Whirlpool MED / GD 9700S Checking The Button Functions, If using a digital meter, the resistance

Page 69

Checking The Button Functions

Before replacing the electronic control board, check for proper button function as follows:

Unplug dryer or disconnect power.

Disconnect the ribbon cables at P3 and P4 on the electronic control board. The illustration below shows the connector locations.

Using an ohmmeter, touch the meter test leads to the ribbon cable connector pin locations in- dicated in the table. Press the associated but- ton and measure resistance.

NOTE: The meter must be connected with the proper polarity. For most analog meters, the connection polarity is opposite that of digital meters.

If using a digital meter, the resistance

reading should go from infinity down to approximately 1 to 3.5 MΩ (megohms). If available, you can use the “diode test” function on the digital meter.

If using an analog meter, the resis-

tance reading should go from infinity (open circuit) to less than 40 kΩ. If not, reverse the polarity of the meter con-

nection, and measure the resistance again. If the reading is less than 40 kΩ, the circuit is okay, and you should con- tinue the remainder of the resistance checks with the connections reversed from that indicated in the table.

Button

Digital

Meter

Analog

Meter

+ Lead

– Lead

– Lead

+ Lead

 

 

 

 

 

TEMP

P3-12

P3-8

P3-12

P3-8

EXTRA CARE

P3-13

P3-8

P3-13

P3-8

 

 

 

 

 

DRYNESS

P3-14

P3-7

P3-14

P3-7

LEVEL

 

 

 

 

+

P3-13

P3-7

P3-13

P3-7

P3-12

P3-7

P3-12

P3-7

 

 

 

 

 

CYCLE END

P3-12

P4-2

P3-12

P4-2

SIGNAL

 

 

 

 

HOLD TO

P3-14

P4-2

P3-14

P4-2

START

 

 

 

 

OFF/Pause

P3-13

P4-2

P3-13

P4-2

CONTROL ON

P3-12

P3-9

P3-12

P3-9

 

 

 

 

 

White Blue

Light Blue

Motor Relay

Heater Relay

Black

Lt. Blue Black

 

Red/White

Green/Yellow

Black

 

 

N.O.

Open

Yellow/Red

COM

Rev X

 

XXXXXXX

Code YDDD

P/N

Date

6-12

Image 69
Contents Epic Goals and Objectives ForwardTable of Contents Page General Safety FirstModel & Serial Number Designations Model NumberSerial Number Model & Serial Number Label Tech Sheet Locations 12345 14367389 SpecificationsPurchased.9869374149893467762934899691241473393 12345included.12345467892649 527932759675445627927 1234546345 675794786 67846977 677 123456782967455427646 74727624345456457 For a grounded, cord-connected dryer 5766377275369#8 63#64456 648789123456 8567Into a hook shape 42Connect the other wires to outer terminal block screws 123456783933345678933 333333333336963747322374796 664663747322374 74326374732237427643764732237426263346 32584 12324567289273835229322996 1232462345678834962 147 1234234922625 32343926253222 5672541234563789 428 75936969 5632879766977%%6&997969 Burner Gas Burner Assembly Component LocationsFunnel Removing the Electronic Control Board Relay K1 P2 Removing the Console & Touchpad Subassembly Touchpad Subassembly Console Subpanel Catch Removing the Door Switch On the next To remove the thermal fuse or ther- mistorTo remove the drive motor To remove the belt switch To remove the heater To remove the high-limit thermostat or the thermal cutoff Removing the BELT, DRUM, & Rollers To remove the belt and drum To remove a roller Removing the Drum Light Socket Squeeze Arms Removing the Moisture Sensor To remove the burner assembly Manifold Clamp Screw To remove the high-limit thermostat To remove the flame sensorHeater Component TestingDrive Motor Thermal Fuse Thermistor Thermal Cutoff Electric Dryers only Resistance Tests Burner Ignitor GAS Burner CoilsHIGH-LIMIT Thermostat Flame SensorDiagnostics Diagnostic GuideElectrostatic Discharge ESD Sensitive Electronics Display FAULT/ERROR Codes Diagnostic TestsActivating The Diagnostic Test Mode Diagnostic Moisture Sensor Diagnostic Console switches and indica- torsTroubleshooting Guide TroubleshootingTroubleshooting Tests Gas Dryers OnlyElectric Dryers Only Test #2 Motor Circuit Test Dryer does not heat Test #3 Heater TestTest #3a Thermistor Test Heat will not shut offTest #3c GAS Valve Test GAS Dryers only Test #3b Thermal Fuse TestTest #4 Moisture Sensor Test Test #3c Thermal Cutoff Test Electric Dryers onlyNone of the LEDs light up E3 error code is displayedParticular group of LEDs does not light up Single LED does not light upIf using a digital meter, the resistance If using an analog meter, the resisChecking The Button Functions Checking The Rotary Cycle Selector Test #6 Door Switch TestPage Wiring Diagrams Page Product Specifications Warranty Information Sources