Whirlpool MED / GD 9600S, MED / GD 9700S manual Test #3 Heater Test, Dryer does not heat

Page 64

If belt switch is okay and there is still an open circuit, check and repair the wir- ing harness.

If the Start winding is in question and the resistance is much greater than 4 ohms, replace the motor.

9.Door switch problems can be found using the Diagnostic Tests on page 6-2; how- ever, if this was not done, the following (step 10) can be done without applying power to the dryer.

10.Connect the ohmmeter test leads to the electronic control board at P1-2, (neutral, white wire), and P1-3 (door, blue wire).

With the door closed, the ohmmeter should indicate a closed circuit (0 to 2 Ω). If not, replace the door switch assembly.

TEST #3: HEATER TEST

This test is performed when either of the fol- lowing situations occur:

Dryer does not heat

Heat will not shut off

This test checks the components making up the heating circuit. The following items are part of this system:

Harness/connection

Heater relay

Thermal fuse (gas dryer only)

Thermal cutoff (electric dryer only)

High-limit thermostat

Gas burner assembly (gas dryer only)

Heat element assembly (electric dryer only)

Centrifugal switch

Thermistor

Electronic control board

Console electronics & housing

Gas supply (gas dryer only)

Dryer does not heat:

1.Unplug dryer or disconnect power.

2.Remove the toe panel to access the ther- mal components.

3.Gas Dryers Only:

a)Perform TEST #3b (Thermal Fuse Test). If the thermal fuse is okay, proceed to step b.

b)Connect the ohmmeter test leads to the red wire and the blue wire of the high- limit thermostat.

If there is an open circuit, replace the high-limit thermostat.

Otherwise, proceed to step c.

c)Perform TEST #3c (Gas Valve Test). If this is okay, replace the electronic con- trol board.

High Limit Thermostat

Flame Sensor

Thermistor

Thermal Fuse

Continued on the next page.

6-7

Image 64
Contents Epic Forward Goals and ObjectivesTable of Contents Page Safety First GeneralModel Number Model & Serial Number DesignationsSerial Number Model & Serial Number Label Tech Sheet Locations Specifications 12345 14367389Purchased.9869374149893467762934899691241473393 12345included.12345467892649 1234546 527932759675445627927345 675794786 67846977 677 747276243454 12345678296745542764656457 5766377275 For a grounded, cord-connected dryer369#8 648 63#644568567 789123456Into a hook shape 42Connect the other wires to outer terminal block screws 33333333333 123456783933345678933743263747322374 6963747322374796 66466374732237427643764732237426263346 1232456728927383 3258412324 522932299662345678834962 12342 1473234392625 349226253222 5672541234563789 759 42836969 5632879766977%%6&997969 Component Locations Burner Gas Burner AssemblyFunnel Removing the Electronic Control Board Relay K1 P2 Removing the Console & Touchpad Subassembly Touchpad Subassembly Console Subpanel Catch Removing the Door Switch To remove the thermal fuse or ther- mistor On the nextTo remove the drive motor To remove the belt switch To remove the heater To remove the high-limit thermostat or the thermal cutoff Removing the BELT, DRUM, & Rollers To remove the belt and drum To remove a roller Removing the Drum Light Socket Squeeze Arms Removing the Moisture Sensor To remove the burner assembly Manifold Clamp Screw To remove the flame sensor To remove the high-limit thermostatComponent Testing HeaterDrive Motor Thermal Fuse Thermistor Thermal Cutoff Electric Dryers only Resistance Tests GAS Burner Coils Burner IgnitorFlame Sensor HIGH-LIMIT ThermostatDiagnostic Guide DiagnosticsElectrostatic Discharge ESD Sensitive Electronics Diagnostic Tests Display FAULT/ERROR CodesActivating The Diagnostic Test Mode Diagnostic Console switches and indica- tors Diagnostic Moisture SensorTroubleshooting Troubleshooting GuideTroubleshooting Tests Gas Dryers OnlyElectric Dryers Only Test #2 Motor Circuit Test Test #3 Heater Test Dryer does not heatHeat will not shut off Test #3a Thermistor TestTest #3b Thermal Fuse Test Test #3c GAS Valve Test GAS Dryers onlyTest #3c Thermal Cutoff Test Electric Dryers only Test #4 Moisture Sensor TestE3 error code is displayed None of the LEDs light upParticular group of LEDs does not light up Single LED does not light upIf using an analog meter, the resis If using a digital meter, the resistanceChecking The Button Functions Test #6 Door Switch Test Checking The Rotary Cycle SelectorPage Wiring Diagrams Page Product Specifications Warranty Information Sources