5)Hot water valve (00821) Replacement Procedure:
▪
▪
▪
▪
▪
▪
Unplug the unit.
Remove the top panel (Two screws behind and slide back)
Unfix the two screws at the back which hold the hot water valve.(Marked H) Remove the clamp to the hose.
Replace with the new valve and do the wiring as before / below. Fix all the parts back by following the reverse procedure.
Wiring: Hot water Valve
EVC
EVCX
Testing Procedure:
▪Hot Test:
1)Set the washer knob to the Towels / Sheets position and switch on the unit.
2)You should get 115V AC between the terminals EVCX & EVC and the unit should start filling in with water, it the unit does not start filling the valve is bad.
ePlease Note: The door should be locked properly and there should be enough pressure to the water supply.