WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
FLAME SENSOR
Refer to page
1.Unplug dryer or disconnect power.
2.Turn off gas supply to dryer.
3.Disconnect the wire connectors from the flame sensor terminals.
4.Set the ohmmeter to the R X 1 scale.
5.Touch the ohmmeter test leads to the flame
sensor terminals. The meter should indi- cate a closed circuit (0 Ω).
HIGH-LIMIT THERMOSTAT
Refer to pages
1.Unplug dryer or disconnect power.
2.Turn off gas supply to dryer.
3.Disconnect the wire connectors from the
4.Set the ohmmeter to the R X 1 scale.
5.Touch the ohmmeter test leads to the high-
limit thermostat terminals. The meter should indicate a closed circuit (0 Ω).
Terminals
Thermostat
Flame Sensor
Terminals