event log

Reserved for amplifiers, this feature is a protection circuitry event log which can only be accessed when the target amplifier is in standby. The protection circuit shuts down the amplifier or channel if it overheats or if its output could damage your speakers. The event log details the circumstances surrounding the amp going into protection and should be referred to in situations that require the intervention of your dealer or Classé customer support.

The log can report the following events interpreted as follows:

+ve slow blo trip & -ve slow blo trip — The average current has reached the safe operating limit.

+ve fast blo trip & -ve fast blo trip — The peak current has reached the safe operating limit.

over temperature trip — The unit temperature has reached the safe operating limit.

DC protection trip — The DC output level has reached the safe operating limit.

Communication failure — There has been a loss of communication between the amp’s system monitoring sensors.

AC line trip — The power supply has reached the limits of the amp’s safe operating range.

These events are rare and generally occur due to issues that are external to the amp. They should be interpreted positively. The amp is doing what it’s designed

to do.

61

Image 61
Contents Surround Sound Processor SSP-800/CT-SSPClass Important Safety Instructions Contents PlayLink NameWelcome to the Classé family IntroductionExceptional Design Features Page Unpacking your SSP Unpacking and PlacementNON-RACK-MOUNT Installation for SSP Tighten to In-lbs 0.96 N-m Warm-up/break-in period Operating voltage Voltage protection Front Panels Standby/On Button and Status IndicatorTouchscreen Menu On/Off ButtonAudio Mute Control IR windowVolume Control Knob Serial number Rear PanelComposite Video Inputs Hdmi Inputs Component Video InputsComponent Video Output Hdmi OutputsDigital Audio Inputs Coaxial Digital Audio Inputs OpticalDigital Audio Output Optical Digital Audio Output Coaxial10 7.1-Channel Analog Audio Inputs 11 2-Channel Balanced Analog Audio InputsIR Output IR InputTrigger Outputs USB Port 17 RS-232 Port19 10-Channel Analog Outputs CAN-Bus Input and OutputAC Power Cord Input Main Power On/Off SwitchBasic Functions Remote ControlAudio Processing Functions Input Sel Selection ButtonVolume Control & Mute Buttons Preset Config Configuration ButtonNavigation & Menu Buttons Function Keys F1 to F4Step Initial SetupChoose the appropriate cables Connect all source components to the SSP rear panel Terminals to black terminals Power up the system Understanding Surround Sound Name Dolby TrueHD Post-processingSource selection Using the SSP-800/CT-SSPName Description Mode selectionDTS Neo6 Cinema System trims ControlsConfiguration select Menu System Volume setup System setupMax volume Startup volume IR setup Automation Mute setup Name Input setupAudio Configuration Triggers Use Video Next inputProfiles Room EQ Configuration Name Distances Use Speakers LevelsSpeakers available Auxiliary channels Black level Teach IR Display setupBrightness Timeout Language OSD on screen display Dolby/DTS Colors VolumeDolby Pro Logic DTS Neo6 Dolby Volume Important note on Fkey use Remote FkeysVersion info Sensors FeaturesClassé Delta Series Products Hardware setupCategory 5 Network Cables CAN-Bus Terminator Using CAN-Bus CAN-Bus shared features Configuration Operate AC status Status PlayLink Amp info Event log Everything appears to be powered on, but there is no sound TroubleshootingThere is no sound and the Standby LED is not lit Only one speaker seems to be playing IR remote control does not seem to functionThere is a hum coming out of the speakers There is a hum coming from the SSPVoltage Protection Circuit Input factory defaults Care & MaintenanceOverall dimensions SpecificationsNet weight Shipping weightSSP-800 Dimensions CT-SSP Dimensions Installation Worksheet Lachine, Quebec Canada H8T 1B3