Connecting cables

All cables needed in standard configuration are connected to the codec. Connect these cables to the other parts of the system:

1. Power cable

Connect the system power cable to an electrical distribution socket.

2. Monitor cables

Connect the 2 BNC (Y/C input at the monitor), the 9 pin DSUB and the power cable to the input on your monitor. You will find the cables coiled up in the base (for dual monitor systems there will be a coil for each monitor).

3. Microphone cable

Connect the microphone cable to the microphone.

4. Camera cable

Connect the camera and the camera cable.

5a. ISDN cables - using BRI interface

Connect the ISDN cables to the ISDN sockets (S/T-interface) provided by the service provider. Your main number will be the number associated with the socket to which ISDN cable number 1 is connected.

NOTE

THE SYSTEM DOES NOT HAVE A BUILT-IN NETWORK TERMINATOR. IF YOUR WALL SOCKET PROVIDES YOU WITH AN ISDN U-INTERFACE,YOU WILL NEED AN NT1 BETWEEN YOUR SYSTEM AND YOUR ISDN LINE, SEE APPENDIX 1.

5b. ISDN cable - using the PRI interface

If you are using the PRI interface, the E1/T1 cable should be connected to a CSU (Channel Service Unit). You will need a CSU between your system and the PRI line from your network provider, see Appendix 3.

5c. Other networks - using the External Network interface

If you are using other networks, please refer to ‘External Network Settings’ and ‘Appendix 2’.

16

Image 16
Contents UserManual Plasma Monitors Environmental Issues Trademarks and copyrightOperator Safety Summary Contents Peripheral Equipment Advanced useAppendices 108 Index 116 Introduction TIPMenu structure LANTandberg 7000 Videoconferencing System At a glance the Tandberg 7000 systemMonitors V.E. CameraCodec Remote control Table microphone Tandberg Natural Audio modulePrecautions InstallationUnpacking Unpacking and Installing the Monitor Rack Unpacking the BaseInstalling the monitors InstallingInstalling the camera Connecting cables Monitor configuration LAN cableSecuring the cables Attaching the back coversSystem configuration MenuIsdn configuration LAN configuration System start-up Getting startedWelcome menu Basics Making and ending calls Making a callTIP Selecting / setting default quality bandwidth Selecting / setting default network End a call Answer a callCorrecting keying mistakes Directory Press D Irectory to bring up the following menuEdit Entry Add New EntryDelete Entry Add MultiSite Entry Add SiteAdjusting volume General useView outgoing video selfview Microphone on/offDo Not Disturb / Sleep Mode Focusing camera Controlling the Main CameraSelecting video sources Moving / zooming cameraVoice Activated Camera Positioning Selecting presets PresetsStoring presets Far end camera control Fecc Main cam Aux Doc cam VcrSending/receiving still images Sending a still imageViewing a still image Receiving a still imageDuo Video Add Duo VideoEnd a Duo Video call MultiSite MCU Establishing MultiSite meetings using Directory MultiSite cascadingAdding an extra site dial out Press C OnnectDisconnecting sites from a conference Adding an extra site dialPC Presenter PC SoftPresenterWeb-interface Text Chat / Closed CaptioningStreaming Advanced use Main menuVGA Resolutions Call qualityAudio VideoAdvanced call quality 4CIFPresentation Mode Duo Video ModePresentations Duo Video QualityDuo Video Number Duo Video / Still Image sourceAuto-display still image Still image filterUtilities AutoanswerFar end camera control Dual MonitorAuto-PIP Welcome MenuContinuous Presence MCU status lineMCU services Quick Menu Request floor Release floorTerminal Names View site #Chair control Audio Settings Audio InputsPage Audio Outputs Echo Control Page Automatic Gain Control AGC Settings Alert Tones & Volume Restore Audio DefaultsCamera Tracking Mode Video SettingsDocument Camera Focus BrightnessWhitebalance Video NameVGA Settings VNC Settings Terminal Settings Network ConfigurationPage ISDN-BRI Settings CoreIsdn BRI This Service has Limited Access on Some Isdn Networks Parallel dial ISDN-PRI Settings Channels automatically Page PRISM1, PRISMII, Wats Leased E1/T1 Settings External network settings 35/RS-366 cable LAN Settings Page Settings Advanced H.323 Settings RsvpNAT IP Settings Snmp Settings Call Settings Access CodeIncoming MCU calls Incoming telephone callsMax Call Length EncryptionNetwork Profiles Dataport configuration Page Language Software OptionsSystem info DiagnosticsChannel status TIP Restore defaults Call statusView current settings Test subsystemPeripheral Equipment InterfacesPage Dual Monitor Document camera Multiple controllable cameras AudioScience microphone TrackerVCR Playback Video Cassette Recorder VCRVCR Recording Telephone Add-On Extra fixed camerasPC applications Additional microphones Appendices Appendix 2 Connecting the system to the Switched 56 network Using Telesync TS-256 SW56/ISDN adapterAppendix 3 Connecting the system to PRI/T1 Using CSU adapterLoudspeaker volume Appendix 4 Environmental considerationsIris control and lighting BackgroundGuidelines for setting up videoconferencing rooms How to prepare a typical room for videoconferencingAppendix 5 Using the file system Appendix 6 Access Code ABCAppendix 7 Declaration of Conformity Index Tandberg Videoconferencing System Index To use the dataport for PC applications