LG Electronics DLG1102W, DLE1101W Three-wire connection for electric dryers Direct wire

Page 25

INSTALLATION INSTRUCTIONS 25

Connecting electric dryers (cont.) USA only

wWarning

Connect the power cord to the terminal block. Connect each power cord wire to the terminal block screw that has the same colored wire. For example, connect the black power cord wire to the terminal block screw with the black wire. Failure to follow these instructions may result in a short, overload, fire or death.

Grounding through the neutral conductor is prohibited for: (1) new branch-circuit installations, (2) mobile homes,

(3) recreational vehicles, and (4) areas where local codes prohibit grounding through the neutral conductor.

Three-wire connection for electric dryers: Direct wire

A 3-wire connection is NOT permitted on new construction after January 1, 1996.

A UL-listed strain relief is required.

1.Remove 31inches (8.9 cm) of the outer covering from the wire. Strip 1 inch (2.5 cm) insulation from each wire. Bend the ends of the three wires into a hook shape.

1" (2.5 cm)

2.Remove the terminal block access cover on the upper back of the dryer. Install a UL-listed strain relief into the power cord through-hole; then thread the power cable prepared in Step 1 through the strain relief.

Terminal

Block

UL-Listed

Strain Relief

UL-Listed

3-Wire Power

Cord

Use UL-listed3-wire #10 AWG-minimum copper conductor cable.

Allow at least 5 ft. (1.5 m) length to allow for removal and reinstallation of the dryer.

3.Attach the two hot leads of the power cord to the outer terminal block screws. Attach the neutral wire to the center terminal block screw. Connect the external ground (if required by local codes) to the green ground screw. Tighten all screws securely. Reinstall the terminal block access cover.

Hot

Neutral

 

(Black)

(White)

Hot

Ground

 

 

(Red)

Screw

 

 

 

White Wire from Dryer harness

External Ground Wire (If required by local codes)

ENGLISH

Image 25
Contents No El2001J DrYerProtocol P154 Special FeaturesSanitization Performance of Residential Clothes dryer This is the safety alert symbol Important Safety InstructionsBasic Safety Precautions Safety Instructions for Installation Exhaust/Ducting Failure to do so can result in electric shock or injury Table of Contents Introducing Your Dryer Optional accessoriesParts Drying rack Sold separatelyControl panel features Flow Sense Duct Blockage Sensing System Indicator Cycle Completion Indicator with Check Filter ReminderDisplay Custom ProgramPreview installation order Installation InstructionsLeveling the dryer Press and holdSide of the dryer. See Connecting electric dryers Installation location requirementsClearances See Venting the dryerLeveling the dryer Recommended installation spacing for cabinet installationHinge screw Reversing the doorSwing Door Option 1 Side Venting Installing the side vent kitOption 2 Bottom Venting Adapter Duct Bracket KnockoutVenting the dryer Correct Venting Routing and Connecting DuctworkIncorrect Venting Electrical requirements for gas models only Connecting gas dryersFailure to do so can result in fire, explosion, or death Connect the dryer to the type of gas shown on the nameplateHigh-altitude installations Connecting the gas supplyElectrical connection Electrical requirements for electric models only Connecting electric dryers Four-wire connection for electric dryers Power cord Connecting electric dryers cont. USA only UL-Listed Wire Power Cord Use UL-listed4-wire #10 AWG-minimum copper conductor cable Four-wire connection for electric dryers Direct wireThree-wire connection for electric dryers Power cord Use UL-listed3-wire #10 AWG-minimum copper conductor cable Three-wire connection for electric dryers Direct wireGAS Models Final installation checkElectric Models Gas dryer must be permanently attached to the floorCheck the display for results Installation test Duct checkEnd of cycle Press START/PAUSE buttonTE1 or tE2 Restricted or blocked airflowPS or PF or nP Check the duct condition3TURN on the Dryer Operating the dryerSelect a Cycle Begin CycleSensor dry cycles Cycle guideManual dry cycles Certified by NSFLoading the dryer Sorting loadCheck the lint filter before every load Custom program Cycle setting buttons Special functionsTo Add Cycle Options to a Cycle To Save a Custom ProgramRegular cleaning MaintenanceBefore calling for service TroubleshootingSpecifications Smartdiagnosis Using SmartdiagnosistmWarranty Period HOW Service is Handled Page Secadora Panel DE Control Fácil Para Usar Características EspecialesEstas palabras significan Instrucciones Importantes DE SeguridadNo altere los controles Instrucciones DE Conexión a Tierra Instrucciones Importantes parapara la instalación Guarde Estas Instrucciones Tabla de contenidos Accesorios opcionales PartesSecado en parrilla Adquirido por separado Botones DE MÁS TIEMPO/MENOS Tiempo More TIME/LESS Time Características del panel de controlPrograma Botón Cycles Pantalla DE Tiempo Y EstadoEstimated Time Remaining PantallaRecordatorio DE Verificar Filtro Check Filter Reminder Programa Personalizado Custom ProgramVista previa del orden de instalación Instrucciones Para LA InstalaciónPulse y mantenga Espacios de instalación Requisitos del lugar de instalaciónUn lugar que permita la instalación correcta del sistema de Exterior. Consulte Requisitos de ventilaciónNivelación de la secadora Inversion de la puerta Opción 1 Ventilación lateral Instalación del kit de ventilación lateralOpción 2 Ventilación inferior Codo 11/2Cónexión del conducto de ventilación de la secadora Ventilación de escape Conexión del conducto de ventilación de la secadoraCorrecta IncorrectaRequisitos eléctricos para modelos a gas únicamente Conexión de secadoras a gasConexión eléctrica Conexión del suministro de gasInstalaciones en lugares de gran altitud Conector flexible de aceroRequisitos eléctricos únicamente para modelos eléctricos Cómo conectar las secadoras eléctricas cont. Sólo EE.UU Se requiere un protector de tensión listado por UL Cómo conectar las secadoras eléctricasNeutro Negro Haga los finales de los 3 cables en forma de gancho Modelos a GAS Revisión de instalación finalModelos Eléctricos Observe la pantalla para conocer el resultado Test de Instalación conducto de comprobarFin del ciclo Pulse el botón INICIO/PAUSASTART/PAUSETE1 o tE2 Flujo de aire restringido o bloqueadoPS o PF o nP Compruebe las condiciones del conductoFuncionamiento de la secadora Cómo UsarEncender LA Secadora Seleccionar UN CicloCiclos de secado con sensor sensor dry Guía de ciclosCiclos de secado manual manual dry Certificado por NSFRevise el filtro de pelusa antes de cada uso Clasificación de cargasCómo cargar la secadora Funciones especiales Botones de ajuste de ciclosPrograma personalizado Limpieza regular MantenimientoAntes de llamar a mantenimiento ResoluciÓn de problemasEspecificaciones Utilización del SmartDiagnosis Mantenimiento en el hogar In-Home Período DE Garantía Cómo SE Administra EL MantenimientoLlame al 1-800-243-0000 y escoja la opción adecuada Más cercanoPage Español Page Español Canada