Emerson 5300, 5400 specifications Measurement Units, Volume Length

Page 29

Manual Supplement

00809-0500-4530, Rev AA October 2010

Rosemount 5300/5400 Series

Measurement Units

Table 1-17. Measurement units and corresponding input registers

Table 1-18. Conversion of Unit Code to Measurement Unit

Measurement units for the various HART slaves are stored in input registers as a Unit Code presented in Table 1-17. Conversion from Unit Code to measurement unit is given in Table 1-18 on page 1-29.

Register Name

 

Register Number

 

 

Note

Slave 1 PV Units

 

104

 

 

 

 

Slave 1 SV Units

 

108

 

See Table 1-18 for conversion from Unit

Slave 1 TV Units

 

112

 

Code to Measurement Unit.

Slave 1 FV (QV) Units

 

116

 

 

 

 

 

 

 

 

 

 

Unit Code

Measurement Unit

 

Unit Code

 

Measurement Unit

 

Volume

 

 

 

 

Length

40

US Gallon

 

 

44

 

Feet

41

Liters

 

 

45

 

Meters

42

Imperial Gallons

 

47

 

Inches

43

Cubic Meters

 

48

 

Centimeters

46

Barrels

 

 

49

 

Millimeters

111

Cubic Yards

 

 

Temperature

112

Cubic Feet

 

33

 

Degree Fahrenheit

113

Cubic Inches

 

32

 

Degree Celsius

 

 

 

 

 

 

 

 

1-29

Image 29
Contents Manual Supplement Rosemount 5300/5400 Series with Hart to Modbus ConverterExplosions could result in death or serious injury Safety MessagesWorkflow IntroductionMechanical Installation Electrical Installation Field Wiring Connections Hart + RS-485 Bus Installation casesAlternative Multidrop Connection of 5300/5400 Transmitters Star TopologyExternal Hart Devices Slaves No. of devices Approx. update rate SlavesConnect to the MA/MB terminals Establish Hart CommunicationRosemount 5300/5400 Series Connect to the Hart terminals Transmitter Configuration Using RRM to change communication parameters Modbus Communication Protocol ConfigurationModbus Setup Modbus RTU Parameter Configuration Example HMC A127 Levelmaster Communication SetupHMC A44 B4800 PO S2 HMC M2 A2 B9600 D7 PN S1 Levelmaster Parameter Configuration ExampleImplemented Functions of Levelmaster Protocol HMC M1 A246 B9600 D7 PN S1 Modbus Ascii Communication SetupRosemount 5300/5400 Series Alarm Handling Modbus Ascii Modbus RTULevelmaster Rosemount 5300/5400 Series Input Registers Common Modbus Host ConfigurationBit information in bitfield 14. Output Variables for Floating Point Format Code Rosemount 5300/5400 Series Measurement Units Volume LengthEmerson Process Management ROC800 Series Specific Modbus Host ConfigurationABB TotalFlow Emerson Process Management FloBossBristol ControlWave Micro Thermo Electron AutopilotKimray Dacc 2000/3000 ScadaPackNo 5300/5400 communication in RRM Troubleshooting No communication on RS-485 bus MA, MBNo communication with Modbus RTU protocol No communication with Modbus Ascii protocolSelect Enable Modbus Communication and click OK HMC Firmware Upgrade in Rosemount Radar MasterRosemount 5300/5400 Series Click Browse Checksum Rosemount 5300/5400 Series Specifications Rosemount 5300/5400 Series Emerson Process Management Rosemount Measurement