A&D HV-G Series instruction manual Type L with Batteries

Page 18

7.1.2 Type L with Batteries

Step

1

Install six new batteries. Refer to “5.1. Installing the batteries for Type L”.

Step

2

Ensure that the pan is empty.

Step

3

The scale turns on/off using the

 

switch alternately.

ON/OFF

Step

4

Check the accuracy of weighing. If you calibrate the scale, perform it after

 

 

warming up the scale for 30 minutes.

Step

5

Press the

 

switch to display zero. (With nothing on the pan.)

ZERO

Step

6

Place something on the pan gently.

Step

7

You can read the weight value after the stability mark is displayed.

Step

8

Remove the item from the pan.

Step

9

Turn the scale off using the

 

 

switch.

ON/OFF

Caution

Replace used dry cells with six new ones when BATT is displayed. Battery life is affected by the environmental temperature.

Remove batteries from the display unit when the scale is not to be used for a long time. The batteries may leak and cause damage.

HV-G Instruction Manual Page 17

Image 18
Contents HV-G Series Contents Page Compliance Compliance with FCC rulesOutline and Features Unpacking Accessories and Options list Type Products AccessoriesOrder code or option name Accessories Options ListPrecautions for Installing the Scale Precautions for Operating the ScalePrecautions for Storing the Scale Installing the Scale Installing the Batteries for Type L Names Display and Symbols OFFPage Switches Page Basic Operation Turning the Scale On/Off & Basic WeighingMemo Type L with Batteries Tare and Net Display Semi-Automatic Tare Input by WeighingOperation and Performance Weighing RangeWeighing Range Products Weighing RangeMode Switch Changing Unit & Mode Counting Mode Storing a Unit MassCounting the number of articles Percentage Mode Storing a 100% MassReading Percentage Operation and Switches Accumulation FunctionFunction table Meaning & Purpose Preparation Setting Parameters Operation and Performance Examples ExampleComparison Condition Comparator FunctionComparator Sign Function table Meaning and PurposeAccumulation function f6 Step If one Has Been selected, press Case Full/Dribble Batch Function Comparator Full/Dribble batch sub-functionHold Parameter and display an item of the full/dribble Switch to display the HI Simple Batch Function Function Table Meaning and purpose Simple batch functionPreparation Setting Parameters Operation and Performance Examples Calibration Adjusting the Scale Gravity Acceleration Table Complete Calibration Procedure Gravity Acceleration CorrectionCalibration of the Zero Point Procedure for Setting Parameters Function Table15.2 Parameter List Display Meaning and purpose Function or full/dribble batch functionPrinting condition when using option OP-06 for type Function to hold the current display value. When 16 RS-232C Serial Data Interface Data Format FormatFormat Stream Mode Preparation and Performance ExamplesCommand Mode Cancel of tareTare Preset tare Upper limit valueFinal value Preparation Setting Parameters Pin connections Pin No Signal name Direction Description Options17.1 RS-232C / Relay output / Buzzer OP-03 Pin No Signal name Direction Description 17.2 RS-422 / RS-485 / Relay output OP-04Installing OP-04 Communication Format Zero Lower limit valueAccumulation count output Reset of Accumulation data and numberAccumulation data output Final valueSpecification Internal Printer for Type V OP-06Consumables Disassembly InstallationPerformance Check Specifications HV-G seriesDimensions Page Repair MaintenanceCheck Points Before Calling Maintenance This situation Confirm these items