Ingersoll-Rand ETA5, ETA2 manual Barcode read input for characteristic Names and comments

Page 14

7529_eng.fm Page 13 Wednesday, November 12, 2003 8:57 AM

If you have selected KEY

Select location of decimal point using

then press Enter

To set-up another transducer press MENU

1

Select another memory (B to I) using the

keys and press Enter

To return to main menu press MENU

 

Barcode read input for characteristic

names and comments

It is possible to scan a barcode name in ETA5 at certain prompt lines. The input of a barcode is allowed at the characteristic name prompt in store characteristic, direct characteristic and edit characteristic modes. In addition it is also possible to scan a barcode in the comment field in store characteristic only. Edit characteristic and normal store behave in a slightly different man- ner to direct characteristic. The ETA5 will accept most barcode reading formats, but not all.

General Operational Method for Scanning Bar Code Data

Connect the Bar Code Reader ETA-BAR to the Printer/PC connector at the rear of the ETA5. Barcode readings can generally be taken at the prompt to input data (Characteristic name or a comment) when the flashing cursor is on the screen. This can be on a blank line or following a line of data (an existing characteristic or a comment). When the cursor is flashing, scan the code with a barcode reader and observe the screen. If the flashing cursor disappears, the code has been captured - wait a few seconds for the data to appear in the display. If the flashing cur- sor remains, re-scan the code until it is accepted.

When the data is displayed, press Enter to continue. From this point, follow the instructions

as for normal data input.

When entering data via the Bar Code Reader into a comment field, make sure you have reserved enough characters in the comment field to accept the code. If the number of charac- ters scanned in exceeds the number reserved, the ETA5 will beep and refuse to accept the data. Refer to the instructions on Configuration for more details.

13

Image 14
Contents Operators Manual Operators Manual for Model ETA2 and ETA5 Analyzers Placing Analyzer in Service 7529eng.fm Page 3 Wednesday, November 12, 2003 857 AM Save These INSTRUCTIONS. do not Destroy Table of Contents 7529eng.fm Page 6 Wednesday, November 12, 2003 857 AM How to use this Manual Following method is adopted throughout this manualPacking List Battery Charging Care and StorageFor ETA5 Edit Transducer FileFor ETA2 If you have chosen I/S If you have selected H/O Barcode read input for characteristic Names and comments If you have selected KEYMeasure Mode Up to 200 readings stored Type in amount of Dip press To select this option From main menu Measure Mode Circle-Store OptionPrinting of stored readings from measure mode Press Direct Direct Measure Setup 7529eng.fm Page 18 Wednesday, November 12, 2003 857 AM To set up a Characteristic ETA5 only Select Frequency Response using Then press Enter Direct Characteristic Mode ETA5 only Through the available characteristics and press7529eng.fm Page 22 Wednesday, November 12, 2003 857 AM To Store Data single characteristic ETA5 only 7529eng.fm Page 24 Wednesday, November 12, 2003 857 AM To set up a Round ETA5 only Screen will show Characteristic No 2 of ?To Store Data by Round ETA5 only To set up a Master Round ETA5 only Set-upTo return to the main menu, press Menu Menu Next job, it will switch back when you pressTo Store Data by Master Round If you haveTo Display Recorded Data on ETA2 To Display Recorded Data on ETA5To View Cp and Cpk To Erase Stored Data To Erase Readings Stored in Measure ModeFrench Cp and Cpk To set this functionTo Erase Characteristic Data To Erase Stored Data and Setups on ETA5To Erase Characteristic Setup To Erase Round Setup Information To Erase Round DataTo print details of Setup or Analysis of Data from ETA5 PrintingTo print details of readings by round To print details of setup and analysis of readings by round To print details of all characteristic setupsTo print details of a particular round setup To print readings taken by characteristicThen press Print Measure Printing Data to PC To Set Date and TimeTo Set Power Off and Backlight Time Delays To Configure Printer PortDisplay window Pressing Will remove the protection To Set Password ProtectionTo Display Software Version Number To Clear Password Protection Screen will say Confirm passwordTo Perform Software Reset To Communicate with a PC using PC Comms Software Cm min samplesExample Printout of Readings taken in Measure Mode Printout of Setup and Readings taken by Characteristic Printout of Analysis by Characteristic Printout of details of all Characteristic setups Printout of Round setup Printout of Readings taken by Characteristic Rotary and Stationary Joint Kits Nominal Joint Stiffnesses Deg/lbft LbftDwg. TPA1919 Pictured Parts ListNot Callout Description Joint Kit NumberCpK CharacteristicGlossary of Terms Industry Standard Transducer I/S High Output Transducer H/OHorizontal Sampling Max Torque ValueVertical Plus Prompt Threshold Torque ValueUnits of Measure Error Messages Code Message ExplanationINCOR-TX OP Code ERR External Connections Dwg. TPA18227529eng.fm Page 62 Wednesday, November 12, 2003 857 AM 7529eng.fm Page 63 Wednesday, November 12, 2003 857 AM 7529eng.fm Page 64 Wednesday, November 12, 2003 857 AM 0102