Caution
The comparison of the full/dribble batch function is not reversible (One way se- quence). If the display value becomes less than the final value after the value reached a predetermined target value, neither HI or LO is on.
The parameters of the upper limit value (HI) and the final value (HI) use the same memory. The parameters of the lower limit value (LO) and the zero band (LO) use the same memory.
The upper/lower comparator function, the simple batch function and the full/dribble batch function cannot be used at the same time because these parameters use common memory.
Set the zero band greater than the tare value.
Operation
Pressing the SET switch, the scale starts the batch process.
Selecting a parameter from f10 0 or f10 2 of the full/dribble batch
Parameter List and Word Definition
The “gross” is a total weighing value, no tare value is subtracted.
The “net” is a measurement value with the tare value subtracted from the gross. The “zero band” means the zero detection level.
The “zero point” is the fundamental starting point to weighing.
Comparator
Function tableMeaning and purpose
f6 9 Full/Dribble batch function
Full/Dribble batch sub-function
| Function table |
| Meaning and purpose | |||||||
|
| f10 | 0 |
| Reaching final value and pressing the F switch the current process is | |||||
|
|
|
|
| finished. |
| ||||
|
| f10 | 1 |
| Reaching the final value and displaying the stability mark the current | |||||
|
|
|
|
| process is finished automatically. |
| ||||
|
| f10 | 2 |
| Pressing the |
|
| switch the scale automatically tares and starts the | ||
|
|
|
| SET | ||||||
|
|
|
|
| full/dribble batch process. Reaching final value and pressing the F switch, | |||||
|
|
|
|
| the current process is finished. | |||||
|
| f10 | 3 |
| Pressing the |
| switch the scale automatically tares and starts the |
| ||
|
|
| SET |
| ||||||
|
|
|
|
| full/dribble batch process. Reaching the final value and displaying the | |||||
|
|
|
|
| stability mark the current process is finished. | |||||
Hold |
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| |||
Function table |
| Meaning and purpose | ||||||||
|
| f12 | 0 |
| The hold function is not used |
|
| |||
|
|
|
|
|
|
|
|
|
|
|