LG Electronics DLE1101W Connecting electric dryers cont. USA only, UL-Listed Wire Power Cord

Page 22

22INSTALLATION INSTRUCTIONS

Connecting electric dryers (cont.) USA only

wWarning

Connect the power cord to the terminal block. Connec teach power cord wire to the terminal block screw that has the same colored wire. For example, connect the black power cord wire to the terminal block screw with the black wire. Failure to follow these instructions may result in a short, overload, fire or death.

Grounding through the neutral conductor is prohibited for: (1) new branch-circuit installations, (2) mobile homes,

(3) recreational vehicles, and (4) areas where local codes prohibit grounding through the neutral conductor.

Four-wire connection for electric dryers:

Power cord

A 4-wire connection is required for all mobile and manufactured home installations, as well as all new construction after January 1, 1996.

A UL-listed strain relief is required.

1.Remove the terminal block access cover on the upper back of the dryer. Install a UL-listed strain relief into the power cord through-hole; then thread a UL-listed, 30 A, 240 V, 4-wire, #10 AWG-minimum copper conductor power cord through the strain relief.

Terminal

Block

UL-Listed

Strain Relief

Use a 30 A, 240 V, UL-listed power cord with #10 AWG- minimum copper conductor and closed loop or forked terminals with upturned ends.

2.Transfer the dryer’s ground wire from behind the green ground screw to the center screw of the terminal block. Attach the two hot leads of the power cord to the outer terminal block screws. Attach the white neutral wire to the center terminal block screw. Attach the power cord ground wire to the green ground screw. Tighten alL screws securely. Reinstall the terminal block access cover.

Hot

Neutral

(Black)

(White)

 

Hot

Ground

(Red)

 

Screw

 

 

White Wire

 

moved from

Power Cord

Ground Screw

 

Ground Wire

 

UL-Listed

4-Wire Power

Cord

Image 22
Contents DrYer No El2001JProtocol P154 Special FeaturesSanitization Performance of Residential Clothes dryer Important Safety Instructions This is the safety alert symbolBasic Safety Precautions Safety Instructions for Installation Exhaust/Ducting Failure to do so can result in electric shock or injury Table of Contents Parts Optional accessoriesIntroducing Your Dryer Drying rack Sold separatelyControl panel features Display Cycle Completion Indicator with Check Filter ReminderFlow Sense Duct Blockage Sensing System Indicator Custom ProgramLeveling the dryer Installation InstructionsPreview installation order Press and holdClearances Installation location requirementsSide of the dryer. See Connecting electric dryers See Venting the dryerRecommended installation spacing for cabinet installation Leveling the dryerHinge screw Reversing the doorSwing Door Option 2 Bottom Venting Installing the side vent kitOption 1 Side Venting Adapter Duct Bracket KnockoutVenting the dryer Correct Venting Routing and Connecting DuctworkIncorrect Venting Failure to do so can result in fire, explosion, or death Connecting gas dryersElectrical requirements for gas models only Connect the dryer to the type of gas shown on the nameplateHigh-altitude installations Connecting the gas supplyElectrical connection Connecting electric dryers Electrical requirements for electric models onlyFour-wire connection for electric dryers Power cord Connecting electric dryers cont. USA onlyUL-Listed Wire Power Cord Four-wire connection for electric dryers Direct wire Use UL-listed4-wire #10 AWG-minimum copper conductor cableThree-wire connection for electric dryers Power cord Three-wire connection for electric dryers Direct wire Use UL-listed3-wire #10 AWG-minimum copper conductor cableElectric Models Final installation checkGAS Models Gas dryer must be permanently attached to the floorEnd of cycle Installation test Duct checkCheck the display for results Press START/PAUSE buttonPS or PF or nP Restricted or blocked airflowTE1 or tE2 Check the duct conditionSelect a Cycle Operating the dryer3TURN on the Dryer Begin CycleManual dry cycles Cycle guideSensor dry cycles Certified by NSFLoading the dryer Sorting loadCheck the lint filter before every load To Add Cycle Options to a Cycle Cycle setting buttons Special functionsCustom program To Save a Custom ProgramMaintenance Regular cleaningTroubleshooting Before calling for serviceSpecifications Using Smartdiagnosistm SmartdiagnosisWarranty Period HOW Service is Handled Page Secadora Características Especiales Panel DE Control Fácil Para UsarInstrucciones Importantes DE Seguridad Estas palabras significanNo altere los controles Instrucciones DE Conexión a Tierra Instrucciones Importantes parapara la instalación Guarde Estas Instrucciones Tabla de contenidos Accesorios opcionales PartesSecado en parrilla Adquirido por separado Programa Botón Cycles Características del panel de controlBotones DE MÁS TIEMPO/MENOS Tiempo More TIME/LESS Time Pantalla DE Tiempo Y EstadoRecordatorio DE Verificar Filtro Check Filter Reminder PantallaEstimated Time Remaining Programa Personalizado Custom ProgramVista previa del orden de instalación Instrucciones Para LA InstalaciónPulse y mantenga Un lugar que permita la instalación correcta del sistema de Requisitos del lugar de instalaciónEspacios de instalación Exterior. Consulte Requisitos de ventilaciónNivelación de la secadora Inversion de la puerta Opción 2 Ventilación inferior Instalación del kit de ventilación lateralOpción 1 Ventilación lateral Codo 11/2Cónexión del conducto de ventilación de la secadora Correcta Conexión del conducto de ventilación de la secadoraVentilación de escape IncorrectaConexión de secadoras a gas Requisitos eléctricos para modelos a gas únicamenteInstalaciones en lugares de gran altitud Conexión del suministro de gasConexión eléctrica Conector flexible de aceroRequisitos eléctricos únicamente para modelos eléctricos Cómo conectar las secadoras eléctricas cont. Sólo EE.UU Cómo conectar las secadoras eléctricas Se requiere un protector de tensión listado por ULNeutro Negro Haga los finales de los 3 cables en forma de gancho Modelos a GAS Revisión de instalación finalModelos Eléctricos Fin del ciclo Test de Instalación conducto de comprobarObserve la pantalla para conocer el resultado Pulse el botón INICIO/PAUSASTART/PAUSEPS o PF o nP Flujo de aire restringido o bloqueadoTE1 o tE2 Compruebe las condiciones del conductoEncender LA Secadora Cómo UsarFuncionamiento de la secadora Seleccionar UN CicloCiclos de secado manual manual dry Guía de ciclosCiclos de secado con sensor sensor dry Certificado por NSFRevise el filtro de pelusa antes de cada uso Clasificación de cargasCómo cargar la secadora Funciones especiales Botones de ajuste de ciclosPrograma personalizado Mantenimiento Limpieza regularResoluciÓn de problemas Antes de llamar a mantenimientoEspecificaciones Utilización del SmartDiagnosis Llame al 1-800-243-0000 y escoja la opción adecuada Período DE Garantía Cómo SE Administra EL MantenimientoMantenimiento en el hogar In-Home Más cercanoPage Español Page Español Canada