Whirlpool MED / GD 9700S, MED / GD 9600S manual Resistance Tests

Page 55
Door Switch
DOOR SWITCH

WARNING

Electrical Shock Hazard

Disconnect power before servicing.

Replace all parts and panels before operating.

Failure to do so can result in death or electrical shock.

Resistance Tests

Refer to page 4-6 for the procedure for servic-

1.

Unplug dryer or disconnect power.

ing the door switch.

2.

Turn off gas supply to dryer.

1. Go into the Diagnostic Test mode on page 6-

3.

Close the dryer door.

2. The door switch function is verified with

4.

Disconnect the 3-wire connector from the

a beep each time the door is opened and

 

door switch to the electronic control board.

closed, and an alpha numeric code ap-

 

5.

Set the ohmmeter to the R X 1 scale.

pears in the display (“0E”, “0g”, “1E”, or

Refer to the illustration below for the following

“2E”).

 

 

 

2. If any of the conditions are not met, or if

tests.

6.

Touch the black ohmmeter test lead to the

one of the dryer model codes listed above

is displayed when the door is closed, check

 

white wire pin in the connector and leave

 

it there for the remaining tests.

that the wires between the door switch and

 

7.

Touch the red ohmmeter test lead to the

the electronic control board are properly

connected.

 

 

 

 

brown wire pin in the connector. The meter

If the wiring is okay, perform the resistance

 

should indicate an open circuit (infinite).

8.

Touch the red ohmmeter test lead to the

tests.

Door

 

Switch Connector

 

 

 

blue wire pin in the connector. The meter

 

 

 

 

 

 

 

 

should indicate a closed circuit (0 ohms).

 

 

 

 

9.

Open the dryer door.

 

 

 

 

10.

Touch the red ohmmeter test lead to the

 

 

 

 

 

blue wire pin in the connector. The meter

 

 

 

 

 

should indicate an open circuit (infinite).

 

 

 

 

11.

Touch the red ohmmeter test lead to the

 

 

 

 

 

brown wire pin in the connector. The meter

 

 

 

 

 

should indicate a closed circuit (0 ohms).

 

 

 

 

12.

If the resistance test is incorrect, replace

 

 

 

 

 

the wire and door switch assembly, (see

 

 

 

 

 

page 4-6 for the procedure), and retest.

5-6

Image 55
Contents Epic Goals and Objectives ForwardTable of Contents Page General Safety FirstModel Number Model & Serial Number DesignationsSerial Number Model & Serial Number Label Tech Sheet Locations 12345 14367389 SpecificationsPurchased.9869374149893467762934899691241473393 12345included.12345467892649 527932759675445627927 1234546345 675794786 67846977 677 747276243454 12345678296745542764656457 For a grounded, cord-connected dryer 5766377275369#8 63#64456 648789123456 8567Into a hook shape 42Connect the other wires to outer terminal block screws 123456783933345678933 33333333333743263747322374 6963747322374796 66466374732237427643764732237426263346 32584 12324567289273835229322996 1232462345678834962 147 12342567254 323439262534922625 32221234563789 5632 759428 36969879766977%%6&997969 Component Locations Burner Gas Burner AssemblyFunnel Removing the Electronic Control Board Relay K1 P2 Removing the Console & Touchpad Subassembly Touchpad Subassembly Console Subpanel Catch Removing the Door Switch On the next To remove the thermal fuse or ther- mistorTo remove the drive motor To remove the belt switch To remove the heater To remove the high-limit thermostat or the thermal cutoff Removing the BELT, DRUM, & Rollers To remove the belt and drum To remove a roller Removing the Drum Light Socket Squeeze Arms Removing the Moisture Sensor To remove the burner assembly Manifold Clamp Screw To remove the high-limit thermostat To remove the flame sensorHeater Component TestingDrive Motor Thermal Fuse Thermistor Thermal Cutoff Electric Dryers only Resistance Tests Burner Ignitor GAS Burner CoilsHIGH-LIMIT Thermostat Flame SensorDiagnostic Guide DiagnosticsElectrostatic Discharge ESD Sensitive Electronics Diagnostic Tests Display FAULT/ERROR CodesActivating The Diagnostic Test Mode Diagnostic Moisture Sensor Diagnostic Console switches and indica- torsGas Dryers Only TroubleshootingTroubleshooting Guide Troubleshooting TestsElectric Dryers Only Test #2 Motor Circuit Test Dryer does not heat Test #3 Heater TestTest #3a Thermistor Test Heat will not shut offTest #3c GAS Valve Test GAS Dryers only Test #3b Thermal Fuse TestTest #4 Moisture Sensor Test Test #3c Thermal Cutoff Test Electric Dryers onlySingle LED does not light up E3 error code is displayedNone of the LEDs light up Particular group of LEDs does not light upIf using an analog meter, the resis If using a digital meter, the resistanceChecking The Button Functions Checking The Rotary Cycle Selector Test #6 Door Switch TestPage Wiring Diagrams Page Product Specifications Warranty Information Sources