INSTALLATION INSTRUCTIONS 25
Connecting electric dryers (cont.) USA only
wWarning
•Connect the power cord to the terminal block. Connect each power cord wire to the terminal block screw that has the same colored wire. For example, connect the black power cord wire to the terminal block screw with the black wire. Failure to follow these instructions may result in a short, overload, fire or death.
•Grounding through the neutral conductor is prohibited for: (1) new
(3) recreational vehicles, and (4) areas where local codes prohibit grounding through the neutral conductor.
Three-wire connection for electric dryers: Direct wire
•A
•A
1.Remove 31⁄₂ inches (8.9 cm) of the outer covering from the wire. Strip 1 inch (2.5 cm) insulation from each wire. Bend the ends of the three wires into a hook shape.
1" (2.5 cm)
2.Remove the terminal block access cover on the upper back of the dryer. Install a
Terminal
Block
Strain Relief
Cord
•Use UL-listed 3-wire #10 AWG-minimum copper conductor cable.
•Allow at least 5 ft. (1.5 m) length to allow for removal and reinstallation of the dryer.
3.Attach the two hot leads of the power cord to the outer terminal block screws. Attach the neutral wire to the center terminal block screw. Connect the external ground (if required by local codes) to the green ground screw. Tighten all screws securely. Reinstall the terminal block access cover.
Hot | Neutral |
|
(Black) | (White) | Hot |
Ground |
| |
| (Red) | |
Screw |
| |
|
|
White Wire from Dryer harness
External Ground Wire (If required by local codes)