Tandberg Data 7000 manual Appendix 2 Connecting the system to the Switched 56 network

Page 109

TANDBERG Videoconferencing System

Appendices

Appendix 2: Connecting the system to the Switched 56 network

Using Telesync TS-256 SW56/ISDN adapter

Connecting the system to the SW56 network using a Telesync Adapter is described below.

NOTE: There are different Telesync Adapters for different configurations of SW56 networks. The network types tested with the system are SW56 2Wire and 4Wire.

Connecting

Connect the system ISDN1 cable to the BRI S/T interface on the Telesync Adapter. Connect the two SW56 cables from the Telesync adapter Line 1 and Line 2 to the SW56 network.

Circuit #1

Circuit #2

SW56

Line 1

BRI S/T

Line 2

Telesync Adapter

ISDN1

TANDBERG

Configuration of Telesync Adapter

No configuration of the Telesync Adapter is necessary.

Configuration of the system

Select network type to ‘National ISDN’.

LINE 1 SETUP

 

LINE 2 SETUP

 

NUMBER1:

program with number from the first SW56 line

NUMBER1:

number from the third SW56 line

NUMBER2:

program with number from the second SW56 line

NUMBER2:

number from the fourth SW56 line

SPID1:

program with number from the first SW56 line

SPID1:

Leave blank

SPID2

Leave blank

SPID2

Leave blank

 

 

And so on for the other lines.

How to call

Important: Use the Quick key ‘Set Restrict (56k)’ in the Quality menu to specify a restricted call (56k) when you dial a number.

Set Restrict (56k)

Example:

 

 

 

One number dialing enter:

Number:

1703111222

(56k)

Two number dialing enter:

Number:

1703111222

(56k)

 

2nd:

1703111223

 

109

Image 109 Tandberg Data 7000 Appendix 2 Connecting the system to the Switched 56 network, Using Telesync TS-256 SW56/ISDN adapter
Contents UserManual Plasma Monitors Trademarks and copyright Environmental IssuesOperator Safety Summary Contents Peripheral Equipment Advanced useAppendices 108 Index 116 TIP IntroductionLAN Menu structureAt a glance the Tandberg 7000 system Tandberg 7000 Videoconferencing SystemMonitors V.E. CameraCodec Remote control Tandberg Natural Audio module Table microphonePrecautions InstallationUnpacking Unpacking the Base Unpacking and Installing the Monitor RackInstalling the monitors InstallingInstalling the camera Connecting cables LAN cable Monitor configurationSecuring the cables Attaching the back coversMenu System configurationIsdn configuration LAN configuration System start-up Getting startedWelcome menu Basics Making a call Making and ending callsTIP Selecting / setting default quality bandwidth Selecting / setting default network End a call Answer a callCorrecting keying mistakes Press D Irectory to bring up the following menu DirectoryEdit Entry Add New EntryDelete Entry Add Site Add MultiSite EntryGeneral use Adjusting volumeView outgoing video selfview Microphone on/offDo Not Disturb / Sleep Mode Controlling the Main Camera Focusing cameraSelecting video sources Moving / zooming cameraVoice Activated Camera Positioning Selecting presets PresetsStoring presets Main cam Aux Doc cam Vcr Far end camera control FeccSending a still image Sending/receiving still imagesViewing a still image Receiving a still imageAdd Duo Video Duo VideoEnd a Duo Video call MultiSite MCU MultiSite cascading Establishing MultiSite meetings using DirectoryPress C Onnect Adding an extra site dial outAdding an extra site dial Disconnecting sites from a conferencePC SoftPresenter PC PresenterText Chat / Closed Captioning Web-interfaceStreaming Main menu Advanced useCall quality VGA ResolutionsAudio Video4CIF Advanced call qualityDuo Video Mode Presentation ModePresentations Duo Video QualityDuo Video / Still Image source Duo Video NumberAuto-display still image Still image filterAutoanswer UtilitiesFar end camera control Dual MonitorWelcome Menu Auto-PIPContinuous Presence MCU status lineMCU services Quick Menu Release floor Request floorTerminal Names View site #Chair control Audio Inputs Audio SettingsPage Audio Outputs Echo Control Page Automatic Gain Control AGC Settings Restore Audio Defaults Alert Tones & VolumeCamera Tracking Mode Video SettingsDocument Camera Brightness FocusWhitebalance Video NameVGA Settings VNC Settings Network Configuration Terminal SettingsPage Core ISDN-BRI SettingsIsdn BRI This Service has Limited Access on Some Isdn Networks Parallel dial ISDN-PRI Settings Channels automatically Page PRISM1, PRISMII, Wats Leased E1/T1 Settings External network settings 35/RS-366 cable LAN Settings Page Settings Rsvp Advanced H.323 SettingsNAT IP Settings Snmp Settings Access Code Call SettingsIncoming MCU calls Incoming telephone callsMax Call Length EncryptionNetwork Profiles Dataport configuration Page Software Options LanguageSystem info DiagnosticsChannel status TIP Call status Restore defaultsTest subsystem View current settingsInterfaces Peripheral EquipmentPage Dual Monitor Document camera Multiple controllable cameras Tracker AudioScience microphoneVCR Playback Video Cassette Recorder VCRVCR Recording Extra fixed cameras Telephone Add-OnPC applications Additional microphones Appendices Using Telesync TS-256 SW56/ISDN adapter Appendix 2 Connecting the system to the Switched 56 networkUsing CSU adapter Appendix 3 Connecting the system to PRI/T1Appendix 4 Environmental considerations Loudspeaker volumeIris control and lighting BackgroundHow to prepare a typical room for videoconferencing Guidelines for setting up videoconferencing roomsAppendix 5 Using the file system ABC Appendix 6 Access CodeAppendix 7 Declaration of Conformity Index Tandberg Videoconferencing System Index To use the dataport for PC applications