Extron electronic MKP 2000 user manual Command/response table for MKP SIS commands

Page 23

4-8 MKP 2000 Remote Control Panel • SIS Operation

Command/response table for MKP SIS commands

Command

ASCIICommand

Response

Additional description

 

(host to MKP)

(MKP to host)

 

 

 

 

 

Front panel security lockout (executive mode)

 

 

 

 

 

 

 

 

Lock front panel

1x

Exe1

Lock front panel.

Unlock front panel

0x

Exe0

Unlock front panel.

 

 

 

 

 

Read front panel lock

x

X1

 

Read front panel lock: 1 = locked, 0 = unlocked.

 

 

 

 

 

Pass-through (RS-232 port redirect)

Configure redirect mode

Esc

 

X2

*

X3

*

X4

*

X5

CD

Cpn

X2

•Ccd

X3

,

X4

,

X5

Turn redirect mode on.

Example:

 

1*2*50*10D*CD

Cpn01•Ccd00002,00050,00000L

Esc

Disable redirect

 

*0CD

Cpn

 

 

Ccd00000,00000,00000L

Esc

 

X2

X2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

View redirect

Esc

 

X2

CD

X3

,

X4

,

X5

 

View redirect mode on/off status.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

View, information, part number, and firmware requests

Information request

I

MKP•2000

Report model name.

 

Request for part number

N

60-682-00

See Appendix A for part numbers.

 

 

 

 

 

 

 

 

 

Query firmware version

Q

 

X6

 

 

Firmware version x.xx.

 

Query verbose firmware version

0Q

 

 

 

 

Provide a detailed status of the Ethernet protocol

 

 

X7

 

 

 

 

 

 

 

 

 

firmware, the MKP controller firmware, and any

 

 

 

 

 

 

 

firmware upgrade. The firmware that is running is

 

 

 

 

 

 

 

marked by asterisk (*). A caret (^) indicates that the

 

 

 

 

 

 

 

firmware has a bad checksum or an invalid load.

 

 

 

 

 

 

 

?.?? indicates that firmware is not loaded.

 

Response description:

Ethernet protocol firmware version - controller firmware version - updated firmware version

 

 

 

 

 

 

 

 

 

Query status

S

 

X8

 

 

Voltage and temperature readings.

 

 

 

 

 

 

 

 

 

SIS Operation, cont’d

MKP 2000 Remote

Command/response table for MKP SIS commands (continued)

Command

ASCIICommand

Response

Additional description

 

(host to MKP)

(MKP to host)

 

 

 

 

 

 

 

 

 

Resets

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Absolute reset

Esc

ZQQQ

Zpq

Performs all of the reset functions as the master

 

 

 

 

 

 

 

reset, sets the MKP’s IP address to 192.168.254.254,

 

 

 

 

 

 

 

and sets the subnet mask to 255.255.0.0.

 

 

 

 

 

 

 

 

Verbose mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Set verbose mode on

Esc

X9

CV

Vrb1

The MKP reports all status changes to the device

 

 

 

 

 

 

 

that sent the command.

Read verbose mode

 

CV

 

 

 

 

Esc

X1

 

 

 

 

 

 

 

 

 

 

 

Read connection’s security level

 

CK

 

 

Password level protection assigned.

Esc

X10

 

Control Panel • SIS Operation 4-9

IP setup

Set MKP name

Set MKP name to factory default

Read MKP name

Set time/date

Read time/date

Set GMT offset

Read GMT offset

Esc

 

X11

CN

Ipn

X11

 

Assign a name to the MKP.

 

•CN

Ipn•

 

 

 

Reset the MKP’s name to the factory default.

Esc

X12

 

CN

 

 

 

 

 

 

 

Read assigned MKP name (

 

may be

 

).

Esc

 

X11

 

 

 

 

 

X11

X12

 

 

 

CT

Ipt

 

 

 

 

 

Set the time and date.

Esc

X13

X14

 

CT

 

 

 

 

 

Read the time and date.

Esc

 

X14

 

 

 

 

 

 

CZ

Ipz

 

 

The divider between hours and minutes is a period.

Esc

X15

X15

 

CZ

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Esc

 

X15

 

 

 

 

 

 

Image 23
Contents MKP Remote Control PanelExtron’s Warranty PrecautionsQuick Start Guide MKP Table of Contents Introduction MKP 2000 Remote Control PanelTable of Contents, cont’d OneMKP 2000 Remote Control Panel Introduction About the MKP 2000 Remote Control PanelRS-232 connection to the switcher Ethernet connection to the switcherTwo InstallationInstallation Procedures InstallationMKP Installation Overview UL Requirements for Wall Box InstallationTo meet the UL listing requirements, this device must be Installation, cont’dPreparing the site, installing the mud ring or wall box Installed in a wall boxDetail a Mounting the MKP to the mud ring or wall boxRear Panel and Side Panel Connections SwitchRS-232 cable termination Control connectionsTP cable termination 11 RJ-45 connector and pinout tablesLocal Operation Power supply wiringThree Front Panel Operations MKP 2000 Remote Control Panel Local OperationLocal Operation Front Panel Controls and IndicationsViewing the last input or output tied from the MKP Viewing and configuring the IP and MKP set-up parametersLocal Operation, cont’d Input Output Take Host control port setting and pass-through communicationsPerforming soft resets Rear Panel ResetsControl panel security lockout executive mode SIS Operation Performing a hard resetFour Host-to-MKP Instructions SIS OperationRS-232 Links Ethernet LinkSIS Operation, cont’d MKP Error ResponsesUsing the Command/Response Table Where Symbol definitions for MKP SIS commandsXxx.xx Command/response table for MKP SIS commands MKP SIS OperationCont’d Html Operation FiveDownload the Startup MKP 2000 Remote Control Panel Html OperationHtml Operation Html Operation, cont’d System Status System SettingsHtml Operation, cont’d IP Settings sectionSwitcher Settings section Authorized inputs and authorized outputs Port RS-232 SettingsDate/Time Settings fields Front panel configuration lockFirmware Upgrade Html Operation, cont’d PasswordsFile Management Html Operation, cont’d Special Characters AAppendix aReference Data Part Numbers SpecificationsReference Data Drawn to scale may be used as a template Reference Data, cont’d Mounting and Cabling SpecificationsElectrical box cutout Panel mount cutout templateExtron Comm-Link cable Reference Data, cont’d