Tandberg Data 7000 manual Appendix 5 Using the file system

Page 113

TANDBERG Videoconferencing System

Appendices

Appendix 5: Using the file system

It is possible to access a file system within the TANDBERG system by using ftp:

DOS-window: ftp <IP-address of codec>, or

Web-browser: ftp:// <IP-address of codec>

Description of the different files

all.prm

- all settings in the system (including directory)

dir.prm

- directory entries

event.log - logs fault sitations etc.

sw.pkg

- the system software

Description of the different folders

user

- a folder to be used for custom logos etc.

remote

- a folder used for software upgrade of the far end TANDBERG system

What can be done by using the file system?

·software upgrade of the far end TANDBERG system (B3 or above) via ISDN

·upload of custom logos

Software upgrade

·Connect to the system you want to upgrade using ISDN.

·Copy the software file to a folder on your harddisk.

·Open a DOS-window and go to this folder.

·Type ftp <IP-address of your local codec).

·Enter password: <Release Key of far end system>

·Go to the remote folder, type “cd remote”

·Upload the software file, type put <s0xxxxxx.pkg>

·Wait until the following is shown:

226 Closing data connection.

5437569 bytes sent in 808.01 seconds (6.73 Kbytes/sec)

ftp>

· Restart the far end codec.

The far end system should now be upgraded. For further information, please contact your TANDBERG representative.

Custom logos

· Go to the folder where your logo is located.

NOTE: Logo max size: 320x200, or max. 64000 pixels and must be in jpg-format. If the file is too large, no logo will be displayed.

·Type ftp <IP-address of your local codec).

·Go to the user folder, type “cd user”

·Upload the logo, type put <startup.jpg>

The new logo will be displayed the next time you restart your system.

113

Image 113
Contents UserManual Plasma Monitors Trademarks and copyright Environmental IssuesOperator Safety Summary Contents Appendices 108 Index 116 Advanced usePeripheral Equipment TIP IntroductionLAN Menu structureAt a glance the Tandberg 7000 system Tandberg 7000 Videoconferencing SystemCodec V.E. CameraMonitors Remote control Tandberg Natural Audio module Table microphoneUnpacking InstallationPrecautions Unpacking the Base Unpacking and Installing the Monitor RackInstalling the camera InstallingInstalling the monitors Connecting cables LAN cable Monitor configurationSecuring the cables Attaching the back coversMenu System configurationIsdn configuration LAN configuration Welcome menu Getting startedSystem start-up Basics Making a call Making and ending callsTIP Selecting / setting default quality bandwidth Selecting / setting default network Correcting keying mistakes Answer a callEnd a call Press D Irectory to bring up the following menu DirectoryDelete Entry Add New EntryEdit Entry Add Site Add MultiSite EntryGeneral use Adjusting volumeView outgoing video selfview Microphone on/offDo Not Disturb / Sleep Mode Controlling the Main Camera Focusing cameraSelecting video sources Moving / zooming cameraVoice Activated Camera Positioning Storing presets PresetsSelecting presets Main cam Aux Doc cam Vcr Far end camera control FeccSending a still image Sending/receiving still imagesViewing a still image Receiving a still imageAdd Duo Video Duo VideoEnd a Duo Video call MultiSite MCU MultiSite cascading Establishing MultiSite meetings using DirectoryPress C Onnect Adding an extra site dial outAdding an extra site dial Disconnecting sites from a conferencePC SoftPresenter PC PresenterText Chat / Closed Captioning Web-interfaceStreaming Main menu Advanced useCall quality VGA ResolutionsAudio Video4CIF Advanced call qualityDuo Video Mode Presentation ModePresentations Duo Video QualityDuo Video / Still Image source Duo Video NumberAuto-display still image Still image filterAutoanswer UtilitiesFar end camera control Dual MonitorWelcome Menu Auto-PIPContinuous Presence MCU status lineMCU services Quick Menu Release floor Request floorTerminal Names View site #Chair control Audio Inputs Audio SettingsPage Audio Outputs Echo Control Page Automatic Gain Control AGC Settings Restore Audio Defaults Alert Tones & VolumeDocument Camera Video SettingsCamera Tracking Mode Brightness FocusWhitebalance Video NameVGA Settings VNC Settings Network Configuration Terminal SettingsPage Core ISDN-BRI SettingsIsdn BRI This Service has Limited Access on Some Isdn Networks Parallel dial ISDN-PRI Settings Channels automatically Page PRISM1, PRISMII, Wats Leased E1/T1 Settings External network settings 35/RS-366 cable LAN Settings Page Settings Rsvp Advanced H.323 SettingsNAT IP Settings Snmp Settings Access Code Call SettingsIncoming MCU calls Incoming telephone callsNetwork Profiles EncryptionMax Call Length Dataport configuration Page Software Options LanguageChannel status DiagnosticsSystem info TIP Call status Restore defaultsTest subsystem View current settingsInterfaces Peripheral EquipmentPage Dual Monitor Document camera Multiple controllable cameras Tracker AudioScience microphoneVCR Recording Video Cassette Recorder VCRVCR Playback Extra fixed cameras Telephone Add-OnPC applications Additional microphones Appendices Using Telesync TS-256 SW56/ISDN adapter Appendix 2 Connecting the system to the Switched 56 networkUsing CSU adapter Appendix 3 Connecting the system to PRI/T1Appendix 4 Environmental considerations Loudspeaker volumeIris control and lighting BackgroundHow to prepare a typical room for videoconferencing Guidelines for setting up videoconferencing roomsAppendix 5 Using the file system ABC Appendix 6 Access CodeAppendix 7 Declaration of Conformity Index Tandberg Videoconferencing System Index To use the dataport for PC applications