22INSTALLATION INSTRUCTIONS
Connecting electric dryers (cont.) USA only
wWarning
•Connect the power cord to the terminal block. Connec teach power cord wire to the terminal block screw that has the same colored wire. For example, connect the black power cord wire to the terminal block screw with the black wire. Failure to follow these instructions may result in a short, overload, fire or death.
•Grounding through the neutral conductor is prohibited for: (1) new
(3) recreational vehicles, and (4) areas where local codes prohibit grounding through the neutral conductor.
Four-wire connection for electric dryers:
Power cord
•A
•A
1.Remove the terminal block access cover on the upper back of the dryer. Install a
Terminal
Block
Strain Relief |
•Use a 30 A, 240 V,
2.Transfer the dryer’s ground wire from behind the green ground screw to the center screw of the terminal block. Attach the two hot leads of the power cord to the outer terminal block screws. Attach the white neutral wire to the center terminal block screw. Attach the power cord ground wire to the green ground screw. Tighten alL screws securely. Reinstall the terminal block access cover.
Hot | Neutral |
(Black) | (White) |
| Hot |
Ground | (Red) |
| |
Screw |
|
| White Wire |
| moved from |
Power Cord | Ground Screw |
| |
Ground Wire |
|