Equator MD3720CEE service manual Replacement Procedure, Wiring & Testing of Parts

Page 12

Replacement Procedure, Wiring & Testing of Parts

1)Power Switch (52799) Replacement Procedure:

Unplug the unit.

Remove the top panel (Two screws behind and slide back)

Pull out the soap dispenser, plastic washer knob and dryer knob. Remove the control panel. (3 Screws)

Pull out the plastic switch cover for the power switch.

Pull out the power switch by matching the grooves in the panel pushing the switch towards the back.

Replace with the new switch and do the wiring as before / below. Fix all the parts back by following the reverse procedure.

Wiring: Power switch - bottom view

111

1

2

113

3

4

112

114

Testing Procedure:

Cold Test:

1)When the Power button is pushed in – There will be continuity between the connectors

1 & 3, 2 & 4.

12

Image 12
Contents Combo Washer Dryer # Table of Contents # Warranty Information Safe Servicing Practices Installation MD 3720 CEE Important Preservice Instructions Machine vibrating or vibrating noise Water leaking from doorUnit wont fill Unit fills, won’t agitate / tumble Unit won’t drain out waterUnit is noisy Unit VibratesTimer doesn’t advance Water leaks from detergent drawerWater fill in tub with unit off Unit overfillsUnit keeps filling only when the unit is switched on Clothes wet at the end of wash cycleNo tumble action Clothes cold and damp at the end of dry cycleClothes hot and damp at the end of dry cycle Long Drying TimeReplacement Procedure, Wiring & Testing of Parts Power Switch 52799 Replacement ProcedureDoor Switch / Door Lock 00750 Replacement Procedure Pressure Switch 50774 Replacement Procedure Cold water valve 10820 Replacement Procedure Hot TestHot water valve 00821 Replacement Procedure Wash Timer 50819 Replacement Procedure Dry Timer 50728 Replacement Procedure Cold TestHalf Load Switch 51799 Replacement Procedure Half Heat Switch 50799 Replacement Procedure Fusible Link / Wire with fuse 00807 Replacement Procedure Wiring Fusible LinkThermostat 00808 Replacement Procedure FEXFan Motor 50732 Replacement Procedure Blower / Fan / Impeller Assembly 51733 Replacement Procedure Heating Element 00745 Replacement Procedure Speed Regulator 00791 Replacement Procedure Drain Pump 00776 Replacement Procedure Main Motor 50751 Replacement Procedure Quick Check Appliance Desk