Basic control page

This page is the first page displayed when the projector is accessed through a Web browser. To move from another page, click [Projector control], then [Basic control].

Control button

Monitor information button

E-mail set up button

Click this item, and a

Click this item, and the status of the

Click this item, and an E-mail setting

projector control page

projector is displayed.

page appears.

appears.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

POWER: Power On/Off control

SHUTTER: Shutter control

OSD (On-screen Display): display/non-display

SYSTEM: Signal System Switching

Use these to select the input signals.

Network set up button

Click this item, and a network set up page for IP address and other items appear.

Change password button

Detail control page

Click [Projector control], then [Detail control] to display the Detail control page.

On-screen status is displayed, even if the on-screen of projector is set to off.

Pressing these buttons controls the projector and updates the on-screen description on the right of the control page when control is finished.

This button updates the on-screen description on the right of the control page with the latest information.

39

Image 39
Contents Commercial Use Operating InstructionsDear Panasonic Customer Important Safety NoticePage Contents Precautions with regard to safety Always disconnect all cables before moving the projector Remove empty batteries from the remote control at onceDo not use or handle the batteries improperly Do not disassemble the lamp unitAccessories Do not use the old lamp unitDo not place the projector in extremely hot locations Precautions on handling Name and function of parts Remote controlBottom Status LED lights Front and side of the projectorRear view of the main unit Controls on rear panel Side-mounted connection terminals Using the remote control unit Effective range of remote control operationLoading dry cells Connect to the projector to use with a cable Setting projector ID number to remote controlInstallation Installation geometryProjection schemes Screen aspect ratio Projection distance by projection lensInstallation Calculation formulas for projection distance by lens types Connection Setup precautionsExample of connecting with PCs Example of connecting with AV productsProjection Powering up the projectorMaking adjustment and selection Press the I button. on the main unit or the remote controlDirect power off function Powering off the projectorHow to adjust the lens How to adjust the FOCUS, Zoom and ShiftHow to remove the projection lens Press the Shutter button again Automatic adjustmentPress the Status button on the remote control Status functionStructure of menu screens On-screen menusReturning to the previous Menu items settingResetting to the factory default Basic menu operationsAdjusting the picture Adjusting the position Digital Cinema Reality Clock PhaseZoom KeystoneClamp Position Input ResolutionXGA Mode Sxga ModeOPTION1 settings OSD Position DVI Signal LevelDVI Edid FUNC1Altitude OPTION2 settingsInstallation Projector IDLamp Select Lamp RelayRS-232C Date and Time Auto Power OFFPassword System InformationConnection example Setting the networkConnecting the PC System requirementsClick OK Using Web Browser ControlAccessing from the Web browser Password changeChange password button Basic controlDetail control Error information Monitor informationOK Normal operation Failed Occurrence of trouble When Failed has appeared for an item Parameter Description Mail set upMail set up page Continuing Authentication server set up DNS server set upPing test Adjust clock Contents of mail sentNetwork status Network configCommand Control Description Remarks Using the PJLink protocolSupported commands PJLink security authenticationControl Device Setup Setting the securityPassword Change Display SettingExamples of connection Using the serial terminalsPin assignments and signal names Communication conditions Factory settingPin assignments and control Control commandsCable specifications Connecting to a PC Computer Projector DTE specificationsIndication of lamp monitor Dismantle the air filter Cleaning and replacement of air filterProcedure of cleaning Clean the air filterAfter When to replace the Lamp unitReplacing the lamp unit LampHave a Phillips screwdriver ready ahead of time Lamp unit replacement stepsRemove the two screws securing the fan unit Lamp unit will be hot after it has been usedInstallation procedure Ceiling Mount Bracket SafeguardsImage is blurred Power doesNot turn on No imagePT-D4000U SpecificationsReplacement lamp unit Length of power cord CabinetOutside dimensions Remote control Power sourcePAL-M/PAL60 PAL/PAL-N/SECAM Compatible Signal ListInstallation dimensions diagram DimensionsTrademark Acknowledgement Concernant LA Sécurité Ne pas mettre d’objets étrangers dans le projecteur Précautions concernant la sécuritéNe pas surcharger la prise de courant Ne jamais tenter de modifier ou de démonter le projecteurNe jamais démonter la lampe Pendant un orage, ne pas toucher le projecteur ou le câbleNe pas utiliser la lampe usée Ne pas empêcher la chaleur de s’échapperPrécautions pour l’utilisation Nettoyage et maintenancePrécautions pour la manipulation Mise au rebutAprès Remplacement de la lampeMoment adéquat pour remplacer la lampe LampeProcédure de remplacement de la lampe La lampe est chaude si elle vient d’être utiliséePréparez un tournevis Phillips à l’avance Panasonic Projector Systems Company Technical SupportPanasonic Canada Inc