Tandberg Data 7000 manual Channels automatically

Page 76

Advanced use

TANDBERG Videoconferencing System

 

Below is a list of common ISDN-PRI/T1 switches.

 

 

 

Type

Manufacturer

PRI Switch Type setting

 

 

ATT 4 ESS

AT&T

AT&T ISDN

 

 

ATT 5 ESS

AT&T/Lucent

AT&T ISDN or National ISDN*

 

 

DMS 100

Northern Telecom

National ISDN

 

 

DMS 250

Northern Telecom

National ISDN

 

 

* Settings will depend on configuration of the switch. PRI Switch Type is not changed when Restoring Defaults.

 

 

 

 

 

 

Channel Hunting

Max Channels

Maximum number of channels the unit may use at any given time.

Low Channel

The lowest numbered B-channel that may be used by the unit when selecting channels

 

for outgoing calls.

High Channel

The highest numbered B-channel that may be used by the unit when selecting channels

 

for outgoing calls.

Search

Specifies where the system will start searching for available B-channels for outgoing

 

calls.

 

 

 

 

 

 

 

 

Channel hunting is normally used in conjunction with PRI daisy-chaining with

 

 

 

 

 

Codec 1

 

 

 

 

 

Low Channel: 10

TANDBERG units in the daisy-chain. If only TANDBERG units are used in the

 

 

 

 

 

High Channel: 20

daisy-chain, default setting should be used, as these units will find available B-

 

 

 

 

 

Max Channel: 6

 

 

 

 

 

channels automatically.

PRI line

 

PRI 1

 

 

 

 

 

 

Max Channels may be used for PRIs that are provisioned for a lower number of

 

 

 

 

 

PRI 2

 

 

 

 

 

channels.

 

 

 

 

 

 

 

 

 

 

 

 

Max Channels may be used as mechanism to ensure that there is bandwidth

 

 

 

 

 

 

 

 

 

 

 

 

available to codecs further down the chain when Daisy-Chaining.

 

 

Codec 2

 

Channels: 1-9

 

 

or

 

 

 

 

 

will be available for

‘High Channel’, ‘Low Channel’ and ‘Search’ may be used for PRIs provisioned with

 

 

PBX

 

the codec/PBX

 

 

 

 

 

 

specific requirements for B-channel usage.

76

Image 76
Contents UserManual Plasma Monitors Environmental Issues Trademarks and copyrightOperator Safety Summary Contents Peripheral Equipment Advanced useAppendices 108 Index 116 Introduction TIPMenu structure LANTandberg 7000 Videoconferencing System At a glance the Tandberg 7000 systemMonitors V.E. CameraCodec Remote control Table microphone Tandberg Natural Audio modulePrecautions InstallationUnpacking Unpacking and Installing the Monitor Rack Unpacking the BaseInstalling the monitors InstallingInstalling the camera Connecting cables Monitor configuration LAN cableSecuring the cables Attaching the back coversSystem configuration MenuIsdn configuration LAN configuration System start-up Getting startedWelcome menu Basics Making and ending calls Making a callTIP Selecting / setting default quality bandwidth Selecting / setting default network End a call Answer a callCorrecting keying mistakes Directory Press D Irectory to bring up the following menuEdit Entry Add New EntryDelete Entry Add MultiSite Entry Add SiteAdjusting volume General useView outgoing video selfview Microphone on/offDo Not Disturb / Sleep Mode Focusing camera Controlling the Main CameraSelecting video sources Moving / zooming cameraVoice Activated Camera Positioning Selecting presets PresetsStoring presets Far end camera control Fecc Main cam Aux Doc cam VcrSending/receiving still images Sending a still imageViewing a still image Receiving a still imageDuo Video Add Duo VideoEnd a Duo Video call MultiSite MCU Establishing MultiSite meetings using Directory MultiSite cascadingAdding an extra site dial out Press C OnnectDisconnecting sites from a conference Adding an extra site dialPC Presenter PC SoftPresenterWeb-interface Text Chat / Closed CaptioningStreaming Advanced use Main menuVGA Resolutions Call qualityAudio VideoAdvanced call quality 4CIFPresentation Mode Duo Video ModePresentations Duo Video QualityDuo Video Number Duo Video / Still Image sourceAuto-display still image Still image filterUtilities AutoanswerFar end camera control Dual MonitorAuto-PIP Welcome MenuContinuous Presence MCU status lineMCU services Quick Menu Request floor Release floorTerminal Names View site #Chair control Audio Settings Audio InputsPage Audio Outputs Echo Control Page Automatic Gain Control AGC Settings Alert Tones & Volume Restore Audio DefaultsCamera Tracking Mode Video SettingsDocument Camera Focus BrightnessWhitebalance Video NameVGA Settings VNC Settings Terminal Settings Network ConfigurationPage ISDN-BRI Settings CoreIsdn BRI This Service has Limited Access on Some Isdn Networks Parallel dial ISDN-PRI Settings Channels automatically Page PRISM1, PRISMII, Wats Leased E1/T1 Settings External network settings 35/RS-366 cable LAN Settings Page Settings Advanced H.323 Settings RsvpNAT IP Settings Snmp Settings Call Settings Access CodeIncoming MCU calls Incoming telephone callsMax Call Length EncryptionNetwork Profiles Dataport configuration Page Language Software OptionsSystem info DiagnosticsChannel status TIP Restore defaults Call statusView current settings Test subsystemPeripheral Equipment InterfacesPage Dual Monitor Document camera Multiple controllable cameras AudioScience microphone TrackerVCR Playback Video Cassette Recorder VCRVCR Recording Telephone Add-On Extra fixed camerasPC applications Additional microphones Appendices Appendix 2 Connecting the system to the Switched 56 network Using Telesync TS-256 SW56/ISDN adapterAppendix 3 Connecting the system to PRI/T1 Using CSU adapterLoudspeaker volume Appendix 4 Environmental considerationsIris control and lighting BackgroundGuidelines for setting up videoconferencing rooms How to prepare a typical room for videoconferencingAppendix 5 Using the file system Appendix 6 Access Code ABCAppendix 7 Declaration of Conformity Index Tandberg Videoconferencing System Index To use the dataport for PC applications