the IP address of the MKP. This value is encoded in the MKP’s flash memory.
Valid IP addresses consist of four
The
IP address changes can cause conflicts with other equipment. Only local system administrators should change IP addresses.
Gateway IP Address field
The Gateway IP Address field identifies the address of the gateway to the switcher’s to be used if the MKP and the server are not on the same subnet.
The gateway IP address has the same validity rules as the
MKP’s IP address. The default is 000.000.000.000.
Subnet Mask field
The Subnet Mask field is used to determine whether the MKP is on the same subnet as the switcher’s server when you are subnetting. The default is 255.255.000.000.
MAC Address field
The Media Access Control (MAC) Address is hardcoded in the MKP and cannot be changed.
Switcher Settings section
MKP Connection Priority settings
Click the appropriate radio button to select among:
•The Ethernet (IP) port to issue commands to the connected switcher
•The MKP as primary (its Switch
•The MKP as secondary (the MKP controls the switcher through another MKP)
Host Control Port settings
If the
•MKP 2000 selected — Commands received on the Host
•Pass Through selected — Commands received on the Host
If the IP radio button is selected in the Switcher Control Method box, the Host Control Port Settings selections are grayed out and unavailable.
Switcher IP settings
If the connected matrix switcher is Ethernet enabled, its IP address and password (if assigned) can be entered in these fields. The address and password are required for the MKP and the matrix switcher to communicate via their
If the Secondary MKP Connection Priority is selected, this section and all of the selections within it are labeled “Primary MKP” rather than “Switcher”.
Switcher Size settings
The MKP cannot determine the matrix size of the switcher to which it is connected. You must use the Switcher Size drop boxes to specify the number of inputs and outputs.
When creating ties from the front panel, if an input or output outside the available range for this MKP or the connected matrix switcher is selected, the LED display shows
MKP 2000 Remote Control Panel • HTML Operation | MKP 2000 Remote Control Panel • HTML Operation |