Stairmaster 7000 manual Check the step assembly, Ensure the nuts at each step shaft end are tight

Page 57

TROUBLESHOOTING THE DRIVE TRAIN

7.Check the condition of the upper and lower sprocket assemblies. Replace the sprocket assembly if it is worn excessively, has broken teeth, or if it is bent.

8.Check the alignment of the upper and the lower sprocket assemblies. The outside face of the upper and lower sprockets should be 1-11/16" (4.3 cm) from the outside edge of the left frame rail. Loosen the nuts on the pillow block bearing collars and tighten or loosen the bearing adjuster set screws until the distance to both sprockets is correct. Tighten the pillow block bearing nuts and verify the distance.

9.Check the step assembly.

a.Rotate the steps and check the hinges, step shafts, washers, and bearings (See Figure to Right) for wear, corrosion and lack of lubrication. Replace any worn parts.

b.Ensure the nuts at each step shaft end are tight.

Step Tread

Step Hinge

2 X Nut

 

4 X Washer

Step Shaft

2 X Bearing

 

10.Reinstall all parts. If the problem still exists, contact the Customer Service Department at 800-331-3578 for further assistance.

Page 50

Image 57
Contents Stepmill Willows Road N.E., Suite Kirkland, WA 800 425 Fax 425 Corporate HeadquartersWarranty Preface What is in this MANUAL?Contents Contents Appendices List of TablesList of Illustrations Safety Guidelines Important Safety InstructionsSafety Guidelines Dimensions and Specifications for Installation InstructionsPhysical Dimensions Power Supply SpecificationsRivnut Installation Instructions General Guidelines for Safe Operation Basic Operating InstructionsBasic Instructions for First-Time Users Level ∧ and Level ∨ to adjust your climbing speedCool Down Rest PeriodsFeet Step squarely in the middle of each step Correct Exercise PositionHeart Rate Monitoring Heart Rate InputLocked/Non-locked Option Error Messages Telemetry Heart Rate Using the Transmitter BeltTelemetry Heart Rate Move closer to the consoleStairMaster Transmitter Belt Maintaining the Transmitter BeltDisplay Window PT ConsoleEntertainment Keypad Numeric KeypadIntensity Level Keys Stop KEY PromptWorkout Statistics Exercise Program Keypad Weight 175 lbsIntensity Level Quick Start ProgramFat Burner Program Aerobic Training ProgramSpeed Intervals Program Constant Heart Rate Program Rest IntervalPT Console Individuals Maximal heart rate = 220 minus age low estimateStairMaster Submaximal Fit Test Pretest ScreeningPT Console StairMaster Fitness Protocol Women MENTurning on the Nycfd Stair Climb Test Turning on the Cpat Stair Climb TestCustom Codes Console CodesQuick Scan Programming Machine Status Codes Configuration Code Resetting the Maintenance Hour CounterMaintenance Records Maintenance InstructionsHelpful Hints Tool ListInitial Service Preventive MaintenanceCleaning and Inspecting Lubrication Maintenance Instructions Cleaner Recommended Preventive Maintenance ScheduleGeneral Troubleshooting Guidelines TroubleshootingTroubleshooting the Electrical System Console Fails to Power UpTroubleshooting the Electrical System Troubleshooting the Electrical System Diagnostic Codes Console Diagnostic TestsDisplay Test Keypad TestAlternator Test Serial Port TestTach Test Error ReportingTelemetry Polar Heart Rate Test Speed Control Problems Relay assembly circuit board Speed Control Problems Speed Control Problems Load Resistor Test If the noise no longer exists, replace the alternator Troubleshooting the Drive TrainCheck the step chain assemblies Ensure the nuts at each step shaft end are tight Check the step assemblyCovers Parts Removal and ReplacementSide Covers Top CoverBack Cover Disconnect the DC power cableBottom Cover ConsolePOLY-V Belt Drive ChainRemove the left side cover Step Assembly Install the new drive chain by reversing the stepsStep shaft on both the upper Lower hinges of that step See Upper and lower step hingesRemove the right and the left side covers Step Chain AssemblyLoosen the nuts on the pillow block bearing housing Upper and Lower Sprocket Assembly To reinstall the sprocket assembly Cable Assembly Transmission Assembly Reinstall the right side cover. Reconnect the DC power cableAlternator Assembly RELAY/RESISTOR Assembly Parts Removal and Replacement Grounding System Grounding InstructionsCanadian DOC Class a Compliance FCC ComplianceImportant Phone Numbers Figures Cover Fasteners Step Assembly Sprocket Assemblies FiguresTransmission and Alternator Assemblies Wiring Diagram Relay Board