Ingersoll-Rand ETA5, ETA2 manual Example Printout of Readings taken in Measure Mode

Page 46

7529_eng.fm Page 45 Wednesday, November 12, 2003 8:57 AM

Example Printout of Readings taken in Measure Mode

MEASURE-Peak

 

 

 

Capability Results

Torque

-----------------------------------

---------------------------

No of Samples

 

200

 

Based on last

15. samples

Transducer

C I/S 75.00 Nm

 

/x

 

6.96

Nm

Serial Number:

 

99999

 

Range

 

8.30

Nm

Measurement Dir

 

Right

 

Sigma

 

2.210

 

Max Torque Value

20.00 Nm

 

Cp

 

0.754

 

Min Torque Value

10.00 Nm

 

Cpk

- 0.458

 

Thrshld Torq Val

2.00 Nm

 

Max found

 

12.65

Nm

Freq response

 

1676 Hz

 

Min found

 

4.35

Nm

Cycle end time

 

0.1 Sec

 

Readings above max

0.

 

 

 

 

 

Readings below min

13.

 

 

 

 

 

Percentage not OK

86.66 %

 

 

Date

Time

 

 

Torque

 

1

 

07/01/95

12:38:32

 

7.21

LO

2

 

07/01/95

12:38:35

 

4.87

LO

3

 

07/01/95

12:38:38

 

6.65

LO

4

 

07/01/95

12:38:40

 

6.56

LO

5

 

07/01/95

12:38:42

 

7.45

LO

6

 

07/01/95

12:38:45

 

5.76

LO

7

 

07/01/95

12:38:47

 

7.07

LO

8

 

07/01/95

12:38:49

 

12.65

 

9

 

07/01/95

12:38:52

 

9.37

LO

10

 

07/01/95

12:38:54

 

5.29

LO

11

 

07/01/95

12:38:56

 

6.09

LO

12

 

07/01/95

12:38:59

 

4.35

LO

13

 

07/01/95

12:39:01

 

5.90

LO

14

 

07/01/95

12:39:04

 

5.25

LO

15

 

07/01/95

12:39:06

 

10.03

 

45

Image 46
Contents Operators Manual Operators Manual for Model ETA2 and ETA5 Analyzers Placing Analyzer in Service 7529eng.fm Page 3 Wednesday, November 12, 2003 857 AM Save These INSTRUCTIONS. do not Destroy Table of Contents 7529eng.fm Page 6 Wednesday, November 12, 2003 857 AM How to use this Manual Following method is adopted throughout this manualPacking List Battery Charging Care and StorageFor ETA2 Edit Transducer FileFor ETA5 If you have chosen I/S If you have selected H/O Barcode read input for characteristic Names and comments If you have selected KEYMeasure Mode Up to 200 readings stored Type in amount of Dip press Printing of stored readings from measure mode Measure Mode Circle-Store OptionTo select this option From main menu Press Direct Direct Measure Setup 7529eng.fm Page 18 Wednesday, November 12, 2003 857 AM To set up a Characteristic ETA5 only Select Frequency Response using Then press Enter Direct Characteristic Mode ETA5 only Through the available characteristics and press7529eng.fm Page 22 Wednesday, November 12, 2003 857 AM To Store Data single characteristic ETA5 only 7529eng.fm Page 24 Wednesday, November 12, 2003 857 AM To set up a Round ETA5 only Screen will show Characteristic No 2 of ?To Store Data by Round ETA5 only To set up a Master Round ETA5 only Set-upTo return to the main menu, press Menu Menu Next job, it will switch back when you pressTo Store Data by Master Round If you haveTo Display Recorded Data on ETA2 To Display Recorded Data on ETA5To View Cp and Cpk To Erase Stored Data To Erase Readings Stored in Measure ModeFrench Cp and Cpk To set this functionTo Erase Characteristic Setup To Erase Stored Data and Setups on ETA5To Erase Characteristic Data To Erase Round Setup Information To Erase Round DataTo print details of Setup or Analysis of Data from ETA5 PrintingTo print details of readings by round To print details of setup and analysis of readings by round To print details of all characteristic setupsTo print details of a particular round setup To print readings taken by characteristicThen press Print Measure Printing Data to PC To Set Date and TimeTo Set Power Off and Backlight Time Delays To Configure Printer PortTo Display Software Version Number To Set Password ProtectionDisplay window Pressing Will remove the protection To Clear Password Protection Screen will say Confirm passwordTo Perform Software Reset To Communicate with a PC using PC Comms Software Cm min samplesExample Printout of Readings taken in Measure Mode Printout of Setup and Readings taken by Characteristic Printout of Analysis by Characteristic Printout of details of all Characteristic setups Printout of Round setup Printout of Readings taken by Characteristic Rotary and Stationary Joint Kits Nominal Joint Stiffnesses Deg/lbft LbftDwg. TPA1919 Pictured Parts ListNot Callout Description Joint Kit NumberGlossary of Terms CharacteristicCpK Industry Standard Transducer I/S High Output Transducer H/OHorizontal Sampling Max Torque ValueUnits of Measure Threshold Torque ValueVertical Plus Prompt Error Messages Code Message ExplanationINCOR-TX OP Code ERR External Connections Dwg. TPA18227529eng.fm Page 62 Wednesday, November 12, 2003 857 AM 7529eng.fm Page 63 Wednesday, November 12, 2003 857 AM 7529eng.fm Page 64 Wednesday, November 12, 2003 857 AM 0102