Appendices | TANDBERG Videoconferencing System |
Appendix 3: Connecting the system to PRI/T1
Using CSU adapter
Connecting the system to the ISDN network via the
NOTE: The
|
|
| Adtran |
|
|
| Codec |
| ||
Wall |
|
|
|
| ||||||
| CSU |
|
| |||||||
|
|
|
|
|
|
|
|
| ISDN E1/T1 (1) | |
|
| NET |
| CPE |
|
| ||||
|
|
|
|
| ISDN E1/T1 (2) |
| ||||
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Codec |
|
ISDN E1/T1 (1)
Connecting to Adtran T1 ESF CSU ACE
Connect the PRI cable from the Codec to the input marked CPE on the Adtran CSU (straight through category 5 cable is recommended). Connect to the network via the NET connector on the Adtran CSU. When two Codecs are cascaded, connect the second Codec to the E1/T1 port 2 on the first Codec using a T1 crossover cable.
Configuration of the system
Press MENU on the remote control. Select ‘Terminal Settings’, ‘Network’.
Select ‘Current Network: PRI’ and specify your PRI number, max. channels, cable length (between Codec and CSU) and switch type:
Number: ____________________
Max Channels: 12
Cable Length 1:
Cable Length 2:
Channel Hunting Advanced ISDN Settings
ConfigurationPreviousofMenuAdtran T1 ESFCSUACE
Note
Cascaded connection:
Remember to program numbers and MSN. Otherwise, the first codec will answer all calls.
Enter ‘2)CONFIG’ menu using SCROLL and ENTER buttons.
- Enter ‘3)TERMINAL’ menu. Check ‘1)FORMAT:ESF’, ‘2)CODE: B8ZS’ , ‘3)SET LBO:
-Go to main menu and enter ‘1)NETWORK’ menu. ‘7)SET LBO: 0.0 (According to information from Telco).
-Also, other network parameters should be set according to information from your Telco.
110