Tandberg Data 7000 manual Audio Outputs

Page 60

Advanced use

TANDBERG Videoconferencing System

Audio Outputs

Audio out 1 is intended for connection to TANDBERG Natural Audio, televisions or audio amplifiers.

Audio out 2 is intended for connection to audio recording equipment or to a telephone add-on hybrid. The signal is a mix of audio from both the far end and local end (not from Audio in 5).

Audio out 3 is intended for connection to a VCR or other recording equipment. The signal is a mix of audio from far end and local end (not from Audio in 6).

Audio Module: Select Natural Audio Module according to the type of Audio Module installed.

NOTE

NEVER CONNECT AUDIO OUT 2 OR AUDIO OUT 3 TO A LOUDSPEAKER PLACED IN THE SAME ROOM AS THE MICROPHONES CONNECTED TO THE SYSTEM. DOING THIS WILL CAUSE HOWLINGAND POSSIBLE DAMAGE TO THE SPEAKER SYSTEM.

If an output is ‘Off’, no audio will be sent to that output.

Level Settings - Outputs

Adjust the audio output levels according to the parameters of the external audio equipment connected. These levels should only be adjusted when installing new audio equipment. The default settings are correct for the TANDBERG Natural Audio module and for most consumer electronics devices (televisions, VCRs, etc.).

The volume keys on the remote control adjust the level of output 1 (the speaker output). The volume control has no effect on outputs 2 and 3.

60

Image 60
Contents UserManual Plasma Monitors Environmental Issues Trademarks and copyrightOperator Safety Summary Contents Advanced use Peripheral EquipmentAppendices 108 Index 116 Introduction TIPMenu structure LANTandberg 7000 Videoconferencing System At a glance the Tandberg 7000 systemV.E. Camera MonitorsCodec Remote control Table microphone Tandberg Natural Audio moduleInstallation PrecautionsUnpacking Unpacking and Installing the Monitor Rack Unpacking the BaseInstalling Installing the monitorsInstalling the camera Connecting cables Monitor configuration LAN cableSecuring the cables Attaching the back coversSystem configuration MenuIsdn configuration LAN configuration Getting started System start-upWelcome menu Basics Making and ending calls Making a callTIP Selecting / setting default quality bandwidth Selecting / setting default network Answer a call End a callCorrecting keying mistakes Directory Press D Irectory to bring up the following menuAdd New Entry Edit EntryDelete Entry Add MultiSite Entry Add SiteAdjusting volume General useView outgoing video selfview Microphone on/offDo Not Disturb / Sleep Mode Focusing camera Controlling the Main CameraSelecting video sources Moving / zooming cameraVoice Activated Camera Positioning Presets Selecting presetsStoring presets Far end camera control Fecc Main cam Aux Doc cam VcrSending/receiving still images Sending a still imageViewing a still image Receiving a still imageDuo Video Add Duo VideoEnd a Duo Video call MultiSite MCU Establishing MultiSite meetings using Directory MultiSite cascadingAdding an extra site dial out Press C OnnectDisconnecting sites from a conference Adding an extra site dialPC Presenter PC SoftPresenterWeb-interface Text Chat / Closed CaptioningStreaming Advanced use Main menuVGA Resolutions Call qualityAudio VideoAdvanced call quality 4CIFPresentation Mode Duo Video ModePresentations Duo Video QualityDuo Video Number Duo Video / Still Image sourceAuto-display still image Still image filterUtilities AutoanswerFar end camera control Dual MonitorAuto-PIP Welcome MenuContinuous Presence MCU status lineMCU services Quick Menu Request floor Release floorTerminal Names View site #Chair control Audio Settings Audio InputsPage Audio Outputs Echo Control Page Automatic Gain Control AGC Settings Alert Tones & Volume Restore Audio DefaultsVideo Settings Camera Tracking ModeDocument Camera Focus BrightnessWhitebalance Video NameVGA Settings VNC Settings Terminal Settings Network ConfigurationPage ISDN-BRI Settings CoreIsdn BRI This Service has Limited Access on Some Isdn Networks Parallel dial ISDN-PRI Settings Channels automatically Page PRISM1, PRISMII, Wats Leased E1/T1 Settings External network settings 35/RS-366 cable LAN Settings Page Settings Advanced H.323 Settings RsvpNAT IP Settings Snmp Settings Call Settings Access CodeIncoming MCU calls Incoming telephone callsEncryption Max Call LengthNetwork Profiles Dataport configuration Page Language Software OptionsDiagnostics System infoChannel status TIP Restore defaults Call statusView current settings Test subsystemPeripheral Equipment InterfacesPage Dual Monitor Document camera Multiple controllable cameras AudioScience microphone TrackerVideo Cassette Recorder VCR VCR PlaybackVCR Recording Telephone Add-On Extra fixed camerasPC applications Additional microphones Appendices Appendix 2 Connecting the system to the Switched 56 network Using Telesync TS-256 SW56/ISDN adapterAppendix 3 Connecting the system to PRI/T1 Using CSU adapterLoudspeaker volume Appendix 4 Environmental considerationsIris control and lighting BackgroundGuidelines for setting up videoconferencing rooms How to prepare a typical room for videoconferencingAppendix 5 Using the file system Appendix 6 Access Code ABCAppendix 7 Declaration of Conformity Index Tandberg Videoconferencing System Index To use the dataport for PC applications