Ingersoll-Rand ETA5, ETA2 manual French Cp and Cpk, To Erase Stored Data, To set this function

Page 32

7529_eng.fm Page 31 Wednesday, November 12, 2003 8:57 AM

French Cp and Cpk

It is possible to view the French Cpk/CAM calculations as an alternative to the standard Cp and Cpk.

Readings must be a minimum of 30 samples.

To set this function:

From main menu

Press

then press

6

Press

then press

6

(Misc’)

(Software reset)

Press

 

5 times to access the Cpk Calculation screen

Use the

and

arrow keys to access option 2 ‘French Cpk/CAM’ and press Enter

Press

MENU

to confirm, screen will prompt “End of setup”

Press

MENU

to accept and exit, or

to edit

Press

MENU

to return to main menu

 

Returning to Normal Cpk calculations is done as above, selecting option 1 ‘Normal Cpk/no CAM’

For more information on Cp, Cpk and CAM, please refer to the glossary.

To Erase Stored Data

To Erase Readings Stored in Measure Mode:

From the main menu, press Y

ETA will erase all readings taken in measure mode.

31

Image 32
Contents Operators Manual Operators Manual for Model ETA2 and ETA5 Analyzers Placing Analyzer in Service 7529eng.fm Page 3 Wednesday, November 12, 2003 857 AM Save These INSTRUCTIONS. do not Destroy Table of Contents 7529eng.fm Page 6 Wednesday, November 12, 2003 857 AM How to use this Manual Following method is adopted throughout this manualPacking List Battery Charging Care and StorageFor ETA5 Edit Transducer FileFor ETA2 If you have chosen I/S If you have selected H/O Barcode read input for characteristic Names and comments If you have selected KEYMeasure Mode Up to 200 readings stored Type in amount of Dip press To select this option From main menu Measure Mode Circle-Store OptionPrinting of stored readings from measure mode Press Direct Direct Measure Setup 7529eng.fm Page 18 Wednesday, November 12, 2003 857 AM To set up a Characteristic ETA5 only Select Frequency Response using Then press Enter Direct Characteristic Mode ETA5 only Through the available characteristics and press7529eng.fm Page 22 Wednesday, November 12, 2003 857 AM To Store Data single characteristic ETA5 only 7529eng.fm Page 24 Wednesday, November 12, 2003 857 AM To set up a Round ETA5 only Screen will show Characteristic No 2 of ?To Store Data by Round ETA5 only To set up a Master Round ETA5 only Set-upNext job, it will switch back when you press To Store Data by Master RoundTo return to the main menu, press Menu Menu If you haveTo Display Recorded Data on ETA2 To Display Recorded Data on ETA5To View Cp and Cpk To Erase Readings Stored in Measure Mode French Cp and CpkTo Erase Stored Data To set this functionTo Erase Characteristic Data To Erase Stored Data and Setups on ETA5To Erase Characteristic Setup To Erase Round Setup Information To Erase Round DataTo print details of Setup or Analysis of Data from ETA5 PrintingTo print details of readings by round To print details of setup and analysis of readings by round To print details of all characteristic setupsTo print details of a particular round setup To print readings taken by characteristicThen press Print Measure Printing Data to PC To Set Date and TimeTo Set Power Off and Backlight Time Delays To Configure Printer PortDisplay window Pressing Will remove the protection To Set Password ProtectionTo Display Software Version Number To Clear Password Protection Screen will say Confirm passwordTo Perform Software Reset To Communicate with a PC using PC Comms Software Cm min samplesExample Printout of Readings taken in Measure Mode Printout of Setup and Readings taken by Characteristic Printout of Analysis by Characteristic Printout of details of all Characteristic setups Printout of Round setup Printout of Readings taken by Characteristic Rotary and Stationary Joint Kits Nominal Joint Stiffnesses Deg/lbft LbftDwg. TPA1919 Parts List NotPictured Callout Description Joint Kit NumberCpK CharacteristicGlossary of Terms High Output Transducer H/O Horizontal SamplingIndustry Standard Transducer I/S Max Torque ValueVertical Plus Prompt Threshold Torque ValueUnits of Measure Error Messages Code Message ExplanationINCOR-TX OP Code ERR External Connections Dwg. TPA18227529eng.fm Page 62 Wednesday, November 12, 2003 857 AM 7529eng.fm Page 63 Wednesday, November 12, 2003 857 AM 7529eng.fm Page 64 Wednesday, November 12, 2003 857 AM 0102