LG Electronics DLE1101W, DLG1102W owner manual Exhaust/Ducting

Page 6

6IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS

READ ALL INSTRUCTIONS BEFORE USE

wWarning

For your safety, the information in this manual must be followed to minimize the risk of fire or explosion, electric shock, or to prevent property damage, injury to persons, or death.

SAFETY INSTRUCTIONS FOR INSTALLATION

wWarning

To reduce the risk of injury to persons, follow all industry recommended safety procedures including the use of long sleeved gloves and safety glasses. Failure to follow all of the safety warnings in this manual could result in property damage, injury to persons, or death.

Exhaust/Ducting:

Gas dryers MUST be exhausted to the outside. Failure to follow these instructions can result in fire or death.

The dryer exhaust system must be exhausted to the outside of the dwelling. If the dryer is not exhausted outdoors, some fine lint and large amounts of moisture will be expelled into the laundry area. An accumulation of lint in any area of the home can create a health and fire hazard.

Use only rigid metal or flexible metal 4-inch diameter ductwork inside the dryer cabinet or for exhausting to the outside. Use of plastic or other combustible ductwork can cause a fire. Punctured ductwork can cause a fire if it collapses or becomes otherwise restricted in use or during installation.

Ductwork is not provided with the dryer, and you should obtain the necessary ductwork locally. The end cap should have hinged dampers to prevent backdraft when the dryer is not in use. Failure to follow these instructions can result in fire or death.

The exhaust duct must be 4 inches (10.2 cm) in diameter with no obstructions. The exhaust duct should be kept as short as possible. Make sure to clean any old ducts before installing your new dryer. Failure to follow these instructions can result in fire or death.

Rigid or semi-rigid metal ducting is recommended for use between the dryer and the wall. In special installations when it is impossible to make a connection with the above recommendations, a UL-listed flexible metal transition duct may be used between the dryer and wall connection only. The use of this ducting will affect drying time. Failure to follow these instructions can result in fire or death.

DO NOT use sheet metal screws or other fasteners which extend into the duct that could catch lint and reduce the efficiency of the exhaust system. Secure all joints with duct tape. For complete details, follow the Installation Instructions. Failure to follow these instructions can result in fire or death.

Image 6
Contents DrYer No El2001JSpecial Features Protocol P154Sanitization Performance of Residential Clothes dryer Important Safety Instructions This is the safety alert symbolBasic Safety Precautions Safety Instructions for Installation Exhaust/Ducting Failure to do so can result in electric shock or injury Table of Contents Parts Optional accessoriesIntroducing Your Dryer Drying rack Sold separatelyControl panel features Display Cycle Completion Indicator with Check Filter ReminderFlow Sense Duct Blockage Sensing System Indicator Custom ProgramLeveling the dryer Installation InstructionsPreview installation order Press and holdClearances Installation location requirementsSide of the dryer. See Connecting electric dryers See Venting the dryerRecommended installation spacing for cabinet installation Leveling the dryerReversing the door Hinge screwSwing Door Option 2 Bottom Venting Installing the side vent kitOption 1 Side Venting Adapter Duct Bracket KnockoutVenting the dryer Routing and Connecting Ductwork Correct VentingIncorrect Venting Failure to do so can result in fire, explosion, or death Connecting gas dryersElectrical requirements for gas models only Connect the dryer to the type of gas shown on the nameplateConnecting the gas supply High-altitude installationsElectrical connection Connecting electric dryers Electrical requirements for electric models onlyConnecting electric dryers cont. USA only Four-wire connection for electric dryers Power cordUL-Listed Wire Power Cord Four-wire connection for electric dryers Direct wire Use UL-listed4-wire #10 AWG-minimum copper conductor cableThree-wire connection for electric dryers Power cord Three-wire connection for electric dryers Direct wire Use UL-listed3-wire #10 AWG-minimum copper conductor cableElectric Models Final installation checkGAS Models Gas dryer must be permanently attached to the floorEnd of cycle Installation test Duct checkCheck the display for results Press START/PAUSE buttonPS or PF or nP Restricted or blocked airflowTE1 or tE2 Check the duct conditionSelect a Cycle Operating the dryer3TURN on the Dryer Begin CycleManual dry cycles Cycle guideSensor dry cycles Certified by NSFSorting load Loading the dryerCheck the lint filter before every load To Add Cycle Options to a Cycle Cycle setting buttons Special functionsCustom program To Save a Custom ProgramMaintenance Regular cleaningTroubleshooting Before calling for serviceSpecifications Using Smartdiagnosistm SmartdiagnosisWarranty Period HOW Service is Handled Page Secadora Características Especiales Panel DE Control Fácil Para UsarInstrucciones Importantes DE Seguridad Estas palabras significanNo altere los controles Instrucciones DE Conexión a Tierra Instrucciones Importantes parapara la instalación Guarde Estas Instrucciones Tabla de contenidos Partes Accesorios opcionalesSecado en parrilla Adquirido por separado Programa Botón Cycles Características del panel de controlBotones DE MÁS TIEMPO/MENOS Tiempo More TIME/LESS Time Pantalla DE Tiempo Y EstadoRecordatorio DE Verificar Filtro Check Filter Reminder PantallaEstimated Time Remaining Programa Personalizado Custom ProgramInstrucciones Para LA Instalación Vista previa del orden de instalaciónPulse y mantenga Un lugar que permita la instalación correcta del sistema de Requisitos del lugar de instalaciónEspacios de instalación Exterior. Consulte Requisitos de ventilaciónNivelación de la secadora Inversion de la puerta Opción 2 Ventilación inferior Instalación del kit de ventilación lateralOpción 1 Ventilación lateral Codo 11/2Cónexión del conducto de ventilación de la secadora Correcta Conexión del conducto de ventilación de la secadoraVentilación de escape IncorrectaConexión de secadoras a gas Requisitos eléctricos para modelos a gas únicamenteInstalaciones en lugares de gran altitud Conexión del suministro de gasConexión eléctrica Conector flexible de aceroRequisitos eléctricos únicamente para modelos eléctricos Cómo conectar las secadoras eléctricas cont. Sólo EE.UU Cómo conectar las secadoras eléctricas Se requiere un protector de tensión listado por ULNeutro Negro Haga los finales de los 3 cables en forma de gancho Revisión de instalación final Modelos a GASModelos Eléctricos Fin del ciclo Test de Instalación conducto de comprobarObserve la pantalla para conocer el resultado Pulse el botón INICIO/PAUSASTART/PAUSEPS o PF o nP Flujo de aire restringido o bloqueadoTE1 o tE2 Compruebe las condiciones del conductoEncender LA Secadora Cómo UsarFuncionamiento de la secadora Seleccionar UN CicloCiclos de secado manual manual dry Guía de ciclosCiclos de secado con sensor sensor dry Certificado por NSFClasificación de cargas Revise el filtro de pelusa antes de cada usoCómo cargar la secadora Botones de ajuste de ciclos Funciones especialesPrograma personalizado Mantenimiento Limpieza regularResoluciÓn de problemas Antes de llamar a mantenimientoEspecificaciones Utilización del SmartDiagnosis Llame al 1-800-243-0000 y escoja la opción adecuada Período DE Garantía Cómo SE Administra EL MantenimientoMantenimiento en el hogar In-Home Más cercanoPage Español Page Español Canada