6. PARAMETER DESCRIPTION
(3) Display and output condition for setting alarm occurrences
|
| Alarm description | Selection | Alarm | Totali- | Pulse | Display | Alarm | |
|
| (parameter | output | output | zation | output | unit | record | |
|
|
| number) |
|
|
|
|
|
|
50 | Span > 10m/s | Span flow velocity setting |
|
|
|
|
|
|
|
is 11 m/s or more |
| Closed | Fixed | Stopped | Stopped | Alarm Mode | No | ||
|
|
|
| ||||||
|
| Span flow velocity setting |
| ||||||
51 | Span < 0.1m/s |
| (On) |
|
|
| (message) |
| |
is 0.05 m/s or less |
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
52 | TTL>10000p/s | Totalization rate is 11000 |
|
|
|
|
|
|
|
pps or more |
| Closed | Normal |
| Normal | Alarm Mode |
| ||
|
|
| Stopped | No | |||||
|
|
|
| ||||||
53 | TTL<0.0001p/s | Totalization rate is |
| (On) | operation | operation | (message) | ||
0.00005 pps or less |
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
54 | The condition |
| Closed | Fixed | Normal | Normal | Alarm Mode | No | |
limit (J11) < |
| operation | operation | (message) | |||||
|
| limit (J12)] is not satisfied. |
| (On) |
|
| |||
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
| The condition [No. 1 range |
|
|
|
|
|
|
|
55 | Multi Rng Err | < No. 2 range < No. 3 range |
| Closed | Fixed | Stopped | Stopped | Alarm Mode | No |
< No. 4 range] is not |
| ||||||||
|
| satisfied for multiple ranges. |
| (On) |
|
|
| (message) |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
| The condition [High Alarm |
|
|
|
|
|
|
|
|
| (G11) – Low Alarm (G10) > |
|
|
|
|
|
|
|
|
| H/L Alarm Hys (G14)] or the |
| Closed | Normal | Normal | Normal | Alarm Mode |
|
56 | H/L HH/LL Set | condition [High High Alarm |
| No | |||||
(G13) – Low Low Alarm |
| (On) | operation | operation | operation | (message) | |||
|
|
|
| ||||||
|
| (G12) > H/L Alarm Hys |
|
|
|
|
|
|
|
|
| (G14)] is not satisfied. |
|
|
|
|
|
|
|
|
| Mass units have been |
| Closed |
|
|
| Alarm Mode |
|
57 | Dens Set Err | selected for Base Flow Unit |
| Fixed | Stopped | Stopped | No | ||
| (On) | (message) | |||||||
|
| (C40) but density is set to 0. |
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
| Pulse rate is 11000 pps |
|
|
|
|
|
|
|
|
| or more with 50% duty |
|
|
|
|
|
|
|
60 | PLS >10000p/s | selection. | NO |
|
|
|
|
|
|
Pulse rate is 10000 pps | (G30) |
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| |
|
| or more with 0.05 ms |
|
|
|
|
|
|
|
|
| selection. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
61 | PLS > 5000p/s | Pulse rate is 5000 pps or |
|
|
|
|
|
|
|
more with 0.1 ms selection. |
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
62 | PLS > 1000p/s | Pulse rate is 1000 pps or |
|
|
|
|
|
|
|
more with 0.5 ms selection. |
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| |
|
|
|
| Closed | Normal | Normal |
| Alarm Mode |
|
63 | PLS > 500p/s | Pulse rate is 500 pps or |
| Stopped | No | ||||
| (On) | operation | operation | (message) | |||||
more with 1 ms selection. |
| ||||||||
|
|
|
|
|
|
|
|
|
|
64 | PLS > 25p/s | Pulse rate is 25 pps or |
|
|
|
|
|
|
|
more with 20 ms selection. |
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
65 | PLS > 15p/s | Pulse rate is 15 pps or |
|
|
|
|
|
|
|
more with 33 ms selection. |
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
66 | PLS > 10p/s | Pulse rate is 10 pps or |
|
|
|
|
|
|
|
more with 50 ms selection. |
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
67 | PLS > 5p/s | Pulse rate is 5 pps or |
|
|
|
|
|
|
|
more with 100 ms selection. |
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
70 | PLS<0.0001p/s | Pulse rate is 0.00005 pps |
|
|
|
|
|
|
|
or less. |
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
| Measure Mode (C20) is |
|
|
|
|
|
|
|
71 | Meas Mod Set | set to Enhanced DF |
| Closed | Fixed | Stopped | Stopped | Alarm Mode | No |
without selecting an |
| ||||||||
| (On) | (message) | |||||||
|
| optional code HF1 or |
|
|
|
|
| ||
|
| HF2. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
72 | Size Set Err | A value of 3000.1 mm or |
| Closed | Fixed | Stopped | Stopped | Alarm Mode | No |
|
| more is set for Nominal |
| (On) |
|
|
| (message) |
|
|
| Size (C32). |
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
| |
|
| The condition [Level:1< |
| Closed | Normal | Normal | Normal | Alarm Mode |
|
73 | Adh Set Err | Level:2<Level:3<Level:4] |
| No | |||||
is not satisfied for |
| (On) | operation | operation | operation | (message) | |||
|
|
|
| ||||||
|
| adhesion diagnostic level. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Occurring of | – | YES | Open | Fixed | Stopped | Stopped | Alarm Mode | No |
| any alarm from | ||||||||
| (G30) | (Off) | (message) | ||||||
| 50 through 73 |
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
Note: • Operations are performed in accordance with above table, when “Open (Off) Act” is set for G20: Alm Out Act Mode.
•
T0650.EPS