Equator MD3720CEE Unit keeps filling only when the unit is switched on, No tumble action

Page 10

regulator and the wire M1 on the motor connector, if there is no continuity, the wash timer is bad, check the continuity between terminals 3 & 4 on the speed regulator if there is continuity then the speed regulator is bad or else the Wash timer is bad.

12)Unit won’t spin in cycles: Normal / Casual / Quick / Delicate / Wool

a)Motor: See Testing of motor.

b)Speed Regulator / Wash Timer: Set the wash timer to the position one click away from the off position for the Normal cycle. Check the continuity between terminal#1 on Speed regulator and the wire M1 on the motor connector, if there is no continuity, the wash timer is bad, check the continuity between terminals 4 & 5 on the speed regulator if there is continuity then the speed regulator is bad or else the Wash timer is bad.

13) Unit keeps filling only when the unit is switched on

a)Pressure switch: Unplug the unit. With excessive water still in tub, check for continuity between terminals 31 and 32. Replace pressure switch if test indicates continuity.

b)Motor: Remove the motor connector and check if the water is still filling in, if no the motor is bad.

14) Clothes wet at the end of wash cycle

a)Water in tub: See Won't drain.

b)Inadequate final spin: See Won't Spin.

DRY CYCLE (MD 3720 CEE / MD 1720 V) ◊

1) No tumble action

a)No power input: Check that cord is plugged in, and circuit breaker or, if fuse is OK. Test unit power switch.

b)Door not closed: Close door firmly, so that it latches tightly.

c)Belt: Check belt and adjust tension.

2) Clothes cold and damp at the end of dry cycle

a)No Heat coming into the drum: Check the Fuse Link according to the instructions in Appendix A and replace if necessary.

b)Timer not advanced beyond the cool-down period: Set dryer timer for times longer than 15 minutes.

c)Thermostats open: Check for continuity between the terminals, at room temperature.

d)Thermal fuse open: Check for continuity.

e)Heating element: Check resistance: 25 ohms maximum.

f)Fan Motor / Dry Timer: Set a 30 minutes cycle on the dryer knob keeping the washer knob on off position. Check for 115V AC across the two terminals of the fan motor, if present and the fan motor is not operating, the fan motor is bad or else the dryer timer is bad provided no part on the heater housing is receiving 115V AC.

10

Image 10
Contents Combo Washer Dryer # Table of Contents # Warranty Information Safe Servicing Practices Installation MD 3720 CEE Important Preservice Instructions Water leaking from door Machine vibrating or vibrating noiseUnit wont fill Unit is noisy Unit fills, won’t agitate / tumbleUnit won’t drain out water Unit VibratesWater fill in tub with unit off Timer doesn’t advanceWater leaks from detergent drawer Unit overfillsNo tumble action Unit keeps filling only when the unit is switched onClothes wet at the end of wash cycle Clothes cold and damp at the end of dry cycleClothes hot and damp at the end of dry cycle Long Drying TimeReplacement Procedure, Wiring & Testing of Parts Power Switch 52799 Replacement ProcedureDoor Switch / Door Lock 00750 Replacement Procedure Pressure Switch 50774 Replacement Procedure Cold water valve 10820 Replacement Procedure Hot TestHot water valve 00821 Replacement Procedure Wash Timer 50819 Replacement Procedure Dry Timer 50728 Replacement Procedure Cold TestHalf Load Switch 51799 Replacement Procedure Half Heat Switch 50799 Replacement Procedure Fusible Link / Wire with fuse 00807 Replacement Procedure Wiring Fusible LinkThermostat 00808 Replacement Procedure FEXFan Motor 50732 Replacement Procedure Blower / Fan / Impeller Assembly 51733 Replacement Procedure Heating Element 00745 Replacement Procedure Speed Regulator 00791 Replacement Procedure Drain Pump 00776 Replacement Procedure Main Motor 50751 Replacement Procedure Quick Check Appliance Desk