When [FAILED] has appeared for an item
Parameter | Description | |
|
| |
MAIN CPU BUS | Trouble has occurred in the microcomputer circuitry. Consult your dealer. | |
FAN | Trouble has occurred in the fan or its drive circuit. Consult your dealer. | |
OPTICS MODULE | The temperature inside the projector is high. | |
It may be that the projector is being used where the ambient temperature is | ||
TEMPERATURE | ||
high such as near a heating appliance. | ||
| ||
INPUT AIR TEMPERATURE | The input air temperature is too high. | |
It may be that the projector is being used where the ambient temperature is | ||
| high such as near a heating appliance. | |
AROUND LAMP | The temperature near the lamp has risen very high. | |
TEMPERATURE | Something may be blocking the exhaust vent. | |
LAMP REMAIN TIME | The lamp runtime has exceeded the prescribed cumulative time, and it is | |
now time to replace the lamp. | ||
| ||
LAMP STATUS | The lamp has failed to light. | |
Wait a short while for the lamp to cool off, and then turn on the power. | ||
| ||
SHUTTER | Trouble has occurred in the shutter circuitry. Consult your dealer. | |
AIR FILTER | Too much dust accumulates on the air filter. | |
Turn off the MAIN POWER switch using the procedure on page 23 and | ||
| clean the air filter (refer to page 51). | |
OPTICS MODULE TEMP.SENSOR | Trouble has occurred in the temperature detection sensor inside the | |
projector. Consult your dealer. | ||
| ||
INPUT AIR TEMP.SENSOR | Trouble has occurred in the sensor used to detect the input air temperature. | |
Consult your dealer. | ||
| ||
AROUND LAMP | Trouble has occurred in the temperature detection sensor around lamps. | |
TEMP. SENSOR | Consult your dealer. | |
BATTERY | The backup battery has been run out. Consult your dealer. | |
AIRFLOW SENSOR | Trouble has occurred in the air volume sensor. Consult your dealer. | |
COLOR WHEEL | Trouble has occurred in the color wheel or the color wheel drive circuit. | |
Consult your dealer. | ||
| ||
COVER OPEN | The lamp unit cover is not properly fitted. Check the fitting of the lamp unit | |
cover. (page 53) | ||
|
E-mail set up page
With this projector, if a problem occurs or if the lamp usage time reaches a set value, an
The user can modify the threshold temperature for sending temperature warning mail. If the temperature rises above the set value, control sends temperature warning mail.
Select “Enable” to use the
Enter the IP address or server name of the
Enter the
The user can enter the location of, for example, the installed projector so that the recipient may easily identify the originator of the
(maximum 63 characters)
The user can modify the minimum time interval of temperature warning mail. The default value is 60 minutes. In this case, the user cannot send another mail for 60 minutes after sending previous temperature warning mail even the set warning temperature is reached again.
(Continued on the next page)
41