A&D HV-G Series Basic Operation, Turning the Scale On/Off & Basic Weighing, Memo

Page 17

7 Basic Operation

7.1 Turning the Scale On/Off & Basic Weighing

7.1.1 Type V or Type L with AC adaptor

Step

1

Connect the scale to a ground point.

Step

2

Ensure that the pan is empty.

Step

3

Confirm that local voltage and receptacle type fit your scale.

Step

4

The scale turns on/off using the

 

 

switch alternately.

ON/OFF

Step

5

Check the accuracy of weighing. If you calibrate the scale, perform it after

 

 

allowing the scale to warm up for 30 minutes.

Step

6

Press the

 

switch to display zero. (With nothing on the pan.)

ZERO

Step

7

Place something on the pan gently.

Step

8

You can read the weight after the stability mark is displayed.

Step

9

Remove the item from the pan.

Step 10

Turn the scale off using the

 

 

switch.

ON/OFF

Memo

With the power cord connected, type V consumes only sufficient power for standby status after turning off the scale.

With the AC adaptor connected, type L consumes only the power of the AC adaptor after turning off the scale.

HV-G Instruction Manual Page 16

Image 17
Contents HV-G Series Contents Page Compliance with FCC rules ComplianceOutline and Features Unpacking Type Products Accessories Accessories and Options listOptions List Order code or option name AccessoriesPrecautions for Storing the Scale Precautions for Installing the ScalePrecautions for Operating the Scale Installing the Scale Installing the Batteries for Type L Names OFF Display and SymbolsPage Switches Page Memo Basic OperationTurning the Scale On/Off & Basic Weighing Type L with Batteries Semi-Automatic Tare Input by Weighing Tare and Net DisplayWeighing Range Weighing RangeOperation and Performance Products Weighing RangeMode Switch Changing Unit & Mode Storing a Unit Mass Counting ModeCounting the number of articles Storing a 100% Mass Percentage ModeReading Percentage Function table Meaning & Purpose Operation and SwitchesAccumulation Function Preparation Setting Parameters Example Operation and Performance ExamplesComparator Sign Comparator FunctionComparison Condition Function table Meaning and PurposeAccumulation function f6 Step If one Has Been selected, press Case Full/Dribble Batch Function Hold ComparatorFull/Dribble batch sub-function Parameter and display an item of the full/dribble Switch to display the HI Function Table Meaning and purpose Simple batch function Simple Batch FunctionPreparation Setting Parameters Operation and Performance Examples Calibration Adjusting the Scale Gravity Acceleration Table Gravity Acceleration Correction Complete Calibration ProcedureCalibration of the Zero Point Function Table Procedure for Setting Parameters15.2 Parameter List Function or full/dribble batch function Display Meaning and purposePrinting condition when using option OP-06 for type Function to hold the current display value. When 16 RS-232C Serial Data Interface Format Data FormatFormat Preparation and Performance Examples Stream ModeTare Command ModeCancel of tare Upper limit value Preset tareFinal value Preparation Setting Parameters 17.1 RS-232C / Relay output / Buzzer OP-03 Pin connections Pin No Signal name Direction DescriptionOptions 17.2 RS-422 / RS-485 / Relay output OP-04 Pin No Signal name Direction DescriptionInstalling OP-04 Communication Format Lower limit value ZeroAccumulation data output Reset of Accumulation data and numberAccumulation count output Final valueConsumables SpecificationInternal Printer for Type V OP-06 Installation DisassemblyPerformance Check HV-G series SpecificationsDimensions Page Check Points Before Calling Maintenance MaintenanceRepair This situation Confirm these items