Ingersoll-Rand ETA2, ETA5 manual Nominal Joint Stiffnesses, Deg/lbft Lbft

Page 53

7529_eng.fm Page 52 Wednesday, November 12, 2003 8:57 AM

The base plate or transducer, depending on model, should be mounted onto a rigid surface. See Figure 1 for bolt hole pattern. Place the bolt assembly just completed into the shroud and then onto the transducer or base plate. The last step is to apply the steel washer onto the bolt before applying the nut.

IMPORTANT - Grease the threads and fit the nut.

- Ensure that the threads are kept clean and lubricated.

The joint is now ready for use. Eventually the bolt and nut threads will wear and will need to be replaced. IR recommends replacing worn joints with the appropriate bolt kit that matches your joint kit model: JKS30-BKIT, JKS150-BKIT, JKS300-BKIT or JKS1000-BKIT.

Nominal Joint Stiffnesses

Joint

Rate

Max Torque

1st

2nd

Spacer(s)

Kit

 

 

 

 

Stack

Stack

mm

 

 

 

 

 

 

 

 

 

Deg/Nm

Deg/lbin

Nm

lbin

 

 

 

 

 

 

 

 

 

 

 

1/4”

50

6

5.65

50

3

3

17.1

 

 

 

 

 

 

 

 

 

30

3.4

13.5

120

6

6

11.5

 

 

 

 

 

 

 

 

 

20

2.2

21.5

190

12

12

-

 

 

 

 

 

 

 

 

 

8

0.9

28.25

250

24

-

-

 

 

 

 

 

 

 

 

 

3.5

0.4

28.25

250

-

-

11.5+12.3

 

 

 

 

 

 

 

 

 

 

Deg/lbft

 

lbft

 

 

 

 

 

 

 

 

 

 

 

3/8”

6

8

67.8

50

5

5

15.5

 

 

 

 

 

 

 

 

 

4

5.5

120

90

9

9

-

 

 

 

 

 

 

 

 

 

2

2.5

100

73.75

16

-

5

 

 

 

 

 

 

 

 

 

1

1.3

100

73.75

-

-

5+18.6+15.5

 

 

 

 

 

 

 

 

1/2”

3

4

135.6

100

5

5

19.5

 

 

 

 

 

 

 

 

 

2

2.7

220

160

9

9

-

 

 

 

 

 

 

 

 

 

1.1

1.5

271

200

9

-

23.3

 

 

 

 

 

 

 

 

 

0.4

0.55

271

200

-

-

3.9+23.3+19.5

 

 

 

 

 

 

 

 

3/4”

0.88

1.2

460

340

5

3

39.5

 

 

 

 

 

 

 

 

 

0.55

0.7

830

610

10

5

-

 

 

 

 

 

 

 

 

 

0.35

0.5

775

570

10

-

41.3

 

 

 

 

 

 

 

 

 

0.11

0.15

1017

750

-

-

39.2+41.3

 

 

 

 

 

 

 

 

Table 1

Failure to mount the base plate or transducer, depending on model, could result in injury.

52

Image 53
Contents Operators Manual Operators Manual for Model ETA2 and ETA5 Analyzers Placing Analyzer in Service 7529eng.fm Page 3 Wednesday, November 12, 2003 857 AM Save These INSTRUCTIONS. do not Destroy Table of Contents 7529eng.fm Page 6 Wednesday, November 12, 2003 857 AM Following method is adopted throughout this manual How to use this ManualPacking List Care and Storage Battery ChargingFor ETA5 Edit Transducer FileFor ETA2 If you have chosen I/S If you have selected H/O If you have selected KEY Barcode read input for characteristic Names and commentsMeasure Mode Up to 200 readings stored Type in amount of Dip press To select this option From main menu Measure Mode Circle-Store OptionPrinting of stored readings from measure mode Press Direct Direct Measure Setup 7529eng.fm Page 18 Wednesday, November 12, 2003 857 AM To set up a Characteristic ETA5 only Select Frequency Response using Then press Enter Through the available characteristics and press Direct Characteristic Mode ETA5 only7529eng.fm Page 22 Wednesday, November 12, 2003 857 AM To Store Data single characteristic ETA5 only 7529eng.fm Page 24 Wednesday, November 12, 2003 857 AM Screen will show Characteristic No 2 of ? To set up a Round ETA5 onlyTo Store Data by Round ETA5 only Set-up To set up a Master Round ETA5 onlyTo Store Data by Master Round Next job, it will switch back when you pressTo return to the main menu, press Menu Menu If you haveTo Display Recorded Data on ETA5 To Display Recorded Data on ETA2To View Cp and Cpk French Cp and Cpk To Erase Readings Stored in Measure ModeTo Erase Stored Data To set this functionTo Erase Characteristic Data To Erase Stored Data and Setups on ETA5To Erase Characteristic Setup To Erase Round Data To Erase Round Setup InformationPrinting To print details of Setup or Analysis of Data from ETA5To print details of readings by round To print details of all characteristic setups To print details of setup and analysis of readings by roundTo print readings taken by characteristic To print details of a particular round setupThen press Print Measure To Set Date and Time Printing Data to PCTo Configure Printer Port To Set Power Off and Backlight Time DelaysDisplay window Pressing Will remove the protection To Set Password ProtectionTo Display Software Version Number Screen will say Confirm password To Clear Password ProtectionTo Perform Software Reset Cm min samples To Communicate with a PC using PC Comms SoftwareExample Printout of Readings taken in Measure Mode Printout of Setup and Readings taken by Characteristic Printout of Analysis by Characteristic Printout of details of all Characteristic setups Printout of Round setup Printout of Readings taken by Characteristic Rotary and Stationary Joint Kits Deg/lbft Lbft Nominal Joint StiffnessesDwg. TPA1919 Not Parts ListPictured Callout Description Joint Kit NumberCpK CharacteristicGlossary of Terms Horizontal Sampling High Output Transducer H/OIndustry Standard Transducer I/S Max Torque ValueVertical Plus Prompt Threshold Torque ValueUnits of Measure Code Message Explanation Error MessagesINCOR-TX OP Code ERR Dwg. TPA1822 External Connections7529eng.fm Page 62 Wednesday, November 12, 2003 857 AM 7529eng.fm Page 63 Wednesday, November 12, 2003 857 AM 7529eng.fm Page 64 Wednesday, November 12, 2003 857 AM 0102