Tandberg Data 7000 manual Parallel dial

Page 74

Advanced use

TANDBERG Videoconferencing System

MSN (Multiple Subscriber Number)

The use of MSN (Multiple Subscriber Number) enables you to attach different ISDN terminals, with different numbers, to the same physical ISDN telephone line. If ‘Validate Numbers’ is set to ‘On’ only calls to those numbers specified in the Line Setup menus will be answered. This service can be ordered from your telephone company.

Parallel dial

ISDN line number 12345600 / 601 / 602

Call 12345601

Line 1 Setup, Number1: 600

Validate Numbers (MSN): On

Line 1 Setup, Number1: 601

Validate Numbers (MSN): On

Line 1 Setup, Number1: 602

Validate Numbers (MSN): On

Ringing

On Channels will be dialed and connected in parallel when setting up a BONDING call.

Off Channels will be dialed one by one which may increase the dialing time.

Send Own Numbers

On The system will send its own numbers to the far end.

Off The system will not send its own numbers to the far end, but please note that the network may still send your numbers to the far end.

Sending Complete

On The system will send the ISDN message information element ‘Sending Complete’.

Off The system will not send ‘Sending Complete’.

74

Image 74
Contents UserManual Plasma Monitors Environmental Issues Trademarks and copyrightOperator Safety Summary Contents Appendices 108 Index 116 Advanced usePeripheral Equipment Introduction TIPMenu structure LANTandberg 7000 Videoconferencing System At a glance the Tandberg 7000 systemCodec V.E. CameraMonitors Remote control Table microphone Tandberg Natural Audio moduleUnpacking InstallationPrecautions Unpacking and Installing the Monitor Rack Unpacking the BaseInstalling the camera InstallingInstalling the monitors Connecting cables Securing the cables Monitor configurationLAN cable Attaching the back coversSystem configuration MenuIsdn configuration LAN configuration Welcome menu Getting startedSystem start-up Basics Making and ending calls Making a callTIP Selecting / setting default quality bandwidth Selecting / setting default network Correcting keying mistakes Answer a callEnd a call Directory Press D Irectory to bring up the following menuDelete Entry Add New EntryEdit Entry Add MultiSite Entry Add SiteView outgoing video selfview Adjusting volumeGeneral use Microphone on/offDo Not Disturb / Sleep Mode Selecting video sources Focusing cameraControlling the Main Camera Moving / zooming cameraVoice Activated Camera Positioning Storing presets PresetsSelecting presets Far end camera control Fecc Main cam Aux Doc cam VcrViewing a still image Sending/receiving still imagesSending a still image Receiving a still imageDuo Video Add Duo VideoEnd a Duo Video call MultiSite MCU Establishing MultiSite meetings using Directory MultiSite cascadingAdding an extra site dial out Press C OnnectDisconnecting sites from a conference Adding an extra site dialPC Presenter PC SoftPresenterWeb-interface Text Chat / Closed CaptioningStreaming Advanced use Main menuAudio VGA ResolutionsCall quality VideoAdvanced call quality 4CIFPresentations Presentation ModeDuo Video Mode Duo Video QualityAuto-display still image Duo Video NumberDuo Video / Still Image source Still image filterFar end camera control UtilitiesAutoanswer Dual MonitorContinuous Presence Auto-PIPWelcome Menu MCU status lineMCU services Quick Menu Terminal Names Request floorRelease floor View site #Chair control Audio Settings Audio InputsPage Audio Outputs Echo Control Page Automatic Gain Control AGC Settings Alert Tones & Volume Restore Audio DefaultsDocument Camera Video SettingsCamera Tracking Mode Whitebalance FocusBrightness Video NameVGA Settings VNC Settings Terminal Settings Network ConfigurationPage ISDN-BRI Settings CoreIsdn BRI This Service has Limited Access on Some Isdn Networks Parallel dial ISDN-PRI Settings Channels automatically Page PRISM1, PRISMII, Wats Leased E1/T1 Settings External network settings 35/RS-366 cable LAN Settings Page Settings Advanced H.323 Settings RsvpNAT IP Settings Snmp Settings Incoming MCU calls Call SettingsAccess Code Incoming telephone callsNetwork Profiles EncryptionMax Call Length Dataport configuration Page Language Software OptionsChannel status DiagnosticsSystem info TIP Restore defaults Call statusView current settings Test subsystemPeripheral Equipment InterfacesPage Dual Monitor Document camera Multiple controllable cameras AudioScience microphone TrackerVCR Recording Video Cassette Recorder VCRVCR Playback Telephone Add-On Extra fixed camerasPC applications Additional microphones Appendices Appendix 2 Connecting the system to the Switched 56 network Using Telesync TS-256 SW56/ISDN adapterAppendix 3 Connecting the system to PRI/T1 Using CSU adapterIris control and lighting Loudspeaker volumeAppendix 4 Environmental considerations BackgroundGuidelines for setting up videoconferencing rooms How to prepare a typical room for videoconferencingAppendix 5 Using the file system Appendix 6 Access Code ABCAppendix 7 Declaration of Conformity Index Tandberg Videoconferencing System Index To use the dataport for PC applications