THERMISTOR

Refer to page 4-7 for the procedure for servic- ing the thermistor.

The thermistor monitors the exhaust temper- ature. The changes in thermistor resistance signals the electronics control, which cycles the high-limit thermostat on and off to maintain the desired temperature.

1. Turn the dryer off but keep the electrical

8.Hold a glass bulb thermometer capable of reading from 32°C to 82°C (90°F to 180°F) in the center of the exhaust outlet. Mea- sure the exhaust temperatures with the heater on and off. The correct exhaust tem- peratures for the various settings are shown in the following chart.

TEMPERATURE

HEAT TURNS

HEAT TURNS

 

 

 

 

 

SETTING

OFF

ON

 

 

 

 

 

 

supply connected.

2.

Make sure that the dryer is empty and that

 

the lint screen is clean.

3.

Close the dryer door.

4.

Select Heavy Duty, Timed Dry, + or ,

 

Cycle End Signal (Loud), and Start.

5.

If error codes E1 or E2 flash on the dis-

 

play after 1 minute and the dryer turns off,

 

the thermistor, or the wire harness, is ei-

HIGH

68° C ±6°

 

(155° F ±10°)

 

 

 

MEDIUM

60° C ±6°

 

(140° F ±10°)

 

 

 

LOW

52° C ±6°

 

(125° F ±10°)

 

 

 

EXTRA

41° C ±3°

 

 

LOW

(105° F ±5°)

 

 

6 - 8°C

(10 - 15°F)

below the heat

turn off

temperature

 

ther shorted or open. Check the wire con-

 

nections at the thermistor or the electronic

 

control board. If wiring checks okay, re-

 

place the thermistor.

6.

If the dryer seems to operate normally, re-

 

move the exhaust vent and start the dryer.

7.

Select the desired temperature cycle to be

 

tested, and select 20 minutes of Timed Dry

 

heat using the + or – pushbuttons.

9.If the exhaust temperature is not within the specified limits, check the resistance of the thermistor, as shown in the following chart. If the resistance is okay, replace the elec- tronic control board.

THERMISTOR RESISTANCE

TEMP

RESISTANCE

TEMP

RESISTANCE

 

 

 

 

 

 

°C (°F)

(K ohms )

°C (°F)

(K ohms )

 

 

 

 

 

 

 

 

 

 

 

10° (50°)

19.9

43° (110°)

4.7

 

 

 

 

 

 

16° (60°)

15.3

49° (120°)

3.7

 

 

 

 

 

 

21° (70°)

11.9

54° (130°)

3.1

 

 

 

 

 

 

27° (80°)

9.2

60° (140°)

2.5

 

 

 

 

 

 

32° (90°)

7.4

66° (150° )

2.1

 

 

 

 

 

 

38°(100° )

5.7

71° (160° )

1.7

 

 

 

 

 

 

5-4

Image 53
Contents Epic Goals and Objectives ForwardTable of Contents Page General Safety FirstSerial Number Model & Serial Number DesignationsModel Number Model & Serial Number Label Tech Sheet Locations 12345 14367389 SpecificationsPurchased.9869374149893467762934899691241473393 12345included.12345467892649 527932759675445627927 1234546345 675794786 67846977 677 56457 123456782967455427646747276243454 For a grounded, cord-connected dryer 5766377275369#8 63#64456 648789123456 8567Into a hook shape 42Connect the other wires to outer terminal block screws 123456783933345678933 3333333333327643764732237426263346 6963747322374796 664663747322374743263747322374 32584 12324567289273835229322996 1232462345678834962 147 1234234922625 32343926253222 5672541234563789 428 75936969 5632879766977%%6&997969 Funnel Burner Gas Burner AssemblyComponent Locations Removing the Electronic Control Board Relay K1 P2 Removing the Console & Touchpad Subassembly Touchpad Subassembly Console Subpanel Catch Removing the Door Switch On the next To remove the thermal fuse or ther- mistorTo remove the drive motor To remove the belt switch To remove the heater To remove the high-limit thermostat or the thermal cutoff Removing the BELT, DRUM, & Rollers To remove the belt and drum To remove a roller Removing the Drum Light Socket Squeeze Arms Removing the Moisture Sensor To remove the burner assembly Manifold Clamp Screw To remove the high-limit thermostat To remove the flame sensorHeater Component TestingDrive Motor Thermal Fuse Thermistor Thermal Cutoff Electric Dryers only Resistance Tests Burner Ignitor GAS Burner CoilsHIGH-LIMIT Thermostat Flame SensorElectrostatic Discharge ESD Sensitive Electronics DiagnosticsDiagnostic Guide Activating The Diagnostic Test Mode Display FAULT/ERROR CodesDiagnostic Tests Diagnostic Moisture Sensor Diagnostic Console switches and indica- torsTroubleshooting Guide TroubleshootingTroubleshooting Tests Gas Dryers OnlyElectric Dryers Only Test #2 Motor Circuit Test Dryer does not heat Test #3 Heater TestTest #3a Thermistor Test Heat will not shut offTest #3c GAS Valve Test GAS Dryers only Test #3b Thermal Fuse TestTest #4 Moisture Sensor Test Test #3c Thermal Cutoff Test Electric Dryers onlyNone of the LEDs light up E3 error code is displayedParticular group of LEDs does not light up Single LED does not light upChecking The Button Functions If using a digital meter, the resistanceIf using an analog meter, the resis Checking The Rotary Cycle Selector Test #6 Door Switch TestPage Wiring Diagrams Page Product Specifications Warranty Information Sources