5)Hot water valve (00821) Replacement Procedure:

Unplug the unit.

Remove the top panel (Two screws behind and slide back)

Unfix the two screws at the back which hold the hot water valve.(Marked H) Remove the clamp to the hose.

Replace with the new valve and do the wiring as before / below. Fix all the parts back by following the reverse procedure.

Wiring: Hot water Valve

EVC

EVCX

Testing Procedure:

Hot Test:

1)Set the washer knob to the Towels / Sheets position and switch on the unit.

2)You should get 115V AC between the terminals EVCX & EVC and the unit should start filling in with water, it the unit does not start filling the valve is bad.

ePlease Note: The door should be locked properly and there should be enough pressure to the water supply.

16

Image 16
Contents Combo Washer Dryer # Table of Contents # Warranty Information Safe Servicing Practices Installation MD 3720 CEE Important Preservice Instructions Water leaking from door Machine vibrating or vibrating noiseUnit wont fill Unit fills, won’t agitate / tumble Unit won’t drain out waterUnit is noisy Unit VibratesTimer doesn’t advance Water leaks from detergent drawerWater fill in tub with unit off Unit overfillsUnit keeps filling only when the unit is switched on Clothes wet at the end of wash cycleNo tumble action Clothes cold and damp at the end of dry cycleClothes hot and damp at the end of dry cycle Long Drying TimeReplacement Procedure, Wiring & Testing of Parts Power Switch 52799 Replacement ProcedureDoor Switch / Door Lock 00750 Replacement Procedure Pressure Switch 50774 Replacement Procedure Cold water valve 10820 Replacement Procedure Hot TestHot water valve 00821 Replacement Procedure Wash Timer 50819 Replacement Procedure Dry Timer 50728 Replacement Procedure Cold TestHalf Load Switch 51799 Replacement Procedure Half Heat Switch 50799 Replacement Procedure Fusible Link / Wire with fuse 00807 Replacement Procedure Wiring Fusible LinkThermostat 00808 Replacement Procedure FEXFan Motor 50732 Replacement Procedure Blower / Fan / Impeller Assembly 51733 Replacement Procedure Heating Element 00745 Replacement Procedure Speed Regulator 00791 Replacement Procedure Drain Pump 00776 Replacement Procedure Main Motor 50751 Replacement Procedure Quick Check Appliance Desk