Whirlpool 8577208 Make Electrical Connection, Power Supply Cord Method U.S. Only

Page 11

(not the air cycle), let the dryer run for at least five minutes. Dryer will stop when time is used up.

NOTE: Dryer door must be closed for dryer to operate. When door is open, dryer stops, but timer continues to run. To restart dryer, close door and push START/RESTART button.

4.If the burner does not ignite and you can feel no heat inside the dryer, shut off dryer for five minutes. Check that all supply valve controls are in “ON” position and that the electrical cord is plugged in. Repeat five-minute test.

5.If drying time is too long, make sure lint screen is clean.

INSTALLATION INSTRUCTIONS – ELECTRIC DRYER

Install Coin Slide and Coin Box

The console houses the factory-installed accumulator timer with actuating arm and button.

The factory-installed timer is set to provide 45 minutes (4 pins) of drying time when activated by the coin slide. Timer cams for 30-minute (6 pins) and 60-minute (3 pins) drying times are included in the parts bag.

The coin slide mechanism, control panel lock and key, and coin box lock and key are not included and are available from usual industry sources.

WARNING

Excessive Weight Hazard

Use two or more people to move and install dryer. Failure to do so can result in back or other injury.

NOTE: Slide dryer onto cardboard or hardboard before moving to avoid damaging floor covering.

1.Using two or more people, move dryer to desired installation location.

2.Take tape off front corners of dryer. Open dryer and remove the literature and parts packages. Wipe the interior of the drum thoroughly with a damp cloth.

3.Take two of the cardboard corners from the carton and place them on the floor in back of the dryer. Firmly grasp the body of the dryer and gently lay it on its back on the cardboard corners.

4.With one of the legs in hand, check the ridges for a diamond marking. That's how far the leg is supposed to go into the hole.

5.Start to screw the leveling legs into the holes by hand. (Use a small amount of liquid detergent to lubricate the screw threads so it is easier to turn the legs.) Use a 1-inch wrench or socket wrench to finish turning the legs until you reach the diamond mark.

Now stand the dryer up.

6.Remove the service door of the meter case by lifting it up at the back. Install the money-accepting device. (Refer to manufacturer's instructions for proper installation.)

7.Replace the meter case service door. Put the coin vault with lock and key in the meter case opening.

8.Remove cardboard or hardboard from under dryer.

Make Electrical Connection

Power Supply Cord Method – U.S. Only

This dryer is manufactured with the neutral ground wire connected to the neutral (center) of the wiring harness at the terminal block. If local codes do not permit this type of connection, use “Four-wire connection” instructions.

Use a UL-listed power supply cord rated 240-volt min., 30-amp and marked for use with a clothes dryer.

WARNING

Fire Hazard

Use a new UL listed 30 amp power supply cord.

Use a UL listed strain relief.

Disconnect power before making electrical connections.

Connect neutral wire (white or center wire) to center terminal (silver).

Ground wire (green or bare wire) must be connected to green ground connector.

Connect remaining 2 supply wires to remaining 2 terminals (gold).

Securely tighten all electrical connections.

Failure to do so can result in death, fire, or electrical shock.

1.Disconnect power.

For dryers using coin slides, use the adapter kit supplied with the dryer.

11

Image 11
Contents 8577208 Table of Contents/Table des matièresDryer Safety What to do if YOU Smell GAS Tools needed Recessed Area and Closet Installation InstructionsTools and Parts Location RequirementsRecessed front view Product Dimensions 27 68.6 cm dryerProduct Dimensions 29 73.7 cm dryer Minimum Installation ClearancesRecommended Ground Method Electrical Requirements Gas DryerElectrical Requirements Electric Dryer For a grounded, cord-connected dryer Gas Supply RequirementsType of Gas Gas Supply Line Gas Supply Pressure TestingVenting Requirements If an exhaust hood cannot be used Do not install screening or cap over the end of the ventVent System Length Multiple Dryer Venting Maximum Vent LengthConnect Vent Install Coin Slide and Coin BoxComplete Installation Make Electrical Connection Power Supply Cord Method U.S. OnlyRemove hold-down screw and the terminal block cover Power Supply Cord, Four-wire electrical connectionEDC Power Supply Cord, Three-wire electrical connectionDirect Wire Four-wire electrical connection Direct Wire Method U.S. OnlyLoosen or remove the center terminal block screw Direct Wire Three-wire electrical connectionChanging to a 30- or 60-MINUTE Timing CAM If you need assistance Maintenance instructionsIf dryer does not operate check the following Page Sécurité DE LA Sécheuse Importantes Instructions DE Sécurité Pièces fournies Exigences d’emplacementOutillage et pièces Outillage nécessaireDimensions du produit Sécheuse de 29 73,7 cm Dimensions du produit Sécheuse de 27 68,6 cmSpécifications électriques sécheuse électrique Méthode recommandée de liaison à la terreSpécifications électriques sécheuse à gaz Spécifications de l’alimentation en gaz Tests de pressurisation de la canalisation de gaz Exigences concernant l’évacuationType de gaz Canalisation de gazLongueur maximale du conduit Longueur du circuit dévacuationÉvacuation multiple de la sécheuse Si une bouche de décharge ne peut être utilisée Installation dune glissière et Dune caisse à monnaieRaccordement du conduit d’évacuation Achever l’installationRaccordement à la canalisation de gaz Déconnecter la source de courant électrique Installation d’une glissière et d’une Caisse à monnaieRaccordement électrique Méthode du cordon d’alimentation É.-U. seulementÔter la vis de retenue et le couvercle du bloc de connexion Cordon d’alimentation, prise de courant à quatre conducteursCordon d’alimentation, prise de courant à trois conducteurs Câblage direct, prise de courant à quatre conducteurs Méthode de câblage direct É.-U. seulementTrois conducteurs avec conducteur de liaison Câblage direct, prise de courant à trois conducteursInstallation D’UNE Came DE Minutage Pour 30 OU 60 Minutes Si vous avez besoin d’aide Instructions d’entretienSi la sécheuse ne fonctionne pas, vérifier ce qui suit 8577208