Resistance Tests
Refer to page | 1. | Unplug dryer or disconnect power. | ||||
ing the door switch. | 2. | Turn off gas supply to dryer. | ||||
1. Go into the Diagnostic Test mode on page 6- | ||||||
3. | Close the dryer door. | |||||
2. The door switch function is verified with | ||||||
4. | Disconnect the | |||||
a beep each time the door is opened and | ||||||
| door switch to the electronic control board. | |||||
closed, and an alpha numeric code ap- |
| |||||
5. | Set the ohmmeter to the R X 1 scale. | |||||
pears in the display (“0E”, “0g”, “1E”, or | ||||||
Refer to the illustration below for the following | ||||||
“2E”). |
|
|
| |||
2. If any of the conditions are not met, or if | tests. | |||||
6. | Touch the black ohmmeter test lead to the | |||||
one of the dryer model codes listed above | ||||||
is displayed when the door is closed, check |
| white wire pin in the connector and leave | ||||
| it there for the remaining tests. | |||||
that the wires between the door switch and |
| |||||
7. | Touch the red ohmmeter test lead to the | |||||
the electronic control board are properly | ||||||
connected. |
|
|
|
| brown wire pin in the connector. The meter | |
If the wiring is okay, perform the resistance |
| should indicate an open circuit (infinite). | ||||
8. | Touch the red ohmmeter test lead to the | |||||
tests. | Door |
| Switch Connector | |||
|
|
| blue wire pin in the connector. The meter | |||
|
|
| ||||
|
|
|
|
| should indicate a closed circuit (0 ohms). | |
|
|
|
| 9. | Open the dryer door. | |
|
|
|
| 10. | Touch the red ohmmeter test lead to the | |
|
|
|
|
| blue wire pin in the connector. The meter | |
|
|
|
|
| should indicate an open circuit (infinite). | |
|
|
|
| 11. | Touch the red ohmmeter test lead to the | |
|
|
|
|
| brown wire pin in the connector. The meter | |
|
|
|
|
| should indicate a closed circuit (0 ohms). | |
|
|
|
| 12. | If the resistance test is incorrect, replace | |
|
|
|
|
| the wire and door switch assembly, (see | |
|
|
|
|
| page |