20INSTALLATION INSTRUCTIONS
Connecting gas dryers (cont.)
wWarning
To reduce the risk of fire, electric shock, or injury to persons when using this appliance, follow basic precautions, including the following:
•Installation and service must be performed by a qualified installer, service agency, or the gas supplier. Failure to do so can result in fire, explosion, or death.
•Use only a new stainless steel flexible connector and a new
•A gas shutoff valve must be installed within 6 ft. (1.8 m) of the dryer. Failure to do so can result in fire, explosion, or death.
•The dryer is configured for Natural Gas when shipped from the factory. Make sure that the dryer is equipped with the correct burner orifice for the type of gas being used (Natural Gas or Liquefied Petroleum). Failure to do so can result in fire, explosion, or death.
•If necessary, the correct orifice (for the LP, orifice kit order part number 383EEL3002D) should be installed by a qualified technician and the change should be noted on the dryer. Failure to do so can result in fire, explosion, or death.
•All connections must be in accordance with local codes and regulations. Failure to do so can result in fire, explosion, or death.
•Gas dryers MUST exhaust to the outdoors. Failure to do so can result in fire, explosion, or death.
Connecting the gas supply
1.Make sure that the gas supply to the laundry room is turned
OFF. Confirm that the type of gas available in your laundry room is appropriate for the dryer. The dryer is prepared for Natural Gas with a 3⁄₈ - inch NPT gas connection.
2.Remove the shipping cap from the gas connection at the back of the dryer. Be careful not to damage the threads of the gas connector when removing the shipping cap.
3.Connect the dryer to your laundry room’s gas supply using a new flexible stainless steel connector with a 3⁄₈ - inch NPT fitting.
4.Securely tighten all connections between the dryer and your laundry room’s gas supply. Turn on your laundry room’s gas supply and check all pipe connections (both internal and external) for gas leaks with a noncorrosive
Electrical connection
Plug dryer into a 120 VAC,
60 Hz grounded
3/8” NPT Gas | 1/8” NPT Pipe |
Plug | |
Connection | Gas Supply |
| |
Shutoff Valve | |
Stainless Steel Flexible |
|
Connector |
|
High-altitude installations
The BTU rating of this dryer is
If your gas dryer is being installed at an elevation above 10,000 feet, it must be derated by a qualified technician or gas supplier.