Kathrein cap910 Installation of Turntable, Variant with Cable Gland Underneath the Turntable

Page 14

INSTALLATION AND CONNECTION

Before starting adhesive work, note that the optimum processing temperature of materials to be glued and the sealant is between +15 °C and +25 °C. Prepare all necessary fastening elements and tools.

Prepare the tube of adhesive sealant in accordance with the instructions enclosed with the tube.

Remove the roof gland (Fig. A) and apply the adhesive sealant evenly to the underside of the roof gland flange.

Replace the roof gland in the drilled hole and press it firmly against the roof of the vehicle.

Apply the adhesive sealant evenly to the underside of the mounting plate, completely covering the area within the circular groove (Fig. D).

This area of the vehicle roof must be completely coated with adhesive in order to achieve the necessary bonding force.

Place the mounting plate onto the roof of the vehicle, as you did previously when marking out the drilled holes.

Make sure that the arrow on the mounting plate points forward in the direction of travel. The fastening holes must be perfectly aligned with the prepared holes in the roof.

Fasten the mounting plate in place with the prepared screws, evenly tightening all ten screws across the diagonals.

Note: The adhesive sealant used is capable of filling small gaps caused by the curvature of the vehicle roof. However, you should ensure that the mounting plate is not bent by tightening the screws.

Remove any adhesive sealant that leaks out at the sides with a clean cloth or if necessary with Sikaflex® remover (available from specialist dealers). Do not use cleaning agents or thinners containing solvents, as this could damage the sealant applied under the mounting plate. Use only cleansing paste and water to clean your hands.

Secure the cable gland from inside the vehicle by tightening the ribbed nut supplied (Fig. A).

Note that the curing of the adhesive sealant depends on the ambient temperature and the humidity. Final strength is reached only after approx. five days. However, this need not restrict further installation work, since the mounting plate is held in place by the tightened screws.

INSTALLATION OF TURNTABLE

VARIANT WITH CABLE GLAND UNDERNEATH THE TURNTABLE

Lay the cables supplied with the turntable (2 x coaxial cables and 1 x power supply cable) into the mounting plate as indicated by the markings on the mounting plate (see Fig. E1), and feed the remaining lengths of cable through the roof gland into the interior of the motor home/caravan.

14

Image 14
Contents CAP General Company Address and Accredited RepresentativeMobiset 4 CAP 910 Components / Scope of Delivery Product PackageContents Installation Manual Contents Operating Manual Proper USE Proper USE USE for the Intended PurposeAdhesive sealant Safety Instructions Important NotesEssential information Power supply, fusing Road Traffic Licensing Regulations StVZOChecks before commencing a journey Required Tools and Equipment Installation and ConnectionSelecting the Installation Location Unpacking and PreparationDirection of travel Installation Steps Figure C Not included Installation of Turntable Variant with Cable Gland Underneath the TurntableFigure E1 Master coaxial cable marked red Version with External Cable Gland FIG. F Installation and Connection Installation of the UFS 940SW Selection of a Suitable Installation LocationPreparations Important Instructions for Installation Rear of the receiver Front of the receiver Installation Laying Cables and Connecting the Turntable Installation and Connection Connection Example for 12 V Battery Connection Receiver. There is no restriction onReception Range / Footprint Dismantling Address of the Service CentreDismantling for Servicing ESCSafety Instructions Manual Lowering to Park PositionManual Lowering Technical Specifications Direction of travelComposition/data on components Sikaflex 291 Safety Data SheetMaterials/preparation and company designation Potential hazardsHandling and storage Measures for fire fightingMeasures if inadvertently released Exposure limitation and personal protective equipmentPhysical and chemical characteristics Stability and reactivityDisposal instructions Toxicology data SensitisationEcological data Transport dataOther data Sikaflex 291 Technical Data Sheet Sikaflex-291 IkaflexChemical Stability CAP CAP 910 Operating ManualImportant Information for CAP 910 Before Setup Remote ControlFirst Installation Hdmi Video System Local time offset UTC Automatic clock change summer/winter timeCalling UP the CAP Menu CAP Menu Turntable Antenna SettingsResetting the CAP System Turntable Antenna Reset All satellite positions found by a search will be deletedElevation Inputting the CAP GPS PositionTo Move the Antenna Manually Move to the Azimuth Rotate the Antenna Stop on SignalLNB TILT/SKEW Elevation Border and Elevation Offset CAP SettingsMove CAP to Park Position Search SpeedRestore Factory Settings Countdown for the Search StartAlignment Satellite Search Channel Satellite SELECTION/PROGRAMMING the Timer Channel Selection from the Channel ListTimer Programming Channel Selection from the Channel List Sorted by SatelliteChange of Location Change of Location Park Parking the TurntableSpecial Messages from the Turntable System Protection MessagesSpecial Messages from the Turntable Messages Arising from Software Problems Further MessagesTimer function is currently not yet available in CAP mode Declaration of Conformity Disposal Instructions Spent batteries are special waste