Extron electronic MKP 2000 user manual Reference Data, cont’d Mounting and Cabling Specifications

Page 34

Reference Data, cont’d

Mounting and Cabling Specifications

Electrical box cutout

Any standard box that meets the local electrical codes can be used, but boxes from different manufacturers can have different size openings. Extron recommends testing the fit of the MKP inside the electrical box and then placing the box flush against the mounting surface and tracing the cutout area.

Panel mount cutout template

Figure A-1 is a drawing that shows the dimensions for cutting a hole to accommodate the keypad circuit board for mounting the keypad on a flat surface. This type of installation can include a desk or podium, or a control panel or dashboard, where the back is protected and does not require an electrical box.

Drawn to scale; may be used as a template.

3.38”

I/O

 

2.63”

VOLUME

 

Circuit Board Box

(behind front panel)

(cut-out area should be slightly

larger)

 

 

MKP 2000

Full Size

Figure A-1 — Panel mount cutout template

A-4

MKP 2000 Remote Control Panel • Reference Data

MKP 2000 Remote Control Panel • Reference Data

A-5

Image 34
Contents Remote Control Panel MKPPrecautions Extron’s WarrantyQuick Start Guide MKP Table of Contents One MKP 2000 Remote Control PanelTable of Contents, cont’d IntroductionEthernet connection to the switcher About the MKP 2000 Remote Control PanelRS-232 connection to the switcher MKP 2000 Remote Control Panel IntroductionInstallation TwoUL Requirements for Wall Box Installation InstallationMKP Installation Overview Installation ProceduresInstalled in a wall box Installation, cont’dPreparing the site, installing the mud ring or wall box To meet the UL listing requirements, this device must beMounting the MKP to the mud ring or wall box Detail aSwitch Rear Panel and Side Panel ConnectionsControl connections RS-232 cable termination11 RJ-45 connector and pinout tables TP cable terminationThree Power supply wiringLocal Operation Front Panel Controls and Indications MKP 2000 Remote Control Panel Local OperationLocal Operation Front Panel OperationsLocal Operation, cont’d Viewing and configuring the IP and MKP set-up parametersViewing the last input or output tied from the MKP Host control port setting and pass-through communications Input Output TakeControl panel security lockout executive mode Rear Panel ResetsPerforming soft resets Four Performing a hard resetSIS Operation Ethernet Link SIS OperationRS-232 Links Host-to-MKP InstructionsUsing the Command/Response Table MKP Error ResponsesSIS Operation, cont’d Xxx.xx Symbol definitions for MKP SIS commandsWhere Command/response table for MKP SIS commands Cont’d SIS OperationMKP Five Html OperationHtml Operation MKP 2000 Remote Control Panel Html OperationDownload the Startup System Settings Html Operation, cont’d System StatusSwitcher Settings section IP Settings sectionHtml Operation, cont’d Front panel configuration lock Port RS-232 SettingsDate/Time Settings fields Authorized inputs and authorized outputsHtml Operation, cont’d Passwords Firmware UpgradeFile Management Reference Data AAppendix aHtml Operation, cont’d Special Characters Reference Data SpecificationsPart Numbers Panel mount cutout template Reference Data, cont’d Mounting and Cabling SpecificationsElectrical box cutout Drawn to scale may be used as a templateReference Data, cont’d Extron Comm-Link cable