Checking The Rotary Cycle Selector

Using the following table, check the resistance at each cycle setting.

When using a digital meter, touch the “+” ohmmeter test lead to P1-14, and leave it there during the tests. Touch the other test lead to the test points indi- cated in the chart.

When using an analog meter, touch the “–” ohmmeter test lead to P1-14, and leave it there during the tests. Touch the other test lead to the test points indi- cated in the chart.

TEST #6: DOOR SWITCH TEST

Go into the Diagnostic Test mode on page 6-2. The door switch function is verified with a beep each time the door is opened and closed, and an alpha numeric code appears in the display (“0E”, “0g”, “1E”, or “2E”).

If any of the conditions are not met, or if one of the dryer model codes listed above is displayed when the door is closed, check that the wires between the door switch and the electronic con- trol board are properly connected.

If the connections are okay, replace the door switch assembly and its wiring, and retest.

If the door switch assembly and wiring have been replaced and dryer still does not start, replace the electronic control board.

Cycle

Digital Meter + Lead On P1-14

Analog Meter – Lead On P1-14

 

 

 

 

 

 

 

 

 

 

Selection

P1-11

P1-10

P1-9

P1-8

P1-11

P1-10

 

P1-9

P1-8

 

 

 

 

 

 

 

 

 

 

 

 

 

Heavy Duty

 

 

 

 

 

 

 

 

 

 

 

 

 

Timed Dry

3.5 MΩ

 

3.5 MΩ

30 - 40 kΩ

10

- 20 kΩ

 

 

 

 

 

 

 

 

 

 

 

Touch Up

 

3.5 MΩ

10

- 20 kΩ

 

 

 

 

 

 

 

 

 

 

 

Rapid Dry

 

3.5 MΩ

1.59 MΩ

10

- 20 kΩ

10 - 20 kΩ

 

 

 

 

 

 

 

 

 

 

 

Super

1.58

MΩ

290 kΩ

10 - 20 kΩ

 

10 - 20 kΩ

Delicate

 

 

 

 

 

 

 

 

 

 

 

Delicate

3.5 MΩ

290 kΩ

290 kΩ

10 - 20 kΩ

10 - 20 kΩ

 

10 - 20 kΩ

 

 

 

 

 

 

 

 

 

 

 

Casual

3.5 MΩ

 

290 kΩ

30 - 40 kΩ

 

10 - 20 kΩ

 

 

 

 

 

 

 

 

 

 

 

Normal

 

290 kΩ

 

10 - 20 kΩ

 

 

 

 

 

 

 

 

 

 

 

• = Infinite

6-13

Image 70
Contents Epic Forward Goals and ObjectivesTable of Contents Page Safety First GeneralModel Number Model & Serial Number DesignationsSerial Number Model & Serial Number Label Tech Sheet Locations Specifications 12345 14367389Purchased.9869374149893467762934899691241473393 12345included.12345467892649 1234546 527932759675445627927345 675794786 67846977 677 747276243454 12345678296745542764656457 5766377275 For a grounded, cord-connected dryer369#8 648 63#644568567 789123456Into a hook shape 42Connect the other wires to outer terminal block screws 33333333333 123456783933345678933743263747322374 6963747322374796 66466374732237427643764732237426263346 1232456728927383 3258412324 522932299662345678834962 12342 1473222 323439262534922625 5672541234563789 36969 759428 5632879766977%%6&997969 Component Locations Burner Gas Burner AssemblyFunnel Removing the Electronic Control Board Relay K1 P2 Removing the Console & Touchpad Subassembly Touchpad Subassembly Console Subpanel Catch Removing the Door Switch To remove the thermal fuse or ther- mistor On the nextTo remove the drive motor To remove the belt switch To remove the heater To remove the high-limit thermostat or the thermal cutoff Removing the BELT, DRUM, & Rollers To remove the belt and drum To remove a roller Removing the Drum Light Socket Squeeze Arms Removing the Moisture Sensor To remove the burner assembly Manifold Clamp Screw To remove the flame sensor To remove the high-limit thermostatComponent Testing HeaterDrive Motor Thermal Fuse Thermistor Thermal Cutoff Electric Dryers only Resistance Tests GAS Burner Coils Burner IgnitorFlame Sensor HIGH-LIMIT ThermostatDiagnostic Guide DiagnosticsElectrostatic Discharge ESD Sensitive Electronics Diagnostic Tests Display FAULT/ERROR CodesActivating The Diagnostic Test Mode Diagnostic Console switches and indica- tors Diagnostic Moisture SensorTroubleshooting Tests TroubleshootingTroubleshooting Guide Gas Dryers OnlyElectric Dryers Only Test #2 Motor Circuit Test Test #3 Heater Test Dryer does not heatHeat will not shut off Test #3a Thermistor TestTest #3b Thermal Fuse Test Test #3c GAS Valve Test GAS Dryers onlyTest #3c Thermal Cutoff Test Electric Dryers only Test #4 Moisture Sensor TestParticular group of LEDs does not light up E3 error code is displayedNone of the LEDs light up Single LED does not light upIf using an analog meter, the resis If using a digital meter, the resistanceChecking The Button Functions Test #6 Door Switch Test Checking The Rotary Cycle SelectorPage Wiring Diagrams Page Product Specifications Warranty Information Sources