Whirlpool 8577208 installation instructions Changing to a 30- or 60-MINUTE Timing CAM

Page 16

CHANGING TO A 30- OR 60-MINUTE TIMING CAM

WARNING

Electrical Shock Hazard

Disconnect power before making cam changes.

Failure to follow these instructions can result in death or electrical shock.

You can install the 30-minute or 60-minute timing cam (shipped with dryer) as follows:

1.Unplug dryer or disconnect power.

2.Unlock meter case.

3.Turn the timing cam by hand until the V-shaped notch lines up below the ratchet tooth.

AB

C

D

A. Ratchet tooth

B. Timing cam

C. Drive lug

D. V-shaped notch

4.Insert a narrow, flat-blade screwdriver under the timing cam near the clock shaft. Gently lift cam straight up and off shaft making sure that the V-shaped notch clears the ratchet tooth.

5.Place new cam (hub side down) over clock shaft. Line up flat side of shaft with flat side of cam hole. Check that drive lug is in place.

6.Turn cam until V-shaped notch lines up with ratchet tooth.

7.Press cam down in place on motor shaft. Make sure that V-shaped notch clears the ratchet tooth.

8.Close and lock the meter case.

16

Image 16
Contents Table of Contents/Table des matières 8577208Dryer Safety What to do if YOU Smell GAS Recessed Area and Closet Installation Instructions Tools and PartsLocation Requirements Tools neededProduct Dimensions 27 68.6 cm dryer Product Dimensions 29 73.7 cm dryerMinimum Installation Clearances Recessed front viewElectrical Requirements Electric Dryer Electrical Requirements Gas DryerRecommended Ground Method Type of Gas Gas Supply RequirementsFor a grounded, cord-connected dryer Venting Requirements Gas Supply Pressure TestingGas Supply Line Do not install screening or cap over the end of the vent Vent System Length Multiple Dryer VentingMaximum Vent Length If an exhaust hood cannot be usedComplete Installation Install Coin Slide and Coin BoxConnect Vent Power Supply Cord Method U.S. Only Make Electrical ConnectionPower Supply Cord, Four-wire electrical connection Remove hold-down screw and the terminal block coverPower Supply Cord, Three-wire electrical connection EDCDirect Wire Method U.S. Only Direct Wire Four-wire electrical connectionDirect Wire Three-wire electrical connection Loosen or remove the center terminal block screwChanging to a 30- or 60-MINUTE Timing CAM If dryer does not operate check the following Maintenance instructionsIf you need assistance Page Sécurité DE LA Sécheuse Importantes Instructions DE Sécurité Exigences d’emplacement Outillage et piècesOutillage nécessaire Pièces fourniesDimensions du produit Sécheuse de 27 68,6 cm Dimensions du produit Sécheuse de 29 73,7 cmSpécifications électriques sécheuse à gaz Méthode recommandée de liaison à la terreSpécifications électriques sécheuse électrique Spécifications de l’alimentation en gaz Exigences concernant l’évacuation Type de gazCanalisation de gaz Tests de pressurisation de la canalisation de gazÉvacuation multiple de la sécheuse Longueur du circuit dévacuationLongueur maximale du conduit Installation dune glissière et Dune caisse à monnaie Si une bouche de décharge ne peut être utiliséeRaccordement à la canalisation de gaz Achever l’installationRaccordement du conduit d’évacuation Installation d’une glissière et d’une Caisse à monnaie Raccordement électriqueMéthode du cordon d’alimentation É.-U. seulement Déconnecter la source de courant électriqueCordon d’alimentation, prise de courant à quatre conducteurs Ôter la vis de retenue et le couvercle du bloc de connexionCordon d’alimentation, prise de courant à trois conducteurs Méthode de câblage direct É.-U. seulement Câblage direct, prise de courant à quatre conducteursCâblage direct, prise de courant à trois conducteurs Trois conducteurs avec conducteur de liaisonInstallation D’UNE Came DE Minutage Pour 30 OU 60 Minutes Si la sécheuse ne fonctionne pas, vérifier ce qui suit Instructions d’entretienSi vous avez besoin d’aide 8577208