SPEED CONTROL PROBLEMS

to Figure on page. 34). The relay indicator should light up. If it does, go to step #4. If the relay indicator does not light up, the relay assembly circuit board must be replaced. Replace the relay assembly circuit board and retest the machine.

4.You must check the cable assembly for continuity if the relay indicator lit up when you jumped tabs #1 and #5.

a.Unplug the main cable from the position labeled J1 on the relay assembly circuit board. Disconnect the console cable from the back of the console. Set your multimeter to the continuity check mode; on most meters, this will be the resistance or ohms setting.

b.Place one lead of the multimeter on pin #1 at the console connector end of the console cable (refer to Wiring Diagram). Place the other lead on pin #1 at the end of the main cable you disconnected from the relay assembly circuit board. You will get a reading of near zero ohms if there is continuity in the cable assembly.

c.Check continuity in both ends of the main cable assembly at pin #5.

d.If there is no continuity in the cable assembly at either pin, replace the cable assembly and retest. If there is continuity in the cable assembly at both pins and the relay resistor indicator is not lit, the console is inoperable and must be replaced.

5.Have your assistant step on the staircase (leave the console in the ATTRACT mode) while you check the field indicator light. It should be flickering. If it is and you still have a speed control problem, go to step #6.

If it is not flickering, ensure the following: the console cable is connected to the console; the console/main cable connection is secure; the connector at position J1 on the relay assembly circuit board is securely connected; that there is continuity in the cable assembly. To check for continuity:

Page 45

Image 52
Contents Stepmill Corporate Headquarters Willows Road N.E., Suite Kirkland, WA 800 425 Fax 425Warranty What is in this MANUAL? PrefaceContents Contents List of Tables AppendicesList of Illustrations Important Safety Instructions Safety GuidelinesSafety Guidelines Installation Instructions Dimensions and Specifications forPhysical Dimensions Power Supply SpecificationsRivnut Installation Instructions Basic Operating Instructions General Guidelines for Safe OperationLevel ∧ and Level ∨ to adjust your climbing speed Basic Instructions for First-Time UsersRest Periods Cool DownCorrect Exercise Position Feet Step squarely in the middle of each stepHeart Rate Input Heart Rate MonitoringLocked/Non-locked Option Error Messages Using the Transmitter Belt Telemetry Heart RateTelemetry Heart Rate Move closer to the consoleTransmitter Belt Maintaining the Transmitter Belt StairMasterPT Console Display WindowNumeric Keypad Entertainment KeypadIntensity Level Keys Stop KEY PromptWorkout Statistics Weight 175 lbs Exercise Program KeypadIntensity Level Quick Start ProgramAerobic Training Program Fat Burner ProgramSpeed Intervals Program Rest Interval Constant Heart Rate ProgramPT Console Maximal heart rate = 220 minus age low estimate IndividualsPretest Screening StairMaster Submaximal Fit TestPT Console StairMaster Fitness Protocol MEN WomenTurning on the Cpat Stair Climb Test Turning on the Nycfd Stair Climb TestConsole Codes Custom CodesQuick Scan Programming Machine Status Codes Resetting the Maintenance Hour Counter Configuration CodeMaintenance Instructions Maintenance RecordsHelpful Hints Tool ListPreventive Maintenance Initial ServiceCleaning and Inspecting Lubrication Maintenance Instructions Recommended Preventive Maintenance Schedule CleanerTroubleshooting General Troubleshooting GuidelinesTroubleshooting the Electrical System Console Fails to Power UpTroubleshooting the Electrical System Troubleshooting the Electrical System Console Diagnostic Tests Diagnostic CodesDisplay Test Keypad TestSerial Port Test Alternator TestError Reporting Tach TestTelemetry Polar Heart Rate Test Speed Control Problems Relay assembly circuit board Speed Control Problems Speed Control Problems Load Resistor Test Troubleshooting the Drive Train If the noise no longer exists, replace the alternatorCheck the step chain assemblies Check the step assembly Ensure the nuts at each step shaft end are tightParts Removal and Replacement CoversSide Covers Top CoverDisconnect the DC power cable Back CoverBottom Cover ConsoleDrive Chain POLY-V BeltRemove the left side cover Install the new drive chain by reversing the steps Step AssemblyStep shaft on both the upper Lower hinges of that step See Upper and lower step hingesStep Chain Assembly Remove the right and the left side coversLoosen the nuts on the pillow block bearing housing Upper and Lower Sprocket Assembly To reinstall the sprocket assembly Cable Assembly Reinstall the right side cover. Reconnect the DC power cable Transmission AssemblyAlternator Assembly RELAY/RESISTOR Assembly Parts Removal and Replacement Grounding Instructions Grounding SystemFCC Compliance Canadian DOC Class a ComplianceImportant Phone Numbers Figures Cover Fasteners Step Assembly Figures Sprocket AssembliesTransmission and Alternator Assemblies Wiring Diagram Relay Board