Tandberg Data 7000 manual MultiSite MCU

Page 40

General use

TANDBERG Videoconferencing System

 

 

MultiSite (MCU)

The system has a built-in multipoint conference unit (MCU), MultiSite, which has the capability to establish meetings with up to 4 video sites (5 if at least one site is a telephone call, ISDN/analogue/mobile).

The video calls in a conference must be connected using the same bandwidth.

A conference can consist of any combination of ISDN/

LAN sites.

It is possible to have telephone meetings with up to 5 participants.

The MultiSite supports both Voice Switched and Continuous Presence mode (see ‘MCU Services’ in ‘Advanced use’ for description of these modes).

Establishing a conference is done by first making a call to one site. When a call is established with the first site, the other sites are connected one by one.

It is possible to either dial out to the sites or the sites can dial in to the MultiSite.

TIP

SEE ‘UTILITIES’, ‘CONTINUOUS PRESENCETO CHANGE MODE.

MULTISITE - WHICH QUALITY CAN BE USED ON EACH SITE?

 

 

 

4 SITES

4 SITES

3 SITES

3 SITES +

P-TO-P +

(2MBPS VERSION)

 

+ 1 PHONE

 

1-2PHONES

1-3PHONES

BRI (768 KBPS)

256 KBPS

192

384

320

512

PRI-E1(1920 K)

512

512

768

768

1472

PRI-T1(1472 K)

384

384

512

512

1152

LAN (2304 K)

768

768 *

1152

1152 *

1920 *

 

 

 

 

 

 

MIX ISDN/LAN EXAMPLE: IF 4 SITES ARE CONNECTED, TWO LAN SITES AND ONE ISDN SITE CAN BE CONNECTED ON 512 KBPS (2MBPS VERSION). NOTE - 4 SITES INDICATES YOURSELF + THREE OTHER SITES.

*- REQUIRES 1-3 ISDN CHANNELS AVAILABLE.

NOTE

WHEN MIXING ISDN AND LAN SITES, THE

TOTAL BANDWIDTH

LIMITATION IS THE SAME AS FOR THE ISDN BANDWIDTH.

* - Optional feature.

40

Image 40
Contents UserManual Plasma Monitors Environmental Issues Trademarks and copyrightOperator Safety Summary Contents Peripheral Equipment Advanced useAppendices 108 Index 116 Introduction TIPMenu structure LANTandberg 7000 Videoconferencing System At a glance the Tandberg 7000 systemMonitors V.E. CameraCodec Remote control Table microphone Tandberg Natural Audio modulePrecautions InstallationUnpacking Unpacking and Installing the Monitor Rack Unpacking the BaseInstalling the monitors InstallingInstalling the camera Connecting cables Monitor configuration LAN cableSecuring the cables Attaching the back coversSystem configuration MenuIsdn configuration LAN configuration System start-up Getting startedWelcome menu Basics Making and ending calls Making a callTIP Selecting / setting default quality bandwidth Selecting / setting default network End a call Answer a callCorrecting keying mistakes Directory Press D Irectory to bring up the following menuEdit Entry Add New EntryDelete Entry Add MultiSite Entry Add SiteAdjusting volume General useView outgoing video selfview Microphone on/offDo Not Disturb / Sleep Mode Focusing camera Controlling the Main CameraSelecting video sources Moving / zooming cameraVoice Activated Camera Positioning Selecting presets PresetsStoring presets Far end camera control Fecc Main cam Aux Doc cam Vcr Sending/receiving still images Sending a still image Viewing a still image Receiving a still imageDuo Video Add Duo VideoEnd a Duo Video call MultiSite MCU Establishing MultiSite meetings using Directory MultiSite cascadingAdding an extra site dial out Press C OnnectDisconnecting sites from a conference Adding an extra site dialPC Presenter PC SoftPresenterWeb-interface Text Chat / Closed CaptioningStreaming Advanced use Main menuVGA Resolutions Call qualityAudio VideoAdvanced call quality 4CIFPresentation Mode Duo Video ModePresentations Duo Video QualityDuo Video Number Duo Video / Still Image sourceAuto-display still image Still image filterUtilities AutoanswerFar end camera control Dual MonitorAuto-PIP Welcome MenuContinuous Presence MCU status lineMCU services Quick Menu Request floor Release floorTerminal Names View site #Chair control Audio Settings Audio InputsPage Audio Outputs Echo Control Page Automatic Gain Control AGC Settings Alert Tones & Volume Restore Audio DefaultsCamera Tracking Mode Video SettingsDocument Camera Focus BrightnessWhitebalance Video NameVGA Settings VNC Settings Terminal Settings Network ConfigurationPage ISDN-BRI Settings CoreIsdn BRI This Service has Limited Access on Some Isdn Networks Parallel dial ISDN-PRI Settings Channels automatically Page PRISM1, PRISMII, Wats Leased E1/T1 Settings External network settings 35/RS-366 cable LAN Settings Page Settings Advanced H.323 Settings RsvpNAT IP Settings Snmp Settings Call Settings Access CodeIncoming MCU calls Incoming telephone callsMax Call Length EncryptionNetwork Profiles Dataport configuration Page Language Software OptionsSystem info DiagnosticsChannel status TIP Restore defaults Call statusView current settings Test subsystemPeripheral Equipment InterfacesPage Dual Monitor Document camera Multiple controllable cameras AudioScience microphone TrackerVCR Playback Video Cassette Recorder VCRVCR Recording Telephone Add-On Extra fixed camerasPC applications Additional microphones Appendices Appendix 2 Connecting the system to the Switched 56 network Using Telesync TS-256 SW56/ISDN adapterAppendix 3 Connecting the system to PRI/T1 Using CSU adapterLoudspeaker volume Appendix 4 Environmental considerationsIris control and lighting BackgroundGuidelines for setting up videoconferencing rooms How to prepare a typical room for videoconferencingAppendix 5 Using the file system Appendix 6 Access Code ABCAppendix 7 Declaration of Conformity Index Tandberg Videoconferencing System Index To use the dataport for PC applications