Whirlpool LI30LA/W10463244A Electrical Requirements, Planning the Installation

Page 5

Planning the Installation

Planning the Makeup Air Switch Duct installation

This makeup air kit can only be used with vented range hoods. The makeup air kit must match the vent transition size for your range hood.

Planning the Motorized Damper installation

Planning the installation first requires selecting the most appropriate installation approach. The following illustrations offer suggestions for the most effective installation approach by considering a few important factors.

Typical Installations

Installations will vary according to the location in the home where the motorized damper is installed and which makeup air kit is used. The following illustrations can be used as a reference guide for your installation. Always comply with all governing codes and ordinances.

NOTE: The 10" (25.4 cm) round Makeup Air Kit must be installed with 2 independent incoming air supply ducts. Use the

2 motorized dampers supplied with the kit (1 each, in the incoming fresh air supply ducts).

Motorized Damper Connected to Return Side of Central Duct System

F

G

D

 

 

H

 

I

C

J

 

B

 

A

 

E

 

A. Range hood

F. Return air central system

B. Vent transition

G. Motorized damper

C. Makeup air switch duct

H. Wall or roof

D. Range hood exhaust

I. Wall/roof cap

E. HVAC system

J. Outside air

Motorized Damper and Outside Air Connected Directly to a Ceiling, Floor or Wall Register

 

E

D

 

 

F

 

G

C

H

B

 

A

 

A. Range hood

E. Motorized damper

B. Vent transition

F. Wall or roof

C. Makeup air switch duct

G. Wall/roof cap

D. Range hood exhaust

H. Outside air

Electrical Requirements

Observe all governing codes and ordinances.

Ensure that the electrical installation is adequate and in conformance with National Electrical Code, ANSI/NFPA 70 (latest edition), or CSA Standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No. 0-M91 (latest edition) and all local codes and ordinances.

If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate.

A copy of the above code standards can be obtained from:

National Fire Protection Association

1 Batterymarch Park

Quincy, MA 02169-7471

CSA International

8501 East Pleasant Valley Road

Cleveland, OH 44131-5575

A 120 volt, 60 Hz., AC only, 15-amp, fused electrical circuit is required.

If the house has aluminum wiring, follow the procedure below:

1.Connect a section of solid copper wire to the pigtail leads.

2.Connect the aluminum wiring to the added section of copper wire using special connectors and/or tools designed and UL listed for joining copper to aluminum.

Follow the electrical connector manufacturer's recommended procedure. Aluminum/copper connection must conform with local codes and industry accepted wiring practices.

Wire sizes must conform to the requirements of the National Electrical Code, ANSI/NFPA 70 (latest edition), or CSA Standards C22. 1-94, Canadian Electrical Code, Part 1 and C22.2 No. 0-M91 (latest edition) and all local codes and ordinances.

A UL or CSA listed strain relief must be provided at each end of the power supply cable/conduit (at the junction boxes).

5

Image 5
Contents DE Ventilación Rectangulares Table of Contents/Índice/Table des matièresVent System Safety Table of ContentsÍndice Table DES MatièresImportant Safety Instructions Location Requirements Installation RequirementsTools and Parts Typical Installations Planning the InstallationPlanning the Makeup Air Switch Duct installation Planning the Motorized Damper installationInstall Makeup Air Switch Duct Installation Instructions10 25.4 cm Round Makeup Air Switch Duct From kit W10446917 Prepare LocationTo Remove and Install Motorized Damper Terminal Box Cover Install Motorized DamperMake Electrical Connection Under-Cabinet Mount Range Hood ModelsMake the Electrical Connection Makeup Air Kit MaintenanceCheck Operation SE12R a Wiring DiagramCanada Assistance or ServiceU.S.A Items Excluded from Warranty Year Limited Warranty Parts only Labor not IncludedThis warranty does not cover Date for in-warranty serviceSu seguridad y la seguridad de los demás es muy importante Seguridad DEL Sistema DE VentilaciónInstrucciones Importantes DE Seguridad Requisitos de ubicación Requisitos DE InstalaciónHerramientas y piezas Instalaciones típicas Requisitos eléctricosPlanificación de la instalación Preparación de la ubicación Instrucciones DE InstalaciónInstalación del conducto conmutador de Aire de complemento Modelos de campana de cocina para montaje en muro o islaModelos de campana de cocina para montaje debajo de armarios Instalación del regulador de tiro MotorizadoHaga la conexión del suministro eléctrico Haga la conexión del suministro eléctricoMantenimiento del juego de aire de Complemento Verifique el funcionamientoMicrointerruptor de activación Diagrama DE CableadoEn los EE.UU Ayuda O Servicio TécnicoWhirlpool Exclusión DE Garantías Implícitas Sécurité DES Circuits DE VentilationImportantes Instructions DE Sécurité Exigences demplacement Exigences DinstallationOutils et pièces Outils nécessairesInstallations typiques Planification de linstallationPlanification de linstallation du clapet motorisé Spécifications électriquesModèles de hottes à installation murale ou en îlot Instructions D’INSTALLATIONPréparation de lemplacement Modèles de hottes placard Installation du clapet motoriséEffectuer le raccordement électrique Raccordement électriqueContrôle du fonctionnement Maintenance de lensemble dair de CompensationDébit dair de compensation Schéma DE CâblageAu Canada Assistance OU ServiceSi vous avez besoin de pièces de rechange Pour plus d’assistanceComposer le W10463244A