PLACING ANALYZER IN SERVICE

Always install, operate, inspect and maintain this product in accordance with all applicable standards and regulations (local, state, country, fed- eral, etc.).

Keep work area clean, uncluttered, ventilated and illuminated.

Do not remove any labels. Replace any damaged label.

USING THE ANALYZER

Always wear eye protection when oper- ating or performing maintenance on this tool.

Always use Personal Protective Equip- ment appropriate to the tool used and material worked. This may include dust mask or other breathing apparatus, safety glasses, ear plugs, gloves, apron, safety shoes, hard hat and other equipment.

Keep others at a safe distance from your work area, or ensure they use appropriate Personal Protective Equip- ment.

This tool is not insulated against elec- tric shock.

This unit is for indoor use only.

Store idle units. When not in use, units should be stored in a dry, high or locked location, out of the reach of chil- dren.

Power tools can vibrate in use. Vibra- tion, repetitive motions or uncomfort- able positions may be harmful to your hands and arms. Stop using any tool if discomfort, tingling feeling or pain occurs. Seek medical advice before resuming use.

Keep body stance balanced and firm. Do not overreach when operating this tool. Anticipate and be alert for sudden changes in motion, reaction torques, or forces during start up and operation.

Ensure work pieces are secure. Use clamps or vises to hold work piece whenever possible.

Never use a damaged or malfunction- ing tool or accessory.

Maintain unit with care. Keep unit clean for better and safer performance. Fol- low instructions for changing accesso- ries. Inspect unit cords periodically and if damaged, have them repaired by an authorized service facility.

Do not operate this product in explo- sive atmospheres, such as in the pres- ence of flammable liquids, gases or dust.

Do not modify this product, safety devices, or accessories.

Do not use this product for purposes other than those recommended.

Use accessories recommended by Ingersoll-Rand for your model.

Don’t abuse the cord. Never use the cord to pull the plug from an outlet. Keep cords away from heat, oil, sharp edges or moving parts. Replace dam- aged cords immediately.

Avoid body contact with grounded sur- faces such as pipes, metal structures or other electrical products.

Stay alert, watch what you are doing and use common sense when operat- ing this product. Do not use this prod- uct while tired or under the influence of drugs, alcohol, or medication.

Do not use this product near water or other liquids.

Do not attach or place external loads on any part of the unit.

Replace battery with the same or equiv- alent type recommended by the battery manufacturer. Observe correct polarity when installing battery. Dispose of used batteries according to battery manufacturer’s instructions.

2

Image 3
Contents Operators Manual Operators Manual for Model ETA2 and ETA5 Analyzers Placing Analyzer in Service 7529eng.fm Page 3 Wednesday, November 12, 2003 857 AM Save These INSTRUCTIONS. do not Destroy Table of Contents 7529eng.fm Page 6 Wednesday, November 12, 2003 857 AM Following method is adopted throughout this manual How to use this ManualPacking List Care and Storage Battery ChargingEdit Transducer File For ETA2For ETA5 If you have chosen I/S If you have selected H/O If you have selected KEY Barcode read input for characteristic Names and commentsMeasure Mode Up to 200 readings stored Type in amount of Dip press Measure Mode Circle-Store Option Printing of stored readings from measure modeTo select this option From main menu Press Direct Direct Measure Setup 7529eng.fm Page 18 Wednesday, November 12, 2003 857 AM To set up a Characteristic ETA5 only Select Frequency Response using Then press Enter Through the available characteristics and press Direct Characteristic Mode ETA5 only7529eng.fm Page 22 Wednesday, November 12, 2003 857 AM To Store Data single characteristic ETA5 only 7529eng.fm Page 24 Wednesday, November 12, 2003 857 AM Screen will show Characteristic No 2 of ? To set up a Round ETA5 onlyTo Store Data by Round ETA5 only Set-up To set up a Master Round ETA5 onlyIf you have Next job, it will switch back when you pressTo Store Data by Master Round To return to the main menu, press Menu MenuTo Display Recorded Data on ETA5 To Display Recorded Data on ETA2To View Cp and Cpk To set this function To Erase Readings Stored in Measure ModeFrench Cp and Cpk To Erase Stored DataTo Erase Stored Data and Setups on ETA5 To Erase Characteristic SetupTo Erase Characteristic Data To Erase Round Data To Erase Round Setup InformationPrinting To print details of Setup or Analysis of Data from ETA5To print details of readings by round To print details of all characteristic setups To print details of setup and analysis of readings by roundTo print readings taken by characteristic To print details of a particular round setupThen press Print Measure To Set Date and Time Printing Data to PCTo Configure Printer Port To Set Power Off and Backlight Time DelaysTo Set Password Protection To Display Software Version NumberDisplay window Pressing Will remove the protection Screen will say Confirm password To Clear Password ProtectionTo Perform Software Reset Cm min samples To Communicate with a PC using PC Comms SoftwareExample Printout of Readings taken in Measure Mode Printout of Setup and Readings taken by Characteristic Printout of Analysis by Characteristic Printout of details of all Characteristic setups Printout of Round setup Printout of Readings taken by Characteristic Rotary and Stationary Joint Kits Deg/lbft Lbft Nominal Joint StiffnessesDwg. TPA1919 Callout Description Joint Kit Number Parts ListNot PicturedCharacteristic Glossary of TermsCpK Max Torque Value High Output Transducer H/OHorizontal Sampling Industry Standard Transducer I/SThreshold Torque Value Units of MeasureVertical Plus Prompt Code Message Explanation Error MessagesINCOR-TX OP Code ERR Dwg. TPA1822 External Connections7529eng.fm Page 62 Wednesday, November 12, 2003 857 AM 7529eng.fm Page 63 Wednesday, November 12, 2003 857 AM 7529eng.fm Page 64 Wednesday, November 12, 2003 857 AM 0102